• 제목/요약/키워드: basic unit

검색결과 1,835건 처리시간 0.029초

표준품셈의 신뢰성에 대한 영향요인 분석 (An Analysis on the Influence Factors relative to Reliability of Standard Production Unit System)

  • 김용우;신원상;손창백
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.187-189
    • /
    • 2011
  • Standard production unit system has been used as accumulated standard for the cost estimation of public construction projects. However, it is difficult to estimate reasonable cost due to adaptation of a uniform standard and reflect changes in the technology. The purpose of this study is to provide basic data for improvement of standard production unit system through the identifying problems and analysing its influence on enactment and/or revision work of standard production unit system.

  • PDF

Gated Recurrent Unit 기법을 활용한 구조 안전성 평가 방법 (Evaluation Method of Structural Safety using Gated Recurrent Unit)

  • 강정호
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.183-193
    • /
    • 2024
  • Recurrent Neural Network technology that learns past patterns and predicts future patterns using technology for recognizing and classifying objects is being applied to various industries, economies, and languages. And research for practical use is making a lot of progress. However, research on the application of Recurrent Neural Networks for evaluating and predicting the safety of mechanical structures is insufficient. Accurate detection of external load applied to the outside is required to evaluate the safety of mechanical structures. Learning of Recurrent Neural Networks for this requires a large amount of load data. This study applied the Gated Recurrent Unit technique to examine the possibility of load learning and investigated the possibility of applying a stacked Auto Encoder as a way to secure load data. In addition, the usefulness of learning mechanical loads was analyzed with the Gated Recurrent Unit technique, and the basic setting of related functions and parameters was proposed to secure accuracy in the recognition and prediction of loads.

건설폐기물 재활용촉진을 위한 종류별 분류 및 발생원단위 산정 방안 (The method for the classification according to their kinds and the estimation of unit generation rate for promoting recycling of construction and demolition(c&d) debris)

  • 이희선;김동식
    • 한국재난정보학회 논문집
    • /
    • 제4권1호
    • /
    • pp.86-100
    • /
    • 2008
  • It is needed to classify the kinds of construction and demolition(c&d) debris to 6 catagories of waste concrete, waste asphalt concrete, waste wood, scraps, combustible waste and incombustible waste in order to properly do a separate discharge and to estimate unit generation rate in construction site. Also, in this case, the unit treating cost for mixed wastes should be applied with the unit treating cost for combustible waste. The construction standard materials estimation data is used for basic data for estimating unit generation rate. The mixed wastes in this data should be classified to waste wood, combustible waste and incombustible waste, and their ratio is obtained by using the unit generation rate of Asia Pacific Environment and Management Institute and Seoul Metropolitan Development Institute. The waste amounts generated from newly-built construction can be obtained from multiplying the loss rate by the amount of materials used from construction standard estimation data. Also, those from dismantling construction can be obtained by subtracting waste amount generated during newly-built construction from total input amount of materials in newly-built construction. Those in two cases can be used in construction site. It can be used for estimating the amount generated and establishing the treating plan in the case of setting up the policy of waste management and doing the environment impact assessment.

  • PDF

종합병원 혈관조영촬영유니트의 건축계획에 관한 연구 (A Study on the Architectural Planning of the Angiography Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권2호
    • /
    • pp.69-77
    • /
    • 2006
  • Angiography means that a check up to know an abnormal condition in all the blood vessels include from the heart, aortae, cerobrovascular and abdonominal artery to hands and feet. Main examples of this are cerebral angiography, abdominal, liver for urinary anomaly, renovascular angiography, and artery and vein in arms and legs. Angiography uses radial rays or angiography equipment for an image output during interventional procedure and compositive diagnosis. The acts which performed in a projection room have changed drastically. In general, it is performed by using equipment which is attached one or two C-arms and the method of inserting catheter in vein after anesthesia. For this reason, some rooms that consist of angiography room units should be planned not only for expensiveness equipment and facilities also to be germ-free. Nowadays, in the angiography unit case, it is placed independently as the central part of many hospitals. It does not belong to the imaging medical department any more as considering raising filming times and the relation between C.C.U.(coronary care unit) and operation unit. This means the acts performed are diversified and well-organized rooms in support of diagnosis are required. However, it is difficult to plan the angiography room unit due to domestic researches and data on this unit are not enough. Therefore, this study aims at bringing up basic issue for architectural planning of the angiography unit in general hospital.

