• Title/Summary/Keyword: beagle

Search Result 427, Processing Time 0.028 seconds

Prediction of apparent total tract digestion of crude protein in adult dogs

  • Kangmin Seo;Hyun-Woo Cho;Min Young Lee;Chan Ho Kim;Ki Hyun Kim;Ju Lan Chun
    • Journal of Animal Science and Technology
    • /
    • v.66 no.2
    • /
    • pp.374-386
    • /
    • 2024
  • To predict the apparent total tract digestibility (ATTD) of crude protein (CP) in dogs we developed an in vitro system using an in vitro digestion method and a statistical analysis. The experimental diets used chicken meat powder as the protein source, with CP levels of 20% (22.01%, analyzed CP value as dry-based), 30% (31.35%, analyzed CP value as dry-based), and 40% (41.34%, analyzed CP value as dry-based). To simulate in vivo digestive processes a static in vitro digestion was performed in two steps; stomach and small intestine. To analyze ATTD the total fecal samples were collected in eight neutered beagle dogs during the experimental period. CP digestibility was calculated by measuring CP levels in dog food, in vitro undigested fraction, and dog feces. In result, CP digestibility at both in vivo and in vitro was increased with increasing dietary CP levels. To estimate in vivo digestibility the co-relation of in vivo ATTD and in vitro digestibility was investigated statistically and a regression equation was developed to predict the CP ATTD (% = 2.5405 × in vitro CP digestibility (%) + + 151.8). The regression equation was evaluated its feasibility by using a commercial diet. The predicted CP digestibility which was calculated by the regression equation showed high index of similarity (100.16%) with that of in vivo in dogs. With that, it would be a feasible non-animal method to predict in vivo CP digestibility by using in vitro digestion method and the proposed linear regression equation in adult dogs.

The Analysis of Quantitative EEG to the Left Cranial Cervical Ganglion Block in Beagle Dogs (비글견에서 좌측앞쪽목신경절 차단에 대한 정량적 뇌파 분석)

  • Park, Woo-Dae;Bae, Chun-Sik;Kim, Se-Eun;Lee, Soo-Han;Lee, Jung-Sun;Chang, Wha-Seok;Chung, Dai-Jung;Lee, Jae-Hoon;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.514-521
    • /
    • 2007
  • The sympathetic nerve block improves the blood flow in the innervated regions. For this region, the sympathetic nerve block has been performed in the neural and cerebral disorders. However, the cerebral blood flow regulation of the cranial cervical ganglion block in dogs have not been well defined and the correlation to the changes in the cerebral circulation and the changes in the electroencephalogram is not well defined in dogs yet. Therefore, we investigated the hypothesis that changes in the EEG could be affected by the changes in cerebral blood flow following the cranial cervical ganglion block in dogs. Twenty five beagle dogs were divided into 3 groups; group I(LCCGB, n=10) underwent left sided cranial cervical ganglion block using the 1% lidocaine, group II(L, n=10) injected the 1% lidocaine into the right or left sided digastricus muscle, group III(N/SCCGB, n=5, served as control) underwent the left sided cranial cervical ganglion block using saline. A statistical difference was not found between the control group and the LCCGB group in the 95% spectral edge frequency(SEF) and the median frequency(MF). In the relative band power, the $\delta$ frequency was decreased during 5-25 min, while the $\alpha$ frequency was increased during the same time(p<0.05). But the $\theta$ frequency and the $\beta$ frequency were not shown the significant changes compared with the control group during the same time(p<0.05). These results suggest that the left cranial cervical ganglion block does not induce the change of the cerebral blood flow and its effect is insignificant.

