• Title/Summary/Keyword: beam blocking

Search Result 48, Processing Time 0.026 seconds

Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator (Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성)

  • Kim, Ok-Bae;Choi, Tae-Jin;Kim, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.115-124
    • /
    • 1990
  • The characteristics of 23 MV photon beam have been presented with respect to clinical parameters of central axis depth dose, tissue-maxi mum ratios, scatter-maximum ratios, surface dose and scatter correction factors. The nominal accelerating potential was found to be $18.5\pm0.5$ MV on the central axis. The half-value layer (HVL) of this photon beam was measured with narrow beam geometry from central axis, and it has been showed the thickness of $24.5\;g/cm^2$. The tissue-maximum ratio values have been determined from measured percentage depth dose data. In our experimental dosimetry, the surface dose of maximum showed only $9.6\%$ of maximum dose at $10\times10\;cm^2$, 100 cm SSD, without blocking tray in. The TMR'S of $0\times0$ field size have been determined to get average $2.3\%$ uncertainties from three different methodis; are zero effective attenuation coefficient, non-ilnear least square fit of TMR's data and effective linear attenuation coefficient from the HVL of 23 MV photon beams of dual energy linear accelerator.

  • PDF

Polymer Eyeglass Lens with Ultraviolet & High-Energy Visible Light Blocking Function for Eye Health (자외선 및 고에너지 가시광 차단 기능을 갖는 눈 건강을 위한 폴리머 안경렌즈)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.10-15
    • /
    • 2020
  • Ultraviolet rays, which have wavelengths smaller than 400 nm, are very harmful to the eyes. Recently, high-energy visible light was also revealed to be harmful to retinal cells. Therefore, polymer eyeglass lenses that can block UV and high-energy visible light are needed for eye health. In this study, high-refractive-index polymer eyeglass lens, n=1.67, were manufactured using the injection-mold method with the m-xylene diisocyanate monomer, 2,3-bis((2-mercaptoethyl)thio)-1-propanethiol monomer, benzotriazole UV absorber, release of alkyl phosphoric ester, dye mixture of CI solvent violet 13, and catalyst of dibutyltin dichloride mixture. A multi-layer anti-reflection coating was applied to manufactured polymer eyeglass lenses for both sides using an E-beam evaporation system. The optical properties of the manufactured lenses with the UV and high-energy visible light-blocking function were analyzed by UV-visible spectrophotometry. As a result, the polymer eyeglass lens with a UV absorber of 0.5 wt. % blocked 99% of UV and high-energy visible light shorter than 411 nm. The average transmittance of the polymer eyeglass lens with a UV absorber of 0.5wt.% was 97.9% in the range of 460 ~ 660 nm for photopic eye sensitivity higher than 10%. Therefore, clear image acquisition in photopic vision is possible.

Evaluation of available height, location, and patency of the ostium for sinus augmentation from an implant treatment planning perspective

  • Vaddi, Anusha;Villagran, Sofia;Muttanahally, Kavya Shankar;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.243-250
    • /
    • 2021
  • Purpose: The objective of this study was to evaluate the amount of height available for a maxillary sinus augmentation procedure without blocking the ostium and jeopardizing the drainage of the ostiomeatal complex using cone-beam computed tomography (CBCT) imaging. Materials and Methods: A total of 200 sinonasal complexes comprising 100 dentate and 100 edentulous scans were retrospectively assessed using CBCT. Invivo 5.0, a CBCT reconstruction program, was used for image evaluation. The coronal section demonstrating the ostiomeatal complex was selected as a reference view to perform measurements of the sinus. The measurements were done by 2 evaluators in separate sessions. Comparative analyses of measurements were performed between dentate and edentulous patients and between male and female patients. Results: The safe height to which the sinus can be elevated without compromising the integrity of the ostiomeatal complex was calculated for each sinus. In the presence of significant mucosal thickening, the height available for augmentation was calculated by subtracting the height of mucosal thickening from the sinus floor to the location of the ostium. In this study, the available height was approximately 27.05 mm for dentate and 23.40 mm for edentulous patients. The inter-operator reliability was excellent for all the parameters evaluated. Conclusion: This retrospective study with a limited number of patients from a single university-based site shows that CBCT is valuable in evaluating the location and patency of the ostium for planning sinus augmentation procedures for dental implant placement.