  • PDF

기초간호자연과학의 병태생리학, 병원미생물, 약물의 기전과 효과 내용별 필요도에 대한 연구 (A study on the degree of need of the knowledge of pathophysiology, clinical microbiology and mechanisms and effects of drugs in clinical nurses)

  • 최명애;변영순;서영숙;황애란;김희승;홍해숙;박미정;최스미;이경숙;서화숙;신기수
    • Journal of Korean Biological Nursing Science
    • /
    • 제2권1호
    • /
    • pp.1-19
    • /
    • 2000
  • The purpose of this study was to define the content of the requisite knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs needed for clinical knowledge for nursing practice. Contents of knowlege on pathological physiology, clinical microbiology, and mechanisms and effects of drugs were constructed from syllabus of basic nursing subjects in 4 colleges of nursing, and textbooks. The degree of need of 72 items was measured with a 4 point scale. The subjects of this study were college-graduated 136 nurses from seven university hospital in Seoul and three in Chonnam Province, Kyungbook Province, and Inchon. They have been working at internal medicine ward, surgical ward, intensive care unit, obstetrics and gynecology ward, pediatrics ward, opthalmology ward, ear, nose, and throat ward, emergency room, rehabilitation ward, cancer ward, and hospice ward. The results were as follows : 1. The highest scored items of the knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs necessary for nursing practice were side effects of drugs, anticoagulants, mechanisms of drugs, antihypertensive drugs, tolerance and addiction of drugs, interactions among drugs, hospital infection in the order of importance. The lowest scored item was structure of microorganisms. 2. The highest order of need according to unit was repair in tissue injury unit, definition etiology classification of inflammation in inflammation unit, transplantation and immunologic response in alterations in immunity unit, thrombus and thrombosis in disorders of cardiovascular function unit, gene disorders in genetic disorders unit, hospital infection in infection unit, virus in microorganisms unit, side reactions of drugs in introduction unit, anticonvulsants in drugs for central nervous system unit, local anesthesia in anesthesia unit, anticoagulants in drugs for cardiovascular system unit, anti-inflammatory drugs in antibiotics unit, anti-ulcer drugs in drugs for digestive system unit, and bronchodilators in drugs for respiratory system unit. 3. The common content of the knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs needed for all clinical areas in nursing were side effects of drugs, anticoagulants, interactions among drugs, and hospital infection. However, the degree of need of each pathological physiology, clinical microbiology, clinical microbiology, and mechanisms and effects of drugs was different depending on clinical areas. 4. Significant differences in the knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs necessary for nursing practice such as tissue changes due to injurious stimuli, degenerative changes of tissue, alterations in metabolism of carbohydrates, ischemia, hyperemia and congestion, hospital infection, structure of microorganism, classification of microorganism, bacteria, virus, antidepressants, antipsychotic drugs, antiemetic drugs, antiparkinsonism drugs, antianxiety drugs, antibiotics, tuberculostatics, antiviral drugs, antifungal drugs, parasiticides, antiulcer drugs, antidiarrheais, and anti constipation drugs were shown according to the work area. 5. Significant differences in the knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs necessary for nursing practice such as transplantation and immunologic response, alterations in the metabolism of uric acid, structure of microorganism, classification of microorganism, immunosuppressants, drugs for congestive heart failure were demonstrated according to the duration of work. Based on these findings, all the 72 items constructed by Korean Academic Society of Basic Nursing science should be included as contents of the knowledge of pathophysiology, clinical microbiology, and mechanisms and effects of drugs.

  • PDF

개발사업지구의 공원 · 녹지 유형별 탄소효과 원단위 산정에 관한 기초연구 (A Study of Estimation of Carbon Effects per Unit Area by Park & Green Type in Development Project Area)

  • 강명수;김종림;김남정
    • 한국환경복원기술학회지
    • /
    • 제16권5호
    • /
    • pp.71-81
    • /
    • 2013
  • This study is aimed to provide basic data for the estimation of carbon effects in development project areas such as Happy Housing Project which includes redevelopment and reconstruction projects by inducing the basic unit of carbon effects and strategic planning and management to enhance carbon effects. According to the analysis, in urban parks, carbon uptake and carbon storage by the unit area of living area parks were $7.614kg/m^2$ and $18.5203kg/m^2$ respectively while carbon uptake and carbon storage by the unit area of theme parks were $1.2261kg/m^2$ and $2.831kg/m^2$ each. In facility greens, carbon uptake and carbon storage were $0.5683kg/m^2$ and $0.6636kg/m^2$ respectively while they were $10.77kg/m^2$ and $13.69kg/m^2$ individually in other urban planning facilities. In other greens, on the contrary, carbon uptake and carbon storage were $0.45kg/m^2$ and $1.02kg/m^2$ respectively. In site landscape, carbon uptake and carbon storage by the unit area of apartment landscape were $3.7394kg/m^2$ and $9.2292kg/m^2$ each.

