• 제목/요약/키워드: beam-girder system

검색결과 94건 처리시간 0.024초

S자형 들보에 의해 지지되는 micromirror의 제작 및 동작특성 분석 (A Study on the Fabrication and Characterization of Micromirrors Supported by S-shape Girders)

  • 김종국;김호성;신형재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.748-754
    • /
    • 1999
  • Micromirrors supported by S-shape girders were fabricated and their angular deflections were measured using a laser-based system. A micromirror consists of a $50\mum\times50\mum$ aluminum plate, posts and an S-shape girder. Two electrodes were deposited on two corners of the substrate beneath the mirror plate. $50\times50$micromirror array were fabricated using the Al-MEMS process. The electrostatic force caused by the voltage difference between the mirror plate and one of the electrodes causes the mirror plate to tilt until the girder touches the substrate. Bial voltage of the mirror plate is between 25~35V and signal pulse voltage on both electrodes is $\pm5V$. A laser-based system capable of real-time two-dimensional angular deflection measurement of the micromirror was developed. The operation of the system is based on measuring the displacement of a HeNe laser beam reflecting off the micromirror. The resonant frequency of the micromirror is 50kHz when the girder touches the substrate and it is 25 when the micromirror goes back to flat position, since the moving mass is about twice of the former case. The measurement results also revealed that the micromirror slants to the other direction even after the girder touches the substrate.

  • PDF

Strengthening of prestressed girder-deck system with partially debonding strand by the use of CFRP or steel plates: Analytical investigation

  • Haoran Ni;Riliang Li;Riyad S. Aboutaha
    • Computers and Concrete
    • /
    • 제31권4호
    • /
    • pp.349-358
    • /
    • 2023
  • This paper describes an in-depth analysis on flexural strength of a girder-deck system experiencing a strand debonding damage with various strengthening systems, based on finite element software ABAQUS. A detailed finite element analysis (FEA) model was developed and verified against the relevant experimental data performed by other researchers. The proposed analytical model showed a good agreement with experimental data. Based on the verified FE model, over a hundred girder-deck systems were investigated with the consideration of following variables: 1) debonding level, 2) span-to-depth ratio (L/d), 3) strengthening type, 4) strengthening material thickness. Based on the data above, a new detailed analytical model was developed and proposed for estimating residual flexural strength of the strand-debonding damaged girder-deck system with strengthening systems. It was demonstrated that both finite element model and analysis model could be used to predict flexural behaviors for debonding damaged prestressed girder-deck systems. Since the strands are debonding from surrounding concrete over a certain zone over the length of the beam, the increase of strain in strands can be linked with a ratio ψ, which is Lp/c. The analytical model was proposed and developed regarding the ratio ψ. By conducting procedure of calculating ψ, the ψ value varies from 9.3 to 70.1. Multiple nonlinear regression analysis was performed in Software IBM SPSS Statistics 27.0.1 to derive equation of ψ. ψ equation was curved to be an exponential function, and the independent variable (X) is a linear function in terms of three variables of debonding level (λ), span length (L), and amount of strengthening material (As). The coefficient of determinate (R2) for curve fitting in nonlinear regression analysis is 0.8768. The developed analytical model was compared to the ultimate capacities computed by FEA model.

강합성 2-거더교의 가로보 배치 간격 및 소요 휨강성에 관한 연구 (A Study on the Spacing and Required Flexural Rigidity of Cross Beams in Composite Two-Steel Girder Bridges)

  • 박용명;조현준;황민오
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.1-10
    • /
    • 2004
  • 본 논문에서는 수직 및 수평 브레이싱을 생략하고 I-형 거더를 가로보만으로 연결한 강합성 2-거더교에서 가로보의 적정 배치간격 및 소요 휨강성의 산정을 위한 연구를 수행하였다. 이를 위해 지간 40m의 단순교와 40+50+40m의 2차로 연속교를 예제교량으로 시산 설계하였다. 본 교량에 대해 중간가로보의 배치 간격과 휨강성을 매개변수로 하여 합성전 후 고정하중, 활하중, 풍하중 및 지진하중에 대한 해석을 수행하고 설계하중조합에 대한 응력 및 활하중 분배효과를 분석하였다. 한편, 강재 거더와 가로보의 격자구조에 대해 합성전 고정하중을 고려한 재료-기하 비선형해석으로부터 횡비틀림 좌굴강도를 평가하였다. 이상의 해석 결과를 토대로 지점부 및 중간가로보의 적정 배치 간격과 소요 휨강성을 제안하였다.

