• Title/Summary/Keyword: beam and diffuse radiation

Search Result 23, Processing Time 0.025 seconds

Thermal performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 내부형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.595-598
    • /
    • 2005
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam radiation) on thermal performance of the collector are studied. However the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector. These effects are considered in this study experimentally and numerically the accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Transient Radiative Heat Transfer Using Finite Volume Method with 2-Order Upwind Scheme and QUICK Scheme (비정상상태 복사열전달 해석을 위한 2 차 상류스킴 및 QUICK 스킴의 유한체적복사해법 적용 연구)

  • Byun, Do-Young;Lee, Gun-Ho;Kim, Man-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1294-1299
    • /
    • 2004
  • Transient radiative heat transfer is analyzed in a one-dimensional slab using finite volume method (FVM). In this study, the step, $2^{nd}$ order upwind, and QUICK schemes are used for incident diffuse radiation and collimated beam, respectively. The results for diffuse radiation show that all schemes applied in this study give good agreements with available published results. In case of collimated beam, however, the results show deviations from the analytical solutions. To successfully describe the propagations of collimated beam, shock capturing schemes such as TVD scheme are need to be developed.

  • PDF

1- Dimensional Transient Radiative Heat Transfer Using Finite Volume Method with 2-Order Upwind Scheme and QUICK Scheme (1차원 비정상상해 복사열전달 해석을 위한 2차 상류스킴 및 QUICK 스킴의 유한체적복사해법 적용 연구)

  • Lee Gun-Ho;Kim Man-Young;Byun Do-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.201-207
    • /
    • 2006
  • Transient radiative heat transfer is analyzed in a one-dimensional slab using finite volume method (FVM). In this study, the step, $2^{nd}$ order upwind, and QUICK schemes are used for incident diffuse radiation and collimated beam, respectively. The results fer diffuse radiation show that all schemes applied in this study give good agreements with available published results. In case of collimated beam however, the results show deviations from the analytical solutions. To successfully describe the propagations of collimated beam shock capturing schemes such as TVD scheme are need to be developed.

Analysis of Solar Radiation Components for the Installation of Solar Thermal System in Korea (국내 태양열시스템 설치를 위한 성분일사량 분석)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.12-18
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since January, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The theoretical analysis of solar radiation as a component has compared with the experimental data obtained by the KIER station. The Result of simulation analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,457cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

Diffuse Pigmented Villonodular Synovitis of the Knee: Case Report (무릎 관절의 미만형 색소 융모 활액막염: 증례 보고)

  • Choi, Sang-Gyu
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.278-282
    • /
    • 2007
  • Purpose: Diffuse pigmented villonodular synovitis (PVNS) is an uncommon aggressive synovial proliferative disorder of unknown etiology affecting the joint linings. Though a histologically benign inflammatory process, because of its aggressive growth with bone destruction or recurrence, it is frequently suggested to occur as a low malignant neoplasm. Optimal treatment is surgery, but the local recurrence rate after radical synovectomy for diffuse PVNS is relatively high due to the infiltrative growth pattern. External beam radiotherapy with moderate doses or intra-articular instillation of radioactive isotopes may improve the likelihood of local control and long-term function in patients with incompletely resected or recurrent diffuse PVNS. I report one case of diffuse PVNS of the right knee joint treated with arthroscopic synovectomy and external beam radiotherapy is presented.

Analysis of Solar Radiation Components in Korea (국내 일사량의 성분 분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.8-12
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since August, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The Result of analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,458cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

  • PDF

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

Relationship between Hourly Clearness Index and Diffuse Ratio at Cheongju Area(II) (청주지방(淸州地方)의 시청명지수(時淸明指數)와 산란비(散亂比)와의 관계(關係)(II))

  • Lee, H.J.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.2
    • /
    • pp.46-50
    • /
    • 1988
  • The estimation of beam radiation intensity on a tilted surface is very important to the design of a solar energy system. In order to get the beam radiation intensity, it is required to calculate the ratio of the diffuse solar radiation to the global radiation ($k_d$). The data measured at Chung-Buk National University. Cheong-ju, (from May 16, 1985 to Nov, 10, 1987) were analysed to define the relationship between hourly clearness index ($k_t$) and diffuse ratio ($t_d$). The results are is follow: 1. The percent of clearness index($k_t$) of less than 0.3 and of more than 0.8 were 2.7% and 3.1% respectively, and between 0.5 and 0.8 was 76.5%. 2. The regression equation between $k_t$ and $k_d$ was an exponential function as: $$k_d=\[{1\hspace{120}:\hspace{10}(k_t<0.1)\\1.28{\times}0.074^{k_t}\hspace{30}:\hspace{10}(0.1{\leq}=k_t<0.9)\\0.12\hspace{98}:\hspace{10}(0.9{\leq}=k_t)$$ There was a little difference between the result. of this study based on the data of 30 months and the results of previous study (ITRA 2(1):42-47, 1986.) based on the data of 8 months. 3. The hourly exponential regression equation between $k_t$ and $k_d$ was $k_d=A{\times}8^{k_t}$ and the values of constant A and coefficient B of the: equations are as the following table; 4. The percent of $k_d$ of less than 0.4 was 72.9% and of more than 0.7 was 6.6%. 5. Total mean value of $k_t$ and $k_d$ wert 0.56 and 0.32, respectively. From 10:00 to 15:00 o'clock the total mean value of $k_t$ was smaller that the hourly man value of $k_t$ and the one or $k_d$ larger.

  • PDF

A Study on the Analysis of Solar Radiation Characteristics on a High Elevated Area (고지대 일사량 특성분석에 관한 연구)

  • Jo, Dok-Ki;Kang, Young-Heack;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • The purpose of this study is to procure basic data to be used for solar power plant and concentrating collector designs. Site elevation is one of the major factors which influences the incoming insolation to the earth surface. Because the nonpermanent gases such as ozone, water vapor are unmixed components of the atmosphere and their concentrations are the function of height, the site elevation effects the relative proportion of the atmospheric constituents. We have measured solar radiation on Jiri Mt. (1,400m) and in Gurye area(115m) at the near same latitude. These values were then compared to obtain their characteristics and to investigate the potential for the solar utilization for both high and low elevated areas. From the experimental results, we concluded that 1) Daily mean horizontal global radiation and normal beam radiation on Mt. Jiri are 9.5%, and 35.3% higher than Gurye area respectively for a clear day. 2) A significant difference in atmospheric clearness index is observed between Mt. Jiri and Gurye areas.

A Study on the Optimal Installation of Solar Photovoltaic System in Korea (국내 태양광발전시스템의 최적 설치에 관한 연구)

  • Jo, Dok-Ki;Kang, Yong-Heack;Lee, Euy-Joon;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • The measured solar radiation incident on tilted surfaces by all directions has been widely used as important solar radiation data in installing photovoltaic modules. To maximize the incident beam radiation, the slope, which is the angle between the plane of the surface in question and the horizontal, an4 the solar azimuth angles are needed for these solar photovoltaic systems. This is because the performance of the solar photovoltaic systems is much affected by angle and direction of incident rays. Recognizing those factors mentioned above are of importance, actual experiment has been performed in this research to obtain the an91e of inclination with which the maximum incident rays can be absorbed. The results obtained in this research could be used in installing optimal photovoltaic modules.