• Title/Summary/Keyword: basic optics

Search Result 211, Processing Time 0.026 seconds

Endoscopic Spine Surgery

  • Choi, Gun;Pophale, Chetan S;Patel, Bhupesh;Uniyal, Priyank
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.485-497
    • /
    • 2017
  • Surgical treatment of the degenerative disc disease has evolved from traditional open spine surgery to minimally invasive spine surgery including endoscopic spine surgery. Constant improvement in the imaging modality especially with introduction of the magnetic resonance imaging, it is possible to identify culprit degenerated disc segment and again with the discography it is possible to diagnose the pain generator and pathological degenerated disc very precisely and its treatment with minimally invasive approach. With improvements in the optics, high resolution camera, light source, high speed burr, irrigation pump etc, minimally invasive spine surgeries can be performed with various endoscopic techniques for lumbar, cervical and thoracic regions. Advantages of endoscopic spine surgeries are less tissue dissection and muscle trauma, reduced blood loss, less damage to the epidural blood supply and consequent epidural fibrosis and scarring, reduced hospital stay, early functional recovery and improvement in the quality of life & better cosmesis. With precise indication, proper diagnosis and good training, the endoscopic spine surgery can give equally good result as open spine surgery. Initially, endoscopic technique was restricted to the lumbar region but now it also can be used for cervical and thoracic disc herniations. Previously endoscopy was used for disc herniations which were contained without migration but now days it is used for highly up and down migrated disc herniations as well. Use of endoscopic technique in lumbar region was restricted to disc herniations but gradually it is also used for spinal canal stenosis and endoscopic assisted fusion surgeries. Endoscopic spine surgery can play important role in the treatment of adolescent disc herniations especially for the persons who engage in the competitive sports and the athletes where less tissue trauma, cosmesis and early functional recovery is desirable. From simple chemonucleolysis to current day endoscopic procedures the history of minimally invasive spine surgery is interesting. Appropriate indications, clear imaging prior to surgery and preplanning are keys to successful outcome. In this article basic procedures of percutaneous endoscopic lumbar discectomy through transforaminal and interlaminar routes, percutaneous endoscopic cervical discectomy, percutaneous endoscopic posterior cervical foraminotomy and percutaneous endoscopic thoracic discectomy are discussed.

Effect of the Thermal Lensing on stable Region, Beam Waist and Astigmatic Compensation of Z-fold Cr4+ : YAG laser Cavity (Cr4+ : YAG 레이저에서 열 렌즈 효과에 따른 공진기의 안정영역과 빔 허리 및 비점수차의 보상)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.447-454
    • /
    • 2006
  • We obtained analytic solutions of boundary conditions to the stable region of Z-fold $Cr^{4+}$ : YAG laser cavity when the conditions are with and without thermal tensing effect. Also we investigated the influence of the thermal tensing effect on the stability of cavity, beam waist, and astigmatic compensation using aberration transformation matrices. The thermal tensing effect almost has no influence on the stable region of the cavity when the crystal is located in the middle of two concave mirrors and when the distances from the concave mirror to the reflecting mirror and the output coupler are the same. The beam waist, however, is affected more in a tangential plane than in a sagittal plane, and so it is difficult to have astigmatic compensation when the thermal tensing effect exists. This result means that the thermal tensing effect should be considered even for the Kerr-lens mode-locking.

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.

