• Title/Summary/Keyword: batch tests

Search Result 261, Processing Time 0.022 seconds

Metal-Modified Natural Zeolite for Bacterial Media (미생물 담체 성능 향상을 위한 금속 치환)

  • Kim, Jae-Keun;Min, Jee-Eun;Park, Jae-Woo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.811-813
    • /
    • 2008
  • To see the effect of magnesium on adhesion to natural zeolites, a series of batch tests were performed in this research. Mixed bacteria were sampled from the digestion tank at a local sewage treatment plant in Seoul. Magnesium-zeolites were synthesized by mixing natural zeolites with 0.096 M, 0.24 M, and 0.48 M of MgCl2 solution. For comparison, manganese and trivalent ferric zeolites were also prepared. Two grams of 0.2 mm $\sim$ 0.3 mm sized zeolites(non-treated, Mg, Mn and Fe(III) treated zeolites) and 20 mL of water were mixed in a Corex 25 mL tube. Five milliliters of culture solution including bacteria was added to the tube. The tubes were equilibrated in a shaking incubator at mesophilic temperature $(30{\pm}2^{\circ}C)$. The bacterial concentrations were measured with a Microluminometer (New Horizons 3550i) and total organic carbon (TOC) spectrophotometer (Multi NC-3100).

  • PDF

Evaluation of Phosphorus and Nitrogen Delivery Characteristics of Chogang Stream Sediments (초강천의 퇴적물 분석을 이용한 총인 및 질소의 유달 특성 평가)

  • Kang, Seon-Hong;Seo, Dong-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.99-109
    • /
    • 1997
  • To estimate the nutrients delivery characteristics of Chogang stream to Keum River, sediment and soil characteristics were analyzed in the stream and in the stream bank. Along the stream, soil samples from river sediment were collected and tested monthly for phosphorus and nitrogen concentrations. Nitrogen concentration in the sediment is much lower than that of soil in the river bank especially in summer presumably due to the high desorption characteristics of nitrogen by the increasing rainfall energy during summer. Instead, the concentrations of phosphorus were similar for the sediment and the soil in the river bank due to the strong adsorption characteristics of phosphorus. Batch tests were performed to evaluate the desorption potential of the sediments. Universal Soil Loss Equation (USLE) was applied to quantify soil erosion in each watershed due to rainfall. It was estimated that approximately 25% of total phosphorus by mass basis could be released from the sediment if the water was disturbed vigorously. The mass load of nitrogen and phosphorus into the Chogang Stream from the watershed were evaluated from the USLE and release ratio of phosphorus.

  • PDF

Treatment of Diesel-Contaminated Soils by Fenton Oxidation (디젤로 오염된 토양에의 펜톤 산화공법 적용을 위한 산화제의 주입비 영향 연구)

  • Lim, Myung-Hee;Son, Young-Gyu;Yun, Jun-Ki;Khim, Jee-Hyeong
    • Journal of Environmental Science International
    • /
    • v.17 no.2
    • /
    • pp.203-210
    • /
    • 2008
  • The batch tests were performed to determine the ratio of Fenton reagent on diesel contaminated soil. The objective of a column test was to determine and optimize the hydrogen peroxide requirements for the remediation of a soil contaminated with diesel fuel. The batch test were done on 5 g diesel contaminated soil containing hydrogen peroxide (35%) and Iron (II) sulfate. The $H_2O_2(g):Fe^{2+}(g)$ ratio varied 1:0, 30:1, 15:1, 5:1, 1:1, with contact reaction time 120min. Initial diesel concentration were 2,000 mg/kg, 5,000 mg/kg, and 10,000 mg/kg. Average diesel removal from the contaminated soil is 97% after 2hrs. Results of this study showed possible application of without addition of iron source. In column test, treatment of a diesel-contaminated soil (initial diesel concentration: 2,000 mg/kg, 5,000 mg/kg, and 10,000 mg/kg) with hydrogen peroxide (35%) only was containing natural-occurring minerals. The time required for the column test was approximately 90min, 180min, 270min; column length was 5 em, 10 em, and 15 em. The most effective stoichiometry (final diesel cone.: $200{\sim}300mg/kg$) of 0.2 g peroxide consumed/mg diesel degraded. Further investigation is required to identify the effect of soil organic matter and soil mineral.

