• Title/Summary/Keyword: beam members

Search Result 716, Processing Time 0.034 seconds

Review of design parameters for FRP-RC members detailed according to ACI 440.1R-06

  • Jnaid, Fares;Aboutaha, Riyad
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.105-121
    • /
    • 2013
  • This paper investigates the parameters that control the design of Fiber Reinforced Polymer (FRP) reinforced concrete flexural members proportioned following the ACI 440.1R-06. It investigates the critical parameters that control the flexural design, such as the deflection limits, crack limits, flexural capacity, concrete compressive strength, beam span and cross section, and bar diameter, at various Mean-Ambient Temperatures (MAT). The results of this research suggest that the deflection and cracking requirements are the two most controlling limits for FRP reinforced concrete flexural members.

Elastic Local Buckling for Orthotropic Channel Section Compression Members with Edge Stiffeners (연단보강된 직교이방성 Channel 단면 압축재의 탄성국부좌굴)

  • 최원창;정상균;윤순종
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.91-94
    • /
    • 2001
  • This paper presents the analytical investigation pertaining to the local buckling behavior of orthotropic channel section compression members stiffened with unsymmetric stiffeners at its free edges. In the analysis, tile edge stiffener is modeled as a beam element or a plate element. The result of both cases is presented in graphical form so that the effects of edge stiffeners on the local buckling strength of edge stiffened channel section member can be found.

  • PDF

Nondestructive Evaluation of Concrete Members using Impact Echo and SASW Methods (충격반향기법과 표면파기법을 이용한 콘크리트 부재의 비파괴 검사)

  • 김동수;박형춘;이광명
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.164-168
    • /
    • 1995
  • As nation's infrastructure is getting old, nondestructive evaluation of existing structures and construction quality control are getting important. In this paper non-destructive evaluations of concrete members using impact echo and SASW methods are introduced. Both techniques are based on the stress wave propagations. Experimental tests were performed using beam type concrete member where voids and cracks are included. Within reasonable accuracy, void locations were detected using impact echo method and the dynamic modulus of concrete were measured using SASW method. Both NDT methods showed a feasibility for the implementation into quality evaluaton of concrete members in practice

  • PDF

Basic study for time analysis of insitu production of composite precast concrete members using linear scheduling method (LSM을 사용한 합성 PC 부재의 현장생산 공기 산정 기초연구)

  • Lim, Chaeyeon;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.92-93
    • /
    • 2014
  • Green Frame is a method for Rahmen structure construction composed of composite PC members. The composite PC members of Green Frame which are based on in-situ production can reduce the construction cost and are more likely to secure quality when compared to production in factories. Previous studies developed forms for in-situ production of Green Frame composite PC members and proposed algorithms to arrange them on site. However, it requires not only their arrangement, but also calculation of an accurate production period to produce the required PC members in a limited space and supply them in a timely manner. In particular, it is necessary to clearly define the properties of detailed processes for in-situ production of PC members and to calculate the time required for respective process. To do so, this study is a basic research on calculating the time for in-situ production using a linear scheduling method.

  • PDF

Test of SRC Column-to-Composite Beam Connection under Gravity Loading (중력하중을 받는 SRC기둥-합성보 접합부 실험)

  • Kim, Young Ju;Bae, Jae Hoon;Ahn, Tae Sang;Jang, Seong Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.441-452
    • /
    • 2014
  • In this paper, steel reinforced concrete(SRC) column and composite beam connections were statically tested under gravity loading. The composite beam consists of H-section and U-section members. Five full-scaled specimens were designed to investigate the effect of a number of parameters on behavior of connections such as H-section size, the presence of stud connector, the presence of stiffeners and top bars. In addition, structural performance of welded joint between the H-section and the U-section members is mainly discussed, with an emphasis on initial stiffness, strength, deformation capacity.