GRINDING OPTIMIZATION MODEL FOR NANOMETRIC SURFACE ROUGHNESS FOR ASPHERIC ASTRONOMICAL OPTICAL SURFACES (천체망원경용 비구면 반사경 표면조도 향상을 위한 최적연삭변수 수치결정모델)

  • Han, Jeong-Yeol;Kim, Sug-Whan;Kim, Geon-Hee;Han, In-Woo;Yang, Sun-Choel
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 2005
  • Bound abrasive grinding is used for the initial fabrication phase of the precision aspheric mirrors for both space and ground based astronomical telescopes. We developed a new grinding optimization process that determines the input grinding variables for the target surface roughness, checks the grinding error magnitude in resulting surface roughnesses, and minimizes the required machining time. Using the machining data collected from the previous grinding runs and subsequently fed into the multivariable regression engine, the process has the evolving controllability that suggests the optimum set of grinding variables for each target surface roughness. The process model was then used for ten grinding experiments that resulted in the grinding accuracy of $=-0.906{\pm}3.38(\sigma)\;nm(Ra)$ for the target surface roughnesses of Zerodur substrate ranging from 96.1 nm (Ra) to 65.0 nm (Ra) The results imply that the quantitative process optimization technique developed in this study minimizes the machining time and offers the nanometric surface roughness controllability superior to the traditional, qualitative, craftsman based grinding process for the astronomical optical surfaces.

Multiphonon relaxation and frequency upconversion of $Er^{3+}$ ions in heavy metal oxide glasses ($Er^{3+}$첨가 중금속 산화물 유리의 다중포논 완화와 주파수 상향 전이 현상)

  • Choi, yong-Gyu;Kim, Kyong-Hon;Heo, Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.221-226
    • /
    • 1998
  • Ternary heavy metal oxide glasses in the $PbO-Bi_2O_3-Ga_2O_3$ system doped with $Er_2O_3$ were prepared and their spectroscopic properties, such as radiative transition probability, calculated and measured radiative lifetimes and cross-sections of 1.5 $\mu\textrm{m}$ and 2.7 $\mu\textrm{m}$ emissions were analyzed. Enhanced quantum efficiencies of some electronic transitions were evident mainly because of the low vibrational phonon energy ($~500cm^{-1}$) inherent in the host glasses. This seems to be the main reason for obtaining the 2.7 $\mu\textrm{m}$ luminescence which is normally quenched in the conventional oxide glasses. In addition, green and red fluorescence emissions were observed through the frequency upconversion processes of the 798 nm excitation. Non-radiative transition due to the multiphonon relaxation is a dominant lifetime-shortening mechanism in the 4f-4f transitions in $Er^{3+}$ ion except for the $^4S_{3/2}{\rightarrow}^4I_{15/2}$ transition where a non-radiative transfer to band-gap excitation of the host glasses is dominant. Melting of glasses under an inert gas atmosphere and (or) addition of the typical glass-network former into glasses is necessary in order to enhance the quantum efficiency of the transition.

  • PDF

The Food Safety of Superfine Powder (Phellinus linteus) Processed by Nanomill in C57BL/6 Mice (C57BL/6 마우스에서 나노밀 가공된 초미세분말(상황버섯)의 식이 안전성 연구)

  • Kim, Dong-Heui;Teng, Yung-Chien;Yoon, Yang-Sook;Qi, Xu-Feng;Jeong, Hyun-Seok;Joo, Kyung-Bok;Lee, Kyu-Jae
    • Applied Microscopy
    • /
    • v.39 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • A officinal mushroom, Phellinus linteus (PL) has been known to exhibit potent biological activities including antioxidative and anticancer effect. PL is consumed as a type of powder or extract for the purpose of health promotion and disease treatment. Recently superfine PL products was commercialized according to the development of pulverizing technology such as nanomill, so the evaluation of food safety is suggested. This study was conducted to evaluate the food safety of superfine PL (SPL) through hematological, biochemical and histological examination in mice as compared with fine PL (FPL). In the particle size distribution in volume after nanomill processing, the mean diameter of SPL and FPL particles was 11.78 ${\mu}m$ and 216.1 ${\mu}m$, and d (0.5), the particle diameter measured at 50% of distribution was 5.5 ${\mu}m$ and 147.9 ${\mu}m$, respectively. As the result of body weight, food intake and the weight of organs, SPL group didn't show any statistical difference compared with FPL group and normal group (N). Hematological and biochemical values were also involved in the normal range, although ALT (N vs. FPL, P<0.001) and BUN (N vs. FPL, P<0.01; N vs. SPL, P<0.01) showed significance compared with N group but there are no significance between FPL and SPL group. In the result of histological examination with liver, kidney, spleen, and small and large intestine, abnormal findings such as inflammatory reaction and histological changes were not observed. Our results suggest that the oral intake of SPL diet is not harmful to the animal in the hematological, biochemical and histological aspects although particle size was reduced to the level of superfine. However, further study will be necessary to confirm the histological safety in relation to the gastrointestinal contact of superfine particles in the case of large amount and long-term intake.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Physical Properties of the Hydrogel Using Alginate (Alginate가 포함된 하이드로겔의 물리적 특성)