Evaluation of Nanoscale Zero-valent Iron for Reductive Degradation of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX): Batch and Column Scale Studies (Hexahydro-1,3,5-trinitro-1,3,5-triazine(RDX)의 환원적 분해를 위한나노영가철의 성능평가: 회분식 및 칼럼 실험)

  • Lee, Chung-Seop;Oh, Da-Som;Cho, Sung-Heui;Lee, Jin-Wook;Chang, Yoon-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.117-126
    • /
    • 2015
  • Reductive degradation of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by nanoscale zero-valent iron (nZVI) was investigated to evaluate the feasibility of using it for in-situ groundwater remediation. Batch experiments were conducted to quantify the kinetics and efficiency of RDX removal by nZVI, and to determine the effects of pH, dissolved oxygen (DO), and ionic strength on this process. Experimental results showed that the reduction of RDX by nZVI followed pseudo-first order kinetics with the observed rate constant (kobs) in the range of 0.0056-0.0192 min−1. Column tests were conducted to quantify the removal of RDX by nZVI under real groundwater conditions and evaluate the potential efficacy of nZVI for this purpose in real conditions. In column experiment, RDX removal capacity of nZVI was determined to be 82,500 mg/kg nZVI. pH, oxidation-reduction potential (ORP), and DO concentration varied significantly during the column experiments; the occurrence of these changes suggests that monitoring these quantities may be useful in evaluation of the reactivity of nZVI, because the most critical mechanisms for RDX removal are based on the chemical reduction reactions. These results revealed that nZVI can significantly degrade RDX and that use of nZVI could be an effective method for in-situ remediation of RDX-contaminated groundwater.

An Experimental Study on the Determination of Minimum Response Concentration of Inorganic Pollutants in Tap Water (수돗물에서 무기 오염물질 최소 반응 농도 결정의 실험적 고찰)

  • Yoon, Sukmin;Kim, Seong-Su;Chea, Seon-Ha;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.208-213
    • /
    • 2017
  • In this study, four inorganic pollutants (cadmium, chromium, manganese, lead), that could cause contamination events in drinking water distribution system, were selected and batch tests were carried out to determine the "minimum response concentration (MRC)", a part of Korean Contamination Warning system establishment. As the results, the minimum response concentration of cadmium was found to be 0.05 to 0.08 mg/L (0.005 mg/L : water quality standard) and that of chrome was 0.03 mg/L (0.05 mg/L). And the minimum reaction concentration was 0.005 mg/L for manganese (0.05 mg / L for water quality) and 0.02~0.08 mg/L for lead (0.01 mg/L).

Characteristics of Nutrients Removal Process Activating Soil Microorganisms and Phosphorus Uptake under Anoxic Condition(II) (토양미생물을 활성화한 영양염류 제거 공정의 특성과 무산소 조건에서의 인 섭취(II))

  • Shin, Eung-Bae;Ko, Nam-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1757-1763
    • /
    • 2000
  • To consider the nutrient removal characteristics of BNR process activating soil microorganisms under the influence of DPB and to clear the characteristics of DPB under anoxic condition was investigated in the this study. The batch tests were conducted using sludge sampled from the BNR process activating soil microorganisms during operation periods. The results of this study were summarized as follows: - The DPB(Denitrifying Phosphorus removing Bacteria) performing denitrification and phosphorus uptake in the anoxic phase plays an important role in removing nitrogen and phosphorus in the BNR process activating soil microorganisms. - The PUR(Phosphorus Uptake Rate) of DPB in the anoxic phase was to be about 50% of PUR in the aerobic phase. - The DPB in the BNR process turned out to be increasing nutrient removal efficiency of BNR process.

  • PDF

Hydrogen Production and Organic Removal according to Mixture Ratio of Food Wastewater and Swine Wastewater using Anaerobic Batch Reactor (회분식 혐기성 소화 반응기에서 음식물탈리액과 양돈폐수의 혼합비에 따른 수소 생산 및 유기물 제거)

  • Kim, Choong-Gon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.641-647
    • /
    • 2007
  • This study aims to find out optimum condition for hydrogen production and organic removal when treating food and swine wastewater together. For this purpose, various batch tests were conducted by changing mixture ratio from 6:4 (food wastewater:swine wastewater) to 1:9 without pretreatment process. For hydrogen production through anaerobic fermentation, the mixture ratios of R-1 (6:4), R-2 (5:5) and R-6 (1:9) were out of pH range appropriate for hydrogen production and mixture ratios of R-3 (4:6), R-4 (3:7), and R-5(2:8) showed appropriate hydrogen production where their pH ranges were 5.1~5.5. Especially in case of R-3, it consistently maintained appropriate pH range for hydrogen production for 72hr and produced maximum hydrogen. The characteristics of hydrogen production and cumulative hydrogen production according to each mixture ratio showed that R-1, R-2 and R-6 did not produce any hydrogen, and maximum hydrogen productions of R-3, R-4 and R-5 were 593ml, 419ml and 90ml, respectively. Total cumulative hydrogen productions of R-3, R-4 and R-5 were 1690ml, 425ml and 96ml, respectively. Based on previous results, it was concluded that, the most appropriate mixture ratio of food wastewater and swine wastewate rwas 4:6 (R-3). The experiment for COD removal rate to evaluate organic removal efficiency revealed that R-3, R-4 and R-5 showed high removal efficiencies during the highest hydrogen production amount and the highest efficiency was 41% with R-3.

