Effects of Sujeom-san Water Extract in Cultured Rat Myocardial Cells (수념산 전탕액이 배양 심근세포에 미치는 영향)

  • Jean Young Seok;Kwon Kang Beam;Park Eun Young;Soong Eun Kyung;Park Seung Taeck;Ryu Do Gon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.353-358
    • /
    • 2002
  • To test the protective effect of herbal medicine against oxygen free radical-induced myocardiotoxicity, cytotoxicity of xanthine oxidase/hypoxanthine (XO/HX) was examined using MTT, TBARS, and beating rate assay in the presence of water extract of Sujeom-san(SJS) or single consituents of its prescription. Myocardial toxicity was evaluated in neonatal rat myocardiocytes in cultures. In the present paper, XO/HX resulted in a decrease in viability and beating rate and increases in lipid peroxidation in cultured myocardial cells. In the effect of SJS water extract, it showed effects from the cardiocytotoxicity induced by XO/HX treatment such as increases in beating rate and decreases in lipid peroxidation. In the effect of Rhizoma Corydalis (RC), Faeces Trogopterori (FT), Fructus Amomi Tsaoko (FAT) and Myrrha on the cardiocytotoxicity, they were significantly effective in blocking the XO/HX-induced cardiocytotoxicity by increase of beating rate in FAT and FT group as well as decrease of lipid peroxidation in FT and RC group. These results show that oxygen free radical elicits toxic effects in cultured myocardial cells derived from neonatal rat, and suggest that water extract of Sujeomsan, Rhizoma Corydalis, Faeces Trogopterori, Fructus Amomi Tsaoko or Myrrha is very effective in the prevention of xanthine oxidase/hypoxanthine- induced cardiotoxicity.

The Study on the Design and Manufacturing of Large Aperture Cassegrain antenna (대구경 카세그레인 안테나의 설계 및 제작 고찰)

  • 박정기;이돈신
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.2
    • /
    • pp.14-22
    • /
    • 1982
  • The design and manufacfure technology of the large aperture cassegrain antenna was first studied in the country, and its performances in a trial manufactured product are measured and compared. In order to design this cassegrain antenna with reference to several literatures, the schemed order was decided. Especially, for the cassegrain antenna of 4.6m diameter which is becoming the television receiving antenna directly from satellite, in advanced countries, the 1/12 sized small section of its parabolic curved surface is made primarily with the precision of less difference than 1/16λ depth. Cares are taken also on the computer program so that the size and position of primary radiator may satisfy the minimum blocking with the given sub-reflector. The preformances of the designed antenna are shown as being 43dB in gain, 1.15 or less in VSWR, 1.1$^{\circ}$ of beam angle etc., and found to be not worse than those of foreign productions with similar type and size.

  • PDF

Performance Enhancement of Call Admission Control in an Adaptive Array Antenna System (적응형 어레이 안테나 시스템에서의 호 수락제어 알고리즘 성능 개선에 관한 연구)

  • Kim, Min-Jung;Kim, Nak-Myeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.1013-1021
    • /
    • 2004
  • In the WCDMA mobile multimedia communication system, the adaptive array antenna IS adopted to improve the performance of the system by reducing inter-user interference using antenna beam control. Usually, the interference resulted from the higher data rate users is much more significant to the lower data rate users than the other way around, so the overall performance can be enhanced by reducing the interference from higher data rate users. In order to maximize the efficiency of adaptive antenna operation, an optimal call admission control, especially during handoff, adaptive to the data rates is a critical problem. In this paper, We propose a call admission control algorithm based on the Soft QoS concept for the efficient processing of the handoff of higher data rate calls, and an adaptive handoff control mechanism according to the data rates. The proposed algorithm has been evaluated by computer simulation that it accommodates high data rate users among many lower data rate users much better, and the average call blocking probability for lower rate users becomes much lower than the conventional call admission control algorithm.

Performance Analysis of an Adaptive Sector System for Terrestrial Station in Ad-hoc Communication System Between Vessels (선박 간 ad-hoc 통신 시스템에서 육상국용 적응 섹터 시스템의 성능 분석)

  • Lee, Hyung-beom;Kim, Seung-geun;Kim, Jun-ho;Kim, Min-sang;Ko, Hak-lim;Im, Tae-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.2
    • /
    • pp.263-268
    • /
    • 2016
  • A rapid increase of data amount, used in ship-to-ship transmission of safety and logistics information, ships in the inland sea have trouble transmitting real-time information transmission due to an increase in traffic load caused by data transmitted by land station and offshore ships. In this study, therefore, communication is carried out by adaptively controlling the detailed beam width based on the distribution of offshore ships in land station durable in marine environment. Then after the adaptive sector system enabling real-time communication support between ships concentrated in an inland sea and land station is applied, the performance verification is conducted based on the respective Call Blocking Rates of an omnidirectional antenna, fisted sector system, and adaptive sector system. The performance verification result shows that adaptive sector system has better performance than the fixed sector system as the density of ship, q value, increases, and that the smaller the beam width is, the better performance of adaptive sector system will be.