Quantitative Expression Analysis of Functional Genes in Four Dog Breeds (개의 네 품종에서 기능 유전자들에 대한 정량적 발현 분석)

  • Gim, Jeong-An;Kim, Sang-Hoon;Lee, Hee-Eun;Jeong, Hoim;Nam, Gyu-Hwi;Kim, Min Kyu;Huh, Jae-Won;Choi, Bong-Hwan;Kim, Heui-Soo
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.861-869
    • /
    • 2015
  • One of the domesticated species; the dog has been selectively bred for various aims by human. The dog has many breeds, which are artificially selected for specific behaviors and morphologies. Dogs contribute their life to human as working dogs for guide, rescue, detection or etc. Working dogs requires good personality, such as gentleness, robustness and patience for performing their special duty. Many studies have concentrated on finding genetic marker for selecting the high-quality working dog. In this study, we confirmed quantitative expression patterns of eight genes (ABAT; 4-Aminobutyrate Aminotransferase, PLCB1; Phospholipase C, Beta 1, SLC10A4; Solute Carrier Family 10, Member 4, WNT1; Wingless-Type MMTV Integration Site Family, Member 1, BARX2; BarH-Like Homeobox 2, NEUROD6; Neuronal Differentiation 6, SEPT9; Septin 9 and TBR1; T-Box, Brain, 1) among brains tissues from four dog breeds (Beagle, Sapsaree, Shepherd and Jindo), because these genes were expressed and have functions in brain mostly. Specially, BARX2, SEPT9, SLC10A4, TBR1 and WNT1 genes were highly expressed in Beagle and Jindo, and Sapsaree and German Shepherd were vice versa. The biological significance of total genes was estimated by database for annotation, visualization and integrated discovery (DAVID) to determine a different gene ontology (GO) class. In these analyses, we suppose to these eight genes could provide influential information for brain development, and intelligence of organisms. Taken together, these results could provide clues to discover biomarker related to functional traits in brain, and beneficial for selecting superior working dogs.

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

The effects of polylactic/polyglycolic copolymer (PLA/PGA) membrane on the healing of 1-wall intrabony defects in beagle dogs (성견 1면 골 결손부에서 Polylactic/polyglycolic acid copolymer (PLA/PGA) 흡수성 차단막의 치주 조직 재생에 대한 연구)

  • Kim, Sung-Koo;Hwang, Sung-Joon;Kim, Min-Kyoung;Kim, Chang-Sung;Lee, Doug-Youn;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.599-613
    • /
    • 2003
  • The goal of periodontal treatment is regeneration of the periodontium. Bone graft and absorbable PLA/PGA membrane have been used for this purpose. In this study, 4${\times}$4mm 1-wall intrabony defects were surgically created bilaterally in the mandible of five male beagles. The control group went through a conventional flap operation, while the experimental group I was treated with absorbable PLA/PGA membranes only, group II was treated with absorbable membrane and calcium phosphate. The results are the following : 1. The defect height was 4.82${\pm}$0.45mm in the control group, 4.93${\pm}$0.79mm in the experimental I group, and 4.92${\pm}$0.62mm in the experimental II group. There was no statistically significant difference among 3 groups(P <0.05). 2. The amount of junctional epithelium migration was 30.90${\pm}$9.92% of the defect height in the control group, 39.16${\pm}$7.51% in the experimental I group, and 38.68${\pm}$12.22% in the experimental II group. There was no statistically significant difference among 3 groups(P <0.05). 3. The amount of connective tissue adhesion was 36.38${\pm}$9.03% in the control group, 14.73${\pm}$3.93% in experimental I group, and 27.87${\pm}$9.70% experimental II group. Experimental group I was a statistically significantly different from control group(P <0.05). 4. The amount of new cementum regeneration was 32.92${\pm}$10.51%, 50.04${\pm}$7.61%, and 39.62${\pm}$12.14% for the control, experimental I, and experimental II group respectively. Experimental group I was a statistically significantly different from control group(P<0.05). 5. The amount of new alveolar bone regeneration was 27.24${\pm}$7.49%, 40.75${\pm}$8.03%, and 36.47${\pm}$15.11% for the control, experimental I, and experimental II group respectively. Experimental group I was a statistically significantly different from control group(P <0.05). The results suggest that the use of PLA/PGA membrane in 1-wall intrabony defect of beagle dogs may promote periodontal regeneration. Further studies are required to determine their regeneration effects.