  • Woo, Chul-min;Heo, Seongin;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.463-469
    • /
    • 2015
  • Purpose: A hydrogel including alginate and $CaCl_2$ extracted from seaweed was manufactured, and their physical properties were investigated. Also, its applicability as contact lenses was examined. Methods: A film-type sample used in this experiment was manufactured using 2-hydroxyethyl methacrylate (HEMA), which is the raw material of hydrogel contact lenses; azobisiobutyonitile (AIBN), which is an initiator and ethylenglycoldimethacrylate (EGDMA), which is a cross-linking agent. It was hydrated in a PBS solution for 24 hours, and an interpenetrating polymer network (IPN) was formed in 1% and 2% alginate and 1%, 3%, and 5% $CaCl_2$ solutions for 24 hours, respectively. Results: The measurement of the physical properties of the film after the IPN showed that the moisture content was 30.89~36.89%, the refractive index was 1.431~1.441, the contact angle was $62.98{\sim}80.45^{\circ}$, and the tensile strength was 2.378~4.215 ($gf/mm^2$). Also, the physical properties hardly changed as the content of alginate increased, and the moisture content decreased as the content of $CaCl_2$ increased. As a result of the IPN, the moisture content and contact angle decreased compared to those of basic HEMA, but the tensile strength increased. The tensile strength of the second IPN was higher than that of the first IPN. In the case of $CaCl_2$, for the sample polymerized for 24 hours and the second IPN sample with 2% alginate, the contact angle decreased as the content of $CaCl_2$ increased. Conclusions: In this study, the tensile strength increased as the content of $CaCl_2$ increased, and the wettability increased as a result of IPN of alginate and $CaCl_2$. The hydrogel containing the alginate and $CaCl_2$ was confirmed possible utilization as contact lens material.

Design and characterization of conductive transparent filter using [TiO2|Ti|Ag|TiO2] multilayer ([TiO2|Ti|Ag|TiO2] 다층구조를 이용한 전도성 투과필터의 설계 및 특성분석)

  • Lee, Seung-Hyu;Lee, Jang-Hoon;Hwangbo, Chang-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.363-369
    • /
    • 2002
  • We have designed conductive transparent filters using a low-emissivity coating such as [dielectric|Ag|dielectric] for display applications. The design is the repetition of [$TiO_{2}$|Ti|Ag |$TiO_{2}$] to increase the transmittance in the visible and decrease the transmittance in the near IR. The conductive transparent filters are deposited by a radio frequency(RF) magnetron sputtering system. The optical, structural and electrical properties of the filters were investigated and the optical spectra are compared with simulated spectra. The thickness of the deposited Ag films is above 13 ㎚ to increase the conductivity and that of $TiO_{2}$ films is 24 ㎚ to increase the transmittance in the visible range. Ti blockers are employed to prevent the Ag films from being oxidized by an oxygen gas during the reactive sputtering process. Also, it is shown that the thicker Ti film is necessary as the period increases. Finally, a filter with repetition of the basic structure three times shows the better cut-off near infrared(NIR) and the sheet resistance as low as 2Ω/□ which is enough to shield an unnecessary electromagnetic waves for a display panel.