The Effect of Aquaplast on Surface Dose of Photon Beam (Aquaplast가 광자선의 표면선량에 미치는 영향)

  • Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy Materials and Methods: To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in $25{\times}25{\times}3cm^3$ acrylic phantom and set on $25{\times}25{\times}5cm^3$ polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 100cm SSD for $5{\times}5cm^2$, $10{\times}10cm^2$ and $15{\times}15cm^2$ field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types of Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and Khan to correct overresponse of the Markus chamber. Results : The surface doses for open fields of $5{\times}5cm^2$, $10{\times}10cm^2$, and $15{\times}15cm^2$ were $79\%$, $13.6\%$, and $18.7\%$, respectively. The original Aquaplast increased the surface doses upto $38.4\%$, $43.6\%$, and $47.4\%$, respectively. For transformed Aquaplast, they were $31.2\%$, $36.1\%$, and $40.5\%$, respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by $0.2\%$, $1.7\%$, $3.0\%$ without Aquaplast, $0.2\%$, $1.9\%$, $3.7\%$ with transformed Aquaplast, respectively. Conclusion: The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax, however, were not affected by Aquaplast. In conclusion, although the use of Aquaplast in practice may cause some increase of skin and buildup region dose, reductioin of skin-sparing effect will not be so significant clinically.

  • PDF

Exchange Coupling Field and Thermal Stability of Ni80Fe20/[Ir22/Mn78-Mn]/Co75Fe25 Multilayer Depending on Mn Content (Ni80Fe20/[Ir22/Mn78-Mn]/Co75Fe25 다층박막에서 Mn 함유량에 의존하는 교환결합력과 열적안정성)

  • Kim, B.K.;Lee, J.Y.;Kim, S.S.;Hwang, D.G.;Lee, S.S.;Hwang, J.Y.;Kim, M.Y.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.5
    • /
    • pp.187-192
    • /
    • 2003
  • The magnetic and thermal properties of NiFe/[IrMn-Mn]/CoFe with Mn additions have been studied. As-deposited CoFe pinned layers with [IrMn-Mn]layer had dominantly larger exchange biasing field ( $H_{ex}$) and blocking temperature ( $T_{b}$) than those with pure I $r_{22}$M $n_{78}$ used. The $H_{ex}$ and $T_{b}$ improved with 76.8-78.1 vol% Mn, but those of the NiFe/IrMn/CoFe dropped considerably with more addition of 0.6 vol % Mn. The average x-ray diffraction peak ratios of fcc [(111)CoFe, NiFe]/(111)IrM $n_3$ textures for the Mn inserted total vol of 75.5, 77.5, and 79.3% were about 1.4, 0.8, and 0.6, respectively. For the sample without Mn inserted layer, the $H_{ex}$ between IrMn and CoFe layers was almost zero, but it increased to 100 Oe after annealing of 250 $^{\circ}C$. For as-grown two multilayers samples with ultra-thin Mn layers of 77.5 and 78.7 vol %, the $H_{ex}$s were 259 and 150 Oe, respectively. In case of IrMn with 77.5 vol% Mn, the $H_{ex}$ was increased up to 475 Oe at 350 $^{\circ}C$ but decreased to 200 Oe at 450 $^{\circ}C$, respectively. The magnetic properties and thermal stabilities of NiFe/[IrMn-Mn]/CoFe multilayer were enhanced with Mn additions. In applications where higher $H_{ex}$ and $T_{b}$ are required, proper contents of Mn can be used. be used. used.

Spatially-resolved Photoluminescence Studies on Intermixing Effect of InGaAs Quantum Dot Structures Formed by AlAs Wet Oxidation and Thermal Annealing (AlAs 습식산화와 열처리로 인한 InGaAs 양자점 레이저 구조의 Intermixing효과에 관한 공간 분해 광학적 특성)

  • Hwang J.S.;Kwon B.J.;Kwack H.S.;Choi J.W.;Choi Y.H.;Cho N.K.;Cheon H.S.;Cho W.C.;Song J.D.;Choi W.J.;Lee J.I.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Optical characteristics of InGaAs quantum dot (QD) laser structures with an Al native oxide (AlOx) layer as a current-blocking layer were studied by means of photoluminescence (PL), PL excitation, and spatially-resolved micro-PL techniques. The InGaAs QD samples were first grown by molecular-beam epitaxy (MBE), and then prepared by wet oxidation and thermal annealing techniques. For the InGaAs QD structures treated by the wet oxidation and thermal annealing processes, a broad PL emission due to the intermixing effect of the AlOx layer was observed at PL emission energy higher than that of the non-intermixed region. We observed a dominant InGaAs QD emission at about 1.1 eV in the non-oxide AlAs region, while InGaAs QD-related emissions at about 1.16 eV and $1.18{\sim}1.20eV$ were observed for the AlOx and the SiNx regions, respectively. We conclude that the intermixing effect of the InGaAs QD region under an AlOx layer is stronger than that of the InGaAs QD region under a non-oxided AlAs layer.

Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.