Analysis of Polarization Properties of Optical Isolator for Fiber Laser

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil;Cho, Kyung-Jae;Kang, Sung-Hak
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.241-244
    • /
    • 2011
  • An isolator transmits light in the forward direction and blocks light from passing in the reverse direction. It is regarded an essential optical component in medical, industrial, and research lasers for blocking reflection beams that cause optical damage and noise. It is also used as a communicative light intensifier to expand the lifespan of devices and enhance transmission quality. This study analyzed the characteristics of the core components in the construction of a polarization-independent isolator, namely, the walk-off polarizer and the Faraday rotator. Measurement of the extinction ratio of the resultant walk-off polarizer revealed that the ratio between the vertical and horizontal rays was 1,050:1 with a laser output of 0.032 W and 1,010:1 with a laser output of 2.68 W, thus presenting ratios similar to 1,000:1. In addition, the walk-off polarizer and Faraday rotator constructed in this study were used to compare output changes according to changes in power of input light and to check the penetration ratio. Results from the study presented variations in output value according to changes in power of input light. However, the average penetration ratio remained relatively consistent (~81.4%).

Improvement of Fire Resistance for Timber Framed Walls by Reinforcement of Heavy Timber Frame

  • Park, Joo-Saeng;Hwang, Kweon-Hwan;Kim, Kwang-Mo
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.6
    • /
    • pp.469-478
    • /
    • 2010
  • Fire resistance of new hybrid timber framed wall systems was evaluated in this study. These wall systems are composed of two major structural parts. One part is a heavy timber frame part designed to take charge of whole vertical load using heavy timber post and beam, and the other is an infill wall structure, designed to take charge of whole horizontal load and to provide an established level of fire resistance. A basic concept of this hybrid wall is adopted from a typical furniture structure with frame. A timber post and beam frame is constructed with Japanese Larch solid timber post(180mm by 180mm) and beam(180mm by 240mm). As infill wall systems, two types of walls are applied. One is a typical light timber framed wall with solid blocking and another is a structural insulated panel wall, in which polystyrene insulation is filled between two structural panels to make single structure. For all tested walls, two layers of 12.5mm thick type-X gypsum boards are used on fire exposed side. Prior to tests for hybrid walls, only infill walls are tested without heavy timber frame. All fire resistance tests are carried out in accordance with KS F 2257, and temperatures on several points within wall structure and unexposed wall surface are measured during fire tests. It is considered that the reinforcement of heavy timber frame is significantly efficient for improving the fire resistance of timber framed walls.

  • PDF

Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator (6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구)

  • Lee, Cheol-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Investigation charge trapping properties of an amorphous In-Ga-Zn-O thin-film transistor with high-k dielectrics using atomic layer deposition

  • Kim, Seung-Tae;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.264-264
    • /
    • 2016
  • 최근에 charge trap flash (CTF) 기술은 절연막에 전하를 트랩과 디트랩 시킬 때 인접한 셀 간의 간섭현상을 최소화하여 오동작을 줄일 수 있으며 낸드 플래시 메모리 소자에 적용되고 있다. 낸드 플래시 메모리는 고집적화, 대용량화와 비휘발성 등의 장점으로 인해 핸드폰, USB, MP3와 컴퓨터 등에 이용되고 있다. 기존의 실리콘 기반의 플래시 메모리 소자는 좁은 밴드갭으로 인해 투명하지 않고 고온에서의 공정이 요구되는 문제점이 있다. 따라서, 이러한 문제점을 개선하기 위해 실리콘의 대체 물질로 산화물 반도체 기반의 플래시 메모리 소자들이 연구되고 있다. 산화물 반도체 기반의 플래시 메모리 소자는 넓은 밴드갭으로 인한 투명성을 가지고 있으며 저온에서 공정이 가능하여 투명하고 유연한 기판에 적용이 가능하다. 다양한 산화물 반도체 중에서 비정질 In-Ga-Zn-O (a-IGZO)는 비정질임에도 불구하고 우수한 전기적인 특성과 화학적 안정성을 갖기 때문에 많은 관심을 받고 있다. 플래시 메모리의 고집적화가 요구되면서 절연막에 high-k 물질을 atomic layer deposition (ALD) 방법으로 적용하고 있다. ALD 방법을 이용하면 우수한 계면 흡착력과 균일도를 가지는 박막을 정확한 두께로 형성할 수 있는 장점이 있다. 또한, high-k 물질을 절연막에 적용하면 높은 유전율로 인해 equivalent oxide thickness (EOT)를 줄일 수 있다. 특히, HfOx와 AlOx가 각각 trap layer와 blocking layer로 적용되면 program/erase 동작 속도를 증가시킬 수 있으며 넓은 밴드갭으로 인해 전하손실을 크게 줄일 수 있다. 따라서 본 연구에서는 ALD 방법으로 AlOx와 HfOx를 게이트 절연막으로 적용한 a-IGZO 기반의 thin-film transistor (TFT) 플래시 메모리 소자를 제작하여 메모리 특성을 평가하였다. 제작 방법으로는, p-Si 기판 위에 열성장을 통한 100 nm 두께의 SiO2를 형성한 뒤, 채널 형성을 위해 RF sputter를 이용하여 70 nm 두께의 a-IGZO를 증착하였다. 이후에 소스와 드레인 전극에는 150 nm 두께의 In-Sn-O (ITO)를 RF sputter를 이용하여 증착하였고, ALD 방법을 이용하여 tunnel layer에 AlOx 5 nm, trap layer에 HfOx 20 nm, blocking layer에 AlOx 30 nm를 증착하였다. 최종적으로, 상부 게이트 전극을 형성하기 위해 electron beam evaporator를 이용하여 platinum (Pt) 150 nm를 증착하였고, 계면 결함을 최소화하기 위해 퍼니스에서 질소 가스 분위기, $400^{\circ}C$, 30 분의 조건으로 열처리를 했다. 측정 결과, 103 번의 program/erase를 반복한 endurance와 104 초 동안의 retention 측정으로부터 큰 열화 없이 메모리 특성이 유지되는 것을 확인하였다. 결과적으로, high-k 물질과 산화물 반도체는 고성능과 고집적화가 요구되는 향후 플래시 메모리의 핵심적인 물질이 될 것으로 기대된다.

