• 제목/요약/키워드: bearing capacity calculation

검색결과 110건 처리시간 0.022초

Shear mechanism and bearing capacity calculation on steel reinforced concrete special-shaped columns

  • Xue, J.Y.;Chen, Z.P.;Zhao, H.T.;Gao, L.;Liu, Z.Q.
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.473-487
    • /
    • 2012
  • An experimental study was performed to investigate the seismic performance of steel reinforced concrete (SRC) special-shaped columns. For this purpose, 17 steel reinforced concrete special-shaped column specimens under low-cyclic reversed load were tested, load process and failure patterns of the specimens with different steel reinforcement were observed. The test results showed that the failure patterns of these columns include shear-diagonal compression failure, shear-bond failure, shear-flexure failure and flexural failure. The failure mechanisms and characteristics of SRC special-shaped columns were also analyzed. For different SRC special-shaped columns, based on the failure characteristics and mechanism observed from the test, formulas for calculating ultimate shear capacity in shear-diagonal compression failure and shear-bond failure under horizontal axis and oblique load were derived. The calculated results were compared with the test results. Both the theoretical analysis and the experimental results showed that, the shear capacity of T, L shaped columns under oblique load are larger than that under horizontal axis load, whereas the shear capacity of +-shaped columns under oblique load are less than that under horizontal axis load.

변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 II-축 경사도 영향 (Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part II - Shaft Misalignment Effect)

  • 전상명;장시열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.305-310
    • /
    • 2001
  • Within some degree of journal misalignment, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined under the condition of variable density and specific heat. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the effects of variable density and specific heat on shaft misalignment are significant in determining the load capacity of a journal bearing operating at high speed.

  • PDF

Effect of hybrid fibers on flexural performance of reinforced SCC symmetric inclination beams

  • Zhang, Cong;Li, Zhihua;Ding, Yining
    • Computers and Concrete
    • /
    • 제22권2호
    • /
    • pp.209-220
    • /
    • 2018
  • In order to evaluate the effect of hybrid fibers on the flexural performance of tunnel segment at room temperature, twelve reinforced self-consolidating concrete (SCC) symmetric inclination beams containing steel fiber, macro polypropylene fiber, micro polypropylene fiber, and their hybridizations were studied under combined loading of flexure and axial compression. The results indicate that the addition of mono steel fiber and hybrid fibers can enhance the ultimate bearing capacity and cracking behavior of tested beams. These improvements can be further enhanced along with increasing the content of steel fiber and macro PP fiber, but reduced with the increase of the reinforcement ratio of beams. The hybrid effect of steel fiber and macro PP fiber was the most obvious. However, the addition of micro PP fibers led to a degradation to the flexural performance of reinforced beams at room temperature. Meanwhile, the hybrid use of steel fiber and micro polypropylene fiber didn't present an obvious improvement to SCC beams. Compared to micro polypropylene fiber, the macro polypropylene fiber plays a more prominent role on affecting the structural behavior of SCC beams. A calculation method for ultimate bearing capacity of flexural SCC symmetric inclination beams at room temperature by taking appropriate effect of hybrid fibers into consideration was proposed. The prediction results using the proposed model are compared with the experimental data in this study and other literature. The results indicate that the proposed model can estimate the ultimate bearing capacity of SCC symmetric inclination beams containing hybrid fibers subjected to combined action of flexure and axial compression at room temperature.

CPR 공법의 압축재하시험을 통한 기초지반의 보강효과 (Effect of CPR Foundation Reinforcement Assessed by Compressive Loading Tests)

  • 강성승;김정한;노정두;고진석
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.211-222
    • /
    • 2019
  • 본 연구는 CPR 공법을 적용한 압축재하시험을 통하여 지반의 항복하중과 허용지지력을 평가하여 기초 지반 보강효과를 확인하기 위한 것이다. 주입재의 평균압축강도는 계획된 강도보다 높게 나타났다. 또한 각 지층에서 표준관입시험 결과는 시험 전보다 시험 후의 평균 N값이 향상되었다. 즉, 이것은 지반의 지지력을 증대시키는 효과를 가져왔음을 의미한다. 두 종류의 CPR 말뚝 압축재하시험 결과에 의하면, 최대 재하하중에 의한 전침하량과 순침하량은 CPR 말뚝직경 허용범위를 초과하는 침하량을 나타냈다. 침하량 기준과 하중-침하량 곡선에 의해 산정한 항복하중 및 허용지지력은 적용되는 방법에 따라 값의 편차가 크게 나타났다. 따라서 허용지지력은 다양한 항복하중 산정법을 적용한 후 종합적인 분석을 통하여 최적의 값을 결정할 필요성이 있다고 사료된다.

Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups

  • Ke, Xiaojun;Ding, Wen;Liao, Dingguo
    • Advances in concrete construction
    • /
    • 제12권5호
    • /
    • pp.399-409
    • /
    • 2021
  • The existing method to improve the coordination performance of the inner and outer parts of concrete-encased concrete-filled steel tube (CFST) composite columns by increasing the volume-stirrup ratio causes difficulties in construction due to over-dense stirrups. Thus, this paper proposes an open polygonal composite stirrup with high strength and high ductility CRB600H reinforced rebar, and seventeen specimens were constructed, and their axial compressive performance was tested. The main parameters considered were the volume-stirrup ratio, the steel tube size, the stirrup type and the stirrup strength. The test results indicated: For the specimens restrained by open octagonal composite stirrups, compared with the specimen of 0.5% volume-stirrup ratio, the compressive bearing capacity increased by 14.6%, 15.7% and 21.5% for volume-stirrup ratio of 0.73%, 1.07% and 1.61%, respectively. For the specimens restrained by open composite rectangle stirrups, compared with the specimen of 0.79% volume-stirrup ratio, the compressive bearing capacity increased by 7.5%, 6.1%, and -1.4% for volume-stirrup ratio of 1.12%, 1.58% and 2.24%, respectively. The restraint ability and the bearing capacity of the octagonal composite stirrup are better than other stirrup types. The specimens equipped with open polygonal composite stirrup not only had a higher ductility than those with the traditional closed-loop stirrup, but they also had a higher axial bearing capacity than those with an HPB300 strength grades stirrup. Therefore, the open composite stirrup can be used in practical engineering. A new calculation method was proposed based on the stress-strain models for confined concrete under different restrain conditions, and the predicted value was close to the experimental value.

Shear mechanism of steel fiber reinforced concrete deep coupling beams

  • Li, Kou;Zhao, Jun;Ren, Wenbo
    • Structural Engineering and Mechanics
    • /
    • 제73권2호
    • /
    • pp.143-152
    • /
    • 2020
  • Deep coupling beams are more prone to suffer brittle shear failure. The addition of steel fibers to seismic members such as coupling beams can improve their shear performance and ductility. Based on the test results of steel fiber reinforced concrete(SFRC) coupling beams with span-to-depth ratio between 1.5 and 2.5 under lateral reverse cyclic load, the shear mechanism were analyzed by using strut-and-tie model theory, and the effects of the span-to-depth ratio, compressive strength and volume fraction of steel fiber on shear strengths were also discussed. A simplified calculation method to predict the shear capacity of SFRC deep coupling beams was proposed. The results show that the shear force is mainly transmitted by a strut-and-tie mechanism composed of three types of inclined concrete struts, vertical reinforcement ties and nodes. The influence of span-to-depth ratio on shear capacity is mainly due to the change of inclination angle of main inclined struts. The increasing of concrete compressive strength or volume fraction of steel fiber can improve the shear capacity of SFRC deep coupling beams mainly by enhancing the bearing capacity of compressive struts or tensile strength of the vertical tie. The proposed calculation method is verified using experimental data, and comparative results show that the prediction values agree well with the test ones.

Mechanical behaviour of composite columns composed of RAC-filled square steel tube and profile steel under eccentric compression loads

  • Ma, Hui;Xi, Jiacheng;Zhao, Yaoli;Dong, Jikun
    • Steel and Composite Structures
    • /
    • 제38권1호
    • /
    • pp.103-120
    • /
    • 2021
  • This research examines the eccentric compression performance of composite columns composed of recycled aggregate concrete (RAC)-filled square steel tube and profile steel. A total of 17 specimens on the composite columns with different recycled coarse aggregate (RCA) replacement percentage, RAC strength, width to thickness ratio of square steel tube, profile steel ratio, eccentricity and slenderness ratio were subjected to eccentric compression tests. The failure process and characteristic of specimens under eccentric compression loading were observed in detail. The load-lateral deflection curves, load-train curves and strain distribution on the cross section of the composite columns were also obtained and described on the basis of test data. Results corroborate that the failure characteristics and modes of the specimens with different design parameters were basically similar under eccentric compression loads. The compression side of square steel tube yields first, followed by the compression side of profile steel. Finally, the RAC in the columns was crushed and the apparent local bulging of square steel tube was also observed, which meant that the composite column was damaged and failed. The composite columns under eccentric compression loading suffered from typical bending failure. Moreover, the eccentric bearing capacity and deformation of the specimens decreased as the RCA replacement percentage and width to thickness ratio of square steel tube increased, respectively. Slenderness ratio and eccentricity had a significantly adverse effect on the eccentric compression performance of composite columns. But overall, the composite columns generally had high-bearing capacity and good deformation. Meanwhile, the mechanism of the composite columns under eccentric compression loads was also analysed in detail, and the calculation formulas on the eccentric compression capacity of composite columns were proposed via the limit equilibrium analysis method. The calculation results of the eccentric compression capacity of columns are consistent with the test results, which verify the validity of the formulas, and the conclusions can serve as references for the engineering application of this kind of composite columns.