Study on the Bending Test of Glulam Beam Reinforced with GFRP Strips (복합재료로 보강된 집성보의 휨 실험에 대한 연구)

  • Kim, Young-Chan;Davalos, Julio F.
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.199-204
    • /
    • 1999
  • A recent application of advanced composite materials, primarily fiber-reinforced plastic (FRP) composites, in structures is the reinforcement of conventional structural materials, such as concrete and glued-laminated timber (glulam), to increase their performance. In particular, the construction of large-scale glulam structures usually requires members with large depths and to significantly increase the stiffness and strength of glulam, the members can be reinforced with FRP at top and bottom surfaces. In this paper, glulam beams reinforced with GFRP strip are tested under 2-point bending and results are compared with numerical solution using layer-wise beam theory.

  • PDF

Beam-Column Element Applicable to Nonlinear Seismic Analysis (비선형 지진 해석을 위한 보-기둥 요소)

  • Kim, Kee Dong;Ko, Man Gi;Lee, Sang Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.557-578
    • /
    • 1997
  • The objective of the study in this paper was to develop a beam-column element to model members with purely flexural yielding, as well as members with yielding under combined flexure and axial force during severe earthquake ground motins. The developed element can be considered as an one-component series hinge type model. It has the capability to model plastic axial deformation and changes in axial stiffness, and employs hardening rules to handle monotonic, cyclic or arbitrary loading. In general, when compared to experimental results and fiber model predictions, the element showed significantly better performance than the bilinear hinger model and could properly model the beam-column behavior of bare steel members in moment resisting frames. The developed element can more accurately predict local deformation demands and overall responses of structural systems under earthquake loadings than the bilinear hinge element.

  • PDF

Microscale BTS sculptured by electron beam

  • Choi, Haneul;Jeong, Young Woo;Chang, Hye Jung
    • Applied Microscopy
    • /
    • v.49
    • /
    • pp.4.1-4.2
    • /
    • 2019
  • We applied the advanced bitmap-assisted patterning function of focused ion beam to fabricate microscale sculpture of the 'BangTanSoNyeonDan' known as BTS members, the world-wide famous K-pop boyband. With the help of an electron microscope, you can carve your idols on your accessories at micro scale. Fun applications of electron microscopes are not limited to science.

Estimation of production length of PC beam by using splice length of bottom rebar (하부철근 이음길이에 따른 PC 보 제작 길이 산정)

  • Sung, Soojin;Lim, Chaeyeon;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.84-85
    • /
    • 2014
  • Green frame is column-beam structure composed of precast concrete members. Based on Revision of Structural Concrete Design Code, the bottom rebar of beam shall be extend at least 150mm into the support member. However, if the bottom rebar extend to satisfy Revision of Structural Concrete Design Code, the installation fo beam is impossible due to interference between the columns and beams. Thus, the aim of this study is estimation of production length of precast concrete beam by using splice length of bottom rebar. In this study to solve this problem, lap splice were used on the join. This study was calculated length of the reinforcement by the diameter. According to the length of the rebar, the production length of beam concrete was calculated. The results of this study will satisfy the Revision of Structural Concrete Design Code about column-beam connection when green frame will be applied.

  • PDF

Design Aids for a Reinforced Concrete Beam with the Minimum Cost Concept

  • Park, Dalsoo;Ahn, Jeehyun;Lee, Chadon
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.55-61
    • /
    • 1999
  • In reinforced concrete design, structural member sizes and amount of reinforcing steel areas are usually selected based on the structural designers' experience. Most existing charts provided for the design of reinforced concrete structural members were developed mainly based on force equilibrium conditions and some serviceability criteria. Sections selected from these charts may not result in an economic solution in terms of material costs as well as construction costs. Practical design aids are developed and suggested in this study for the economical design of reinforced concrete beam under flexural loading. With the beam width fixed, the depth of a beam, positive steel areas and negative steel areas are found from Khun-Tucker necessary conditions with Lagrangian multipliers to minimize the sectional cost of a beam. The developed design aids might be useful in selecting optimum reinforced concrete beam sections. Theoretical derivations and use of the developed design aids are described in this paper.

  • PDF