  • PDF

UV-nanoimprint Patterning Without Residual Layers Using UV-blocking Metal Layer (UV 차단 금속막을 이용한 잔류층이 없는 UV 나노 임프린트 패턴 형성)

  • Moon Kanghun;Shin Subum;Park In-Sung;Lee Heon;Cha Han Sun;Ahn Jinho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.275-280
    • /
    • 2005
  • We propose a new approach to greatly simplify the fabrication of conventional nanoimprint lithography (NIL) by combined nanoimprint and photolithography (CNP). We introduce a hybrid mask mold (HMM) made from UV transparent material with a UV-blocking Cr metal layer placed on top of the mold protrusions. We used a negative tone photo resist (PR) with higher selectivity to substrate the CNP process instead of the UV curable monomer and thermal plastic polymer that has been commonly used in NIL. Self-assembled monolayer (SAM) on HMM plays a reliable role for pattern transfer when the HMM is separated from the transfer layer. Hydrophilic $SiO_2$ thin film was deposited on all parts of the HMM, which improved the formation of SAM. This $SiO_2$ film made a sub-10nm formation without any pattern damage. In the CNP technique with HMM, the 'residual layer' of the PR was chemically removed by the conventional developing process. Thus, it was possible to simplify the process by eliminating the dry etching process, which was essential in the conventional NIL method.

  • PDF

Effects of Guaruhaebaekbanha-tang Extract on Beating Rate and LDH Activity in Cultured Rat Myocardial Cells (과루해백반하탕 추출물이 배양 심근세포의 박동수와 LDH 활성도에 미치는 영향)

  • An Hyo Chang;Kwon Kang Beam;Park Eun Young;Jang Seung Ho;Ryu Do Gon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.289-295
    • /
    • 2002
  • To certify the protective effect of herbal medicine against oxygen free radical-induced myocardiotoxicity, cytotoxicity was measured using MTT, LDH activity and Beating rate assay in the presence of Guaruhaebaekbanha-tang(GHBT) extracts or single constituents of this prescription. Myocardial toxicity was evaluated in neonatal rat myocardiocytes in cultures. In the present study, xanthine oxidase/hypoxanthine(XO/HX) resulted in a decrease in cell viability, increases in LDH activity in culture medium and decreases in beating rate in cultured myocardial cells. In the effect of GHBT extract, it showed the prevention from the XO/HX-induced cardiotoxicity by the increases of cell viability and beating rate as well as the decrease of LDH activity. In the protective effect of Fructus Trichosanthis(FT), Bulbus Allii Macrostemi(BAM) and Rhizoma Pinelliae(RP), all the extracts were significantly effective in the protection of XO/HX-induced cardiotoxocity in cultured myocardial cells by the increase of beating rate as well as th decrease of LDH activity. From these results, they show that XO/HX is cardiotoxic in cultured myocardial cells derived from neonatal rat, and it suggests that GHBT, FT, SAM, RP extracts are positively effective in the blocking in XO/HX-induced cardiotoxicity.