음압격리병실에 있어서 단계별 공간구성의 격리효과 (Isolation Effectiveness by Progressive Space Organization in Negative Pressured Isolation Unit)

  • 권순정;성민기
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of Progressive Space Organization (ante-rooms) in Negative Pressured Isolation Unit(NPIU) such as National and Regional Isolation Units in Korea in order to build basic data for the evidence based design of Airborne Infection Isolation Units which should prepare and respond effectively to the public health crisis due to the hazardous airborne infectious disease. Methods: 1) Gas(SF6) test and analysis on the 23 Korean Isolation Units under operation. 2) Assessment of the isolation level of the space components by checking the Gas concentration. 3) Analysis of the Isolation Effectiveness according to Space Organizational levels. Results: 1) The higher segregation level is, the lower Gas(SF6) concentration is. 2) Too many segregations(anterooms) of Isolation Unit are not efficient for the prevention of infectious bacillus spread. For example, 4 level of segregation has similar segregation effect to the 3 level of segregation. Implications: Many anterooms in front of the isolated patient bedroom will guarantee the safe environment against the danger of hazardous airborne nosocomial infection. On the other hand, too many segregations is inefficient, expensive, inconvenient, narrow(unflexible) and so on. This study can be used as basic data for further development of design guidelines of isolation units.

Research on bearing characteristics of socket-spigot template supporting system

  • Guo, Yan;Hu, Chang-Ming;Lian, Ming
    • Steel and Composite Structures
    • /
    • 제20권4호
    • /
    • pp.869-887
    • /
    • 2016
  • The socket-spigot template supporting system is widely used in engineering applications in China. As a newer type of support structure, there has been growing research interest in its bearing capacity. In this paper, four vertical bearing capacity tests were carried out on the basic mechanical unit frame of a socket-spigot template supporting system. The first goal was to explore the influence of the node semi-rigid degree and the longitudinal spacing of the upright tube on the vertical bearing capacity. The second objective was to analyze the displacement trend and the failure mode during the loading process. This paper presents numerical analysis of the vertical bearing capacity of the unit frames using the finite element software ANSYS. It revealed the relationship between the node semi-rigid degree and the vertical bearing capacity, that the two-linear reinforcement model of elastic-plastic material can be used to analyze the socket-spigot template supporting system, and, through node entity model analysis, that the load transfer direction greatly influences the node bearing area. Finally, this paper indicates the results of on-site application performance experiments, shows that the supporting system has adequate bearing capacity and stability, and comments on the common work performance of a socket and fastener scaffold.

다중모드 무단 변속기의 구조이론에 관한 연구 (Basic Theory on a Multi-Mode CVT)

  • 이진원;장욱진;박진호;박영일;이장무
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2477-2486
    • /
    • 2000
  • A planetary gear assembly is a key component to combine and/or split a power from the source. With a planetary gear assembly, a continuously variable unit extends its capacity by means of power bra nching mechanism. Power branching with one planetary gear assembly and one continuously variable unit is categorized into 12 basic types. Each type represents peculiar power transmitting characteristics. Additionally, a multi-mode (range) continuously variable transmission can be designed with accompanying clutches. A multi-mode continuously variable transmission changes the path through which the source power is transmitted. Each path has its own features, such as high efficiency. In this paper, some design principles are examined such as, criteria to guarantee the minimum power efficiency, and constraints to guarantee the smooth mode shift after discussing well-known features of multi-mode M mathematically.

역대(歷代) 약물(藥物) 비표준(非標準) 계량단위(計量單位)의 고찰(考察) (A Historical Study of Non-standard Weight and Measuring Units)

  • 윤성중;문영춘;김지훈;정기은;김윤경
    • 대한한의학방제학회지
    • /
    • 제24권4호
    • /
    • pp.335-351
    • /
    • 2016
  • Objective : This study was done to clarify ambiguous non-standard weight and measuring units in medical classics. Methods : Using medical classics and research dissertations, we studied the basic definitions of weight and measuring units and the types of non-standard weight and measuring units. We compared non-standard weight and measuring units in the reference literatures, to determine the dose of herbs in the prescriptions. Results : There are three types of units in non-standard weight and measuring units. These are 'Quantity measuring unit', 'Resembrance measuring unit', and 'Eye measuring unit'. And we found historical efforts and progresses for proper ways to convert non-standard weight and measuring units to standard weight and measuring units. Conclusions : This research will be the basic data for the standardization of prescriptions. Additional study was still required for precise weighing and measuring in Korean medicine and pharmacy.