패드의 탄성변형을 고려한 공기윤활 틸팅패드 저어널 베어링의 윤활해석에 관한 연구 (A Study on the Lubrication Analysis of Air-Lubricated Tilting Pad Journal Bearing with Pad Elasticity Effect)

  • 황평;양승한;윤성진
    • Tribology and Lubricants
    • /
    • 제12권1호
    • /
    • pp.29-35
    • /
    • 1996
  • The static and dynamic stability analysis of air-lubriceted tilting pad journal bearing which considers tilting effect of each pad and preload but neglects pad inertia were performed. And these characteristic analysis were performed with elasticity effect too. A direct numerical method is used in calculating the static characteristics such as load carrying capacity, firction force and perturbation method is used for calculation of dynamic characteristics. The stability analysis was performed with the variation of bearing number, eccentricity ratio and attitude angle considering pad elasticity effect.

지지력에 미치는 재하속도에 관한 해석적 연구 (Effect of Loading Rate to Bearing Capacities)

  • 박중배
    • 한국지반공학회지:지반
    • /
    • 제13권1호
    • /
    • pp.147-158
    • /
    • 1997
  • 본연구는 유한요소법을 이용하여 중간토지 반에 있어서의 부분배수의 정도가 지지력 및 변형 특성에 미치는 영향을 해석적으로 고찰한 것이다. 동시에 계산 결과를 모형실험 결과와 비교하여 계산법의 타당성 및 부분배수의 현상이 발생하는 지반의 지지력 문제에의 적용성을 검토하였다. 해석에는 수정 Cam-clay를 이용한 프로그램 CRISP90을 이용하였고,모델실험에서는 원심 모형시험장치를 이용하였다. 해석 결과, 부분배수의 영향을 받는 중간토지반의 하중칙하 관계를 충분한 정도로 표현할 수 있으며, 동법에 의해 상대재하속도를 배수, 비배수 및 부분배수영역의 3영역으로 분류 가능하고, 부분배수 영역의 범위는 10절도임을 밝혔다.

  • PDF

간척지 온실기초 보강을 위한 심층혼합처리공법의 허용지내력 및 침하량 산정 (Estimation of Allowable Bearing Capacity and Settlement of Deep Cement Mixing Method for Reinforcing the Greenhouse Foundation on Reclaimed Land)

  • 이학성;강방훈;이광승;이수환
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.287-294
    • /
    • 2021
  • 국가관리 간척지내 원예단지 조성에 필요한 기반기술 중에 하나인, 온실기초 연구가 부족한 실정이며 고사양의 PHC파일을 대체하기 위한 대안을 검토하고자 하였다. 지반개량공법 중 심층혼합처리공법(DCM) 적용시 허용지지력과 침하량 산정을 통하여 온실기초 공법으로써의 적용가능성을 검토하였다. 새만금간척지 농생명용지 1공구 지반조사를 통해 지반 특성을 파악하고, Terzaghi, Meyerhof, Hansen, Schmertmann 이론식을 적용하여 허용지지력과 침하량을 산정하였다. 직경 800mm를 기준으로, 독립 기초 폭과 길이가 3-6m이고, 기초 심도 3-7m 조건에서 허용지지력과 침하량을 검토하였다. 온실기초 심도가 얕고 콘크리트 매트 간격이 넓을수록 시공비가 절감되는 측면을 고려하여 독립 기초 폭과 길이가 4m, 기초 심도가 3m인 경우가 가장 적합한 것으로 판단되었다. 독립 기초 폭과 길이가 4m이고, 기초 심도가 3m인 조건에 대한 해석 결과로 허용지지력은 169kN/m2, 침하량은 2.73mm로 지지력은 이론식 대비 5.6%의 오차를, 침하량은 62.3%의 오차범위를 나타냈다. 향후, 위 검증된 설계 값을 기준으로 구조 시험과 침하모니터링을 통해 신뢰성을 검증하고자 한다. 그 외 나무말뚝, 헬리컬기초 등 유리온실, 내재해형온실에 적용 가능한 기초 공법과의 비교 검증을 통해 각각의 장, 단점을 파악하고 PHC 파일의 대체 가능 유무를 검토할 예정이다. 이는 온실 유형별 시공 공법을 선정하는데 필요한 기초 데이터로 제시될 수 있을 것으로 기대된다.