Effects of implant collar design on marginal bone and soft tissue (임플란트의 collar design이 변연골과 연조직에 미치는 영향)

  • Yoo, Hyun-Sang;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effects of implant collar design on marginal bone change and soft tissue response by an animal test. Materials and methods: Two types of Implant (Neobiotech Co. Seoul, Korea) that only differs in collar design were planted on two healthy Beagle dogs. The implants were divided into two groups, the first group with a beveled collar (Bevel Group) and the second group with "S" shaped collar (Bioseal group). Standardized intraoral radiographs were used to investigate the mesio-distal change of the marginal bone. Histological analysis was done to evaluate the bucco-lingual marginal bone resorption and the soft tissue response adjacent to the implant. Mann-Whitney test was done to compare the mesio-distal marginal bone change at equivalent time for taking the radiographs and the tissue measurements between the groups. Results: Radiographic and histological analysis showed that there was no difference in marginal bone change between the two groups (P>.05). Histological analysis showed Bioseal group had more rigid connective tissue attachment than the Bevel group. There was no difference in biological width (P>.05). Bevel group showed significantly longer junctional epithelium attachment and Bioseal group showed longer connective tissue attachment (P<.05). Conclusion: For three months there were no differences in marginal bone change between the Bevel group and the Bioseal group. As for the soft tissue adjacent to the implant, Bioseal group showed longer connective tissue attachment while showing shorter junctional epithelium attachment. There were no differences in biologic width.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

Comparison of Ultrasound Histogram in Liver, Kidney and Spleen in Beagle Dogs (비글견에 있어서 간, 신장 및 비장의 초음파 히스토그램 비교)

  • Lee Kichang;Jung Joohyun;Oh Sunkyoung;Jeong Yucheol;Lim Changyun;Yoon Junghee;Choi Mincheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.186-189
    • /
    • 2005
  • For the assessment of the clinical application of histogram on internal parenchymal organs, ultrasonography with a multi-frequency transducer was taken. We scanned in the region of right cranial abdomen for both liver and right kidney, and left cranial abdomen for liver, spleen and left kidney in 9 normal Beagle dogs. The data from histogram examined in a region of interest centered on each picture element of B-mode images at the same depth were compared among liver, renal cortex, spleen, cortex and medulla of each kidney. The right renal cortex showed significantly lower echogenicity than parenchyma of liver by $15{\%}$. Spleen was more echogenic than the cortex of the left kidney by $23{\%}$, and liver was more echogenic than the left renal cortex by $30{\%}$. Renal cortex was more echogenic than medulla by $47{\%}$ and $65{\%}$ on the right and left side, respectively (p<0.05). The mean (${\pm}SD$) values calculated echogenicity were $46.2{\pm}12.3\;(95\%$ confidential interval (CI), 41.0 to 55.0) and $53.4{\pm}12.1\;(95\%$ CI, 47.0 to 55.1) in in the right renal cortex and liver parenchyma, $65.0{\pm}11.8\;(95\%$ CI, 57.9 to 71.0) and $51.0{\pm}16.9\;(95\%$ CI, 42.8 to 54.1) in splenic parenchyma and renal cortex. And the mean values calculated echogenicity were $65.0{\pm}10.15\;(95\%$ CI, 60.1 to 71.5) and $52.0{\pm}9.4\;(95\$ CI, 43.8 to 60.3) in liver parenchyma and the left renal cortex, $54.5{\pm}18.3\;(95\%$ CI, 40.1 to 62.8) and $35.0{\pm}16.2\;(95\%$ CI, 24.2 to 43.6) in the left renal cortex and medulla. And the mean values calculated echogenicity were $55.0{\pm}14.4\;(95\%$ CI, 47.3 to 61.7) and $40.0{\pm}13.2\;(95\%$ CI, 34.3 to 46.7) in the right renal cortex and medulla, respectively. In addition, the echogenicity ratios were $0.86{\pm}0.11$ between the right renal cortex and liver parenchyma, $1.37{\pm}0.47$ between spleenic parenchyma and the left renal cortex, $1.30{\pm}0.19$ between liver parenchyma and the left renal cortex. All the values measured showed significant different (p<0.05). Ultrasound histogram is simple, useful and feasible to evaluate the sonographic architecture of the internal organs such as liver, spleen and kidney, quantitatively.