T형 교각의 탄성변형을 고려한 슬래브교의 유한요소 해석 (Finite Element Analysis Reinforced Concrete Slab Bridge Considering Elastic deformations of Reinforced Concrete T-type Piers)

  • 이성철;윤동열
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.100-110
    • /
    • 2000
  • In practical design of girder bridges or reinforced concrete slab bridges with T-type piers, it is usually assumed that vertical movements of superstructures are completely restrained at the locations of bearings(shoes) on a cap beam of the pier, The resulting vertical reactions are applied to the bearing for the calculation of bending moments and shear forces in the cap beam. However, in reality, the overhang parts of the cap beam will deform under the dead load of superstructures and the live load so that it may act as an elastic foundation. Due to the settlement of the elastic foundation, the actual distribution of the reactions at the bearings along the cap beam may be different from that obtained under the assumption that the vertical movements are fixed at the bearings. In the present study, investigated is the effects of elastic deformations of the T-type pier on the distribution of reactions at the bearings along the cap beam through 3-dimensional finite element analysis. Herein, for this purpose the whole structural system including the superstructure and piers as well is analyzed. It appears that the conventional practice which neglects the elastic deformations of the cap beam exhibits considerably different distributions of the reactions as compared with those obtained from the present finite element analysis. It is, therefore, recommended that in order to assess the reactions at bearings correctly the whole structural system be analyzed using 3-dimensional finite element analysis.

  • PDF

Vibration analysis of prestressed concrete bridge subjected to moving vehicles

  • Huang, M.;Liu, J.K.;Law, S.S.;Lu, Z.R.
    • Interaction and multiscale mechanics
    • /
    • 제4권4호
    • /
    • pp.273-289
    • /
    • 2011
  • The vibration response of the bridges under the moving vehicular load is of importance for engineers to estimate the serviceability of existing bridges and to design new bridges. This paper deals with the three dimensional vibration analysis of prestressed concrete bridges under moving vehicles. The prestressed bridges are modeled by four-node isoparametric flat shell elements with the transverse shearing deformation taken into account. The usual five degrees-of-freedom (DOFs) per node of the element are appended with a drilling DOF to accommodate the transformation of the local stiffness and mass matrices to the global coordinates. The vehicle is modeled as a single or two-DOF system. A single-span prestressed Tee beam and two-span prestressed box-girder bridge are studied as the two numerical examples. The effects of prestress forces on the natural frequencies and dynamic responses of the bridges are investigated.

고속철도교량의 새로운 3차원 유한요소 해석모델의 개발 (Development of a New Three-dimensional Finite Element Analysis Model of High-speed Railway Bridges)

  • 송명관;한인선;김선훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.444-451
    • /
    • 2003
  • In this study, a new three-dimensional finite element analysis model of high-speed railway bridges considering train-bridge interaction, in which various improved finite elements are used for modeling structural members, is proposed. The box-type bridge deck of a railway bridge is modeled by the NFS(Nonconforming Flat Shell) elements with 6 degrees of freedom. Track structures are idealized using the beam finite elements with the offset of beam nodes and those on Winkler foundation with two parameters. And, the vehicle model devised for a high-speed train is employed, which has an articulated bogie system. By Lagrange's equations of motion, the equations of motion of a bridge-train system can be formulated. Finally, by deriving the equations of the forces acting on a bridge considering bridge-train interaction the complete system matrices of total bridge-train system can be constructed. As numerical examples of this study, 2-span PC box-girder bridge is analyzed and results are compared with experimental results.