Reduction of Nitrate using Nanoscale Zero-Valent Iron Supported on the Ion-Exchange Resin (이온교환 능력을 가진 지지체에 부착된 나노 영가철을 이용한 질산성 질소의 환원과 부산물 제거)

  • Park, Heesu;Park, Yong-Min;Jo, Yun-Seong;Oh, Soo-Kyeong;Kang, Sang-Yoon;Yoo, Kyoung-Min;Lee, Seong-Jae;Choi, Yong-Su;Lee, Sang-Hyup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.679-687
    • /
    • 2007
  • Nanoscale zero valent ion (nZVI) technology is emerging as an innovative method to treat contaminated groundwater. The activity of nZVI is very high due to their high specific surface area, and supporting this material can help to preserve its chemical nature by inhibiting oxidation. In this study, nZVI particles were attached to granular ion-exchange resin through borohydride reduction of ferrous ions, and chemical reduction of nitrate by this material was investigated as a potential technology to remove nitrate from groundwater. The pore structure and physical characteristics were measured and the change by the adsorption of nZVI was discussed. Batch tests were conducted to characterize the activity of the supported nZVI and the results indicated that the degradation of nitrate appeared to be a pseudo first-order reaction with the observed reaction rate constant of $0.425h^{-1}$ without pH control. The reduction process continued but at a much lower rate with a rate constant of $0.044h^{-1}$, which is likely limited by mass transfer. To assess the effects of other ions commonly found in groundwater, the same experiments were conducted in simulated groundwater with the same level of nitrate. In simulated groundwater, the rate constant was $0.078h^{-1}$ and it also reduced to $0.0021h^{-1}$ in later phase. The major limitation in application of ZVI for nitrate reduction is ammonium production. By using a support material with ion exchange capacity, the problem of ammonium release can be solved. The ammonium was not detected in the batch test, even when other competitive ions such as calcium and potassium existed.

Studies on the Manufacturing of Carbon Bond Graphite Crucible (카아본 본드형 흑연 도가니 제조에 관한 연구)

  • 김충일;김문수
    • Journal of the Korean Ceramic Society
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1976
  • This study was focused on the improvement of production techniques of small crucibles in relation with the appropriate selection of raw materials, various batch compositions and physical and chemical characteristics of the crucibles. Various tests gave the optimum batch composition for the carbon bond graphite cructble as follows: Pyontaek graphite flake (refractory aggregate) : 40Part Silicon carbide: 15Part Tar pitch (binder) : 11Part Inorganic additives (to improve the oxidation resistance) : 15 Part Cryolite : 3 Part Ferro manganese : 2 Part Ferrosilicon : 25 Part Crucibles pressed with 400kg/$\textrm{cm}^2$ at 12$0^{\circ}C$. and fired in reducing atmosphere at 120$0^{\circ}C$ brought the most favorable results as follows: Bulk density : 2.31 Apparent density : 2.58 Porosity : 15.2% Oxidation loss at 1, 50$0^{\circ}C$. for 3 hrs : below 3.77% Water absorption : 6.01% Compressive strength : 438kg/$\textrm{cm}^2$ Tensile strength : 256kg/$\textrm{cm}^2$.

  • PDF

Adsorption of Cu(II) from Aqueous Solutions Using Pine (Pinus densiflora) Wood (소나무(Pinus densiflora) 목질을 이용한 수용액 중의 Cu(II) 흡착)

  • Kim, Ha-Na;Park, Se-Keun;Yang, Kyung-Min;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.195-202
    • /
    • 2007
  • Milled Korean pine (Pinus densiflora) wood was used to evaluate its adsorption capacity of Cu(II) ions from aqueous solution by running a series of batch experiments. Prior to the tests, the milled woods were pretreated with 1N NaOH, 1N $HNO_3$, and distilled water, respectively, to examine the effect of pretreatment. Within the tested pH range between 3 and 6, copper adsorption efficiency of NaOH-treated wood(96~99%) was superior to the $HNO_3$-treated wood(19~31%) and distilled water-treated wood(18~35%). The efficiency of copper removal by wood enhanced with increasing solution pH and reached a maximum copper ion uptake at pH 5~6. Adsorption behavior of copper onto both raw and $HNO_3$-treated woods was mainly attributed to interaction with carboxylic acid group. For NaOH-treated wood, carboxylate ion produced by hydrolysis or saponification was a major functional group responsible for Cu sorption. NaOH treatment of wood changed the ester and carboxylic acid groups into carboxylate group, whereas $HNO_3$ treatment did not affect the production of functional groups which could bind copper. A pseudo second-order kinetic model fitted well for the sorption of copper ion onto NaOH-treated wood. A batch isotherm test using NaOH-treated wood showed that equilibrium sorption data were better represented by the Langmuir model than the Freundlich model.

  • PDF