  • PDF

친환경 층고 절감형 합성보의 보-기둥 접합부 상세 및 시공성 연구 (Environmental Friendly Connection of Composite Beams and Columns)

  • 홍원기;김진민;박선치;임선재
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.113-118
    • /
    • 2007
  • The composite beam adopted in the study was designed to reduce the floor height as well as to embed the top flange of steel frame into the slab that will enable to avoid applying the fire-resistant coating and to unify the joint method with a steel frame-type. As the steel frame and bottom concrete of the beam is pre-fabricated at the factory it could reduce the overall schedule at the jobsite. Applying such composite beam system to the work is expected to provide the efficient and enhanced performance, given the current tendency of the building construction that tends to be getting higher, larger and dense. The study focused on combining the composite beam with various column systems in a bid to propose the details thereof. A desirable composite girder can be adopted depending on site conditions through the evaluation of various beam and jointing approaches. Among the column systems applied to the study are steel column, SRC column, RC-PC column and RC column. The ways of combining with the columns addressed in the study were categorized into the rigid joint, pin joint, steel frame joint and bracket type joint. Besides, the instruction for site fabrication of beam-column was added in an effort to help set up the site fabrication procedures.

철근콘크리트 기둥과 철골 보의 접합부 형식 발전 및 용접성능에 관한 시험적 연구 (A Study on the Improvement and Test on Welding Performance of R/C Column-Steel Girder Connection)

  • 최광호;이세웅;김재순;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.569-574
    • /
    • 1997
  • This research has improved composite joint system of R/C column and steel beam developed at previous study. In this system, the shear force occurred at beam is transmitted by bearing resistance of stiffness and moment is resisted by tension capacity of coupling members. As the preliminary step of stress transfer tests of this system, welding performance test of coupling member such as round bar or square bar which has a role of moment transfer has been carried out. From the test, this element has a good welding performance and enough resistance capacity compared to design force.

  • PDF

Perfobond Rib을 적용한 강-PSC 혼합구조 연결부의 거동 평가 (Behaviors of Joints with Perfobond Rib Shear Connectors in Steel-PSC Hybrid System)

  • 김상효;이찬구;윤지현;원정훈
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.647-657
    • /
    • 2009
  • 본 연구는 강-프리스트레스 콘크리트(PSC) 혼합구조 보를 분절형 교량에 적용하기 위해 필수적으로 요구되는 이종 부재간의 연결에 대한 기초연구로써, 연결부 거동과 시공성을 향상시키기 위해 연결부 상․하부 플레이트에 perfobond rib 전단연결재를 설치한 강-PSC 연결부를 제안하였다. 제안된 연결부가 설치된 보 실험체들을 제작하여 하중재하실험을 통해 연결부의 성능을 확인한 결과, 모든 실험체에서 연결부의 파괴 없이 연결부 인접 PSC부에서 실험체의 파괴와 극한강도가 나타났다. 합성 작용에 의하여 실험체의 초기 강성은 우수한 것으로 나타났으며, 균열의 진전 형상도 전형적인 휨 균열 형상을 나타내었다. 또한, 기존 스터드를 적용한 실험체 이상의 강도를 얻을 수 있는 것으로 나타났다. 그러므로 제안된 연결부는 혼합구조 연결부에 효과적으로 적용 가능하다고 판단된다.

보강강판을 이용한 연속 PSC 교량 공법에 관한 연구 (A Study of continuous PSC bridge with a reinforcement steel plate)

  • 구민세;김훈희;정영도
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.422-429
    • /
    • 2005
  • It is limited to decrease height or section even by system conversion to indeterminate structure - continuous beam - in existing PSC girder bridges. In this study, the movement of connection is analyzed through actual field test, by increasing stiffness of negative moment area in continuous PSC bridge and developing continuous PSC bridge with embedded steel plate, that can overcome the demerit of existing connection. As a result, it is confirmed that the body unification of the connection is being realized and maintained. Moreover, the height of a span is suggested in continuous PSC girder bridge with embedded steel plate by computational analysis

  • PDF