• Title/Summary/Keyword: base leakage

Search Result 161, Processing Time 0.024 seconds

A TRANSFORMER-LESS SINGLE PHASE INVERTER USING A BUCK-BOOST TYPE CHOPPER CIRCUIT FOR PHOTOVOLTAIC POWER SYSTEM

  • Kasa, Nobuyki;Iida, Takahiko
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.978-981
    • /
    • 1998
  • This paper presents a newly developed transformer-less single phase inverter for a photovoltaic (PV) power system. In the proposed system, there is no earth-leakage current at all in the theoretical base, and the main circuit of this system is rather simple and it is expected the higher efficiency will be realized. The system is operated by a digital signal processor (DSP) which makes it more flexible in the control. From the experimental results, it is found that this new inverter supplies the AC power to utility grid line with the power factor of nearly unity.

  • PDF

A Study on the Simulation of Leak Flow-rate Using Isothermal Chamber (등온화용기를 이용한 누설유량 시뮬레이션에 관한 연구)

  • Ji, S.W.;Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.71-75
    • /
    • 2010
  • Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.

Transient Simulation Studies of Squirrel-Cage Induction Motor Directly Supplied with Aircraft Variable Frequency Power

  • Du, Xiaofei;Wang, Deqiang;Zhou, Yuanjun
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Aircraft variable frequency power and a new application of induction motor under the aero-power are introduced. The transient models and simulation of induction motor are reviewed. A new transient model and simulation method is presented that includes deep-bar effect and magnetic saturation. Dynamic magnetizing inductance, rotor resistance and leakage reactance are considered as varying parameters in state-space model. Base on known rotor structure and speed, these parameters can be calculated.

Determination the appearance coefficients of Linear Homopolar Synchronous Motor for Integrated Suspension/Propulsion System (자기부상 및 추진일체형 LHSM의 자기형상계수 산정)

  • Jang, S.M.;Jeong, S.S.;Lee, S.L.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.281-283
    • /
    • 1998
  • The 4-poles LHSM with transverse bar track was designed on the base of the performance equations and the equivalent circuit model. However, the magnetic shape factors, such as Carter's and Green's coefficients, $B_{min}/B_{max}$ and leakage factors, were important in the design and analysis of LHSM. Consequently, these coefficients were computed from the analytical expressions and examined from FEM analysis in detail.

  • PDF

Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases (룰 베이스를 이용한 공조기의 고장검출 및 진단)

  • 한도영;주명재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

Cause Analysis for a Lining Damage in Sea Water System Piping Installed in a Korean Industrial Plant

  • Hwang, K.M.;Park, S.K.
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Many Korean industrial plants including nuclear and fossil power plants use seawater as the ultimate heat sink to cool the heat generated by various facilities. Owing to the high corrosivity of seawater, facilities and piping made of metal material in contact with seawater are coated or lined with polymeric materials to avoid direct contact with seawater. However, polymeric materials used as coating and lining have some level of permeability to water and are degraded over time. Korean industrial plants have also experienced a gradual increase in the frequency of damage to pipes in seawater systems due to prolonged operating periods. In the event of a cavitation-like phenomenon, coating or lining inside the piping is likely to be damaged faster than expected. In this paper, the cause of water leakage due to base metal damage caused by the failure of the polyester lining in seawater system piping was assessed and the experience with establishing countermeasures to prevent such damage was described.

NUMERICAL ANALYSIS FOR FLOW CHARACTERISTICS WITH GEOMETRIC SHAPE AND CONTROL CONDITIONS IN SUBSEA BY-PASS VALVE (심해저 바이패스 밸브의 기하학적 형상과 제어조건에 따른 유동특성에 관한 수치해석적 연구)

  • Lee, J.H.;Min, C.H.;Oh, J.W.;Cho, S.;Kim, H.W.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2016
  • The present study has been carried out to analyze the flow characteristics with geometric shape and control conditions in subsea by-pass valve. The function of by-pass valve is to prevent reverse flow. In this study, the static analysis has been perform for analyzing fluid flow in open state. In order to consider the turbulent effect, the standard ${\kappa}-{\varepsilon}$ model was used. A variety of parametric studies, such as by-pass valve type or size, volume flow rate, leakage hole size, leakage hole position, block type, block shape, were performed. The pressure difference across the valve in the model broadened the flow channel cross-sectional area was greater than the base model for the same operating conditions. As the pipe diameter in the block decreases the pressure difference is greatly increased. The pressure difference according to block shape such as edge type and round was almost negligible. For the same Reynolds number the pressure difference was little changed according to the size of the valve.

A High Efficiency Reconfigurable Doherty Amplifier (고효율의 재구성된 도허티 증폭기)

  • Kim, Ell-Kou;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.3
    • /
    • pp.220-226
    • /
    • 2008
  • This paper proposes the Reconfigurable Doherty Amplifier(RDA) with asymmetric structure which has ${\lambda}/4$ impedance transformer for modulating the load impedance in peaking amplifier path. This structure is possible to implement a compact size for N-stage multi Doherty amplifier and to get almost same characteristics that is compared to conventional Doherty amplifier. To realize the high efficiency amplifier, we were implemented 45 Watts power amplifier at transmitter band of Wideband Code Division Multiple Access(WCDMA) base-station. As a result, in case of WCDMA 1 Frequency Allocation(FA) input signals, this amplifier has obtained a 26.3% Power Added Efficiency(PAE) at 8 dB back-off point from P1dB and an Adjacent Channel Leakage Power(ACLR) is -40.4 dBc at center frequency ${\pm}5MHz$ deviation.

  • PDF

Anonymity Certification Technique of a Smart Card base for Personal Information Protection (개인정보보호를 위한 스마트카드 기반의 익명 인증 기법)

  • Lee, Kwang-Hyoung;Park, Jeong-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6071-6080
    • /
    • 2012
  • Regarding the official authentication method which is a strong encrypt method for financial transactions, there has recently been a concern for the problem of storage. As a solution for such problems, this study provides the anonymous authentication method based on the smart card used for such a purpose by utilizing the pseudo ID replacing the user's personal data. Such an anonymous authentication method makes it possible to prevent any inside leakage, intermediary attack, limited re-transmission attack, service-denying attack, directional safety attack and secret inspector attack in regard to the user's personal data. As a result, there would be no concern for the leakage of any personal data. In comparative analysis, after executing the comparison and analysis process through the experiment for the authentication process by using the previously-used smart card, the new one has shown about 10% a high level of efficiency for the encrypt and decrypt process together with excellent features in terms of flexibility in regard to the user's anonymity and tracking ability.

A Study on the Selection System of Waterproof Method by Using Database (데이터베이스화에 의한 지수공법 선정시스템에 관한 연구)

  • 천병식;최춘식;하광현
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.43-59
    • /
    • 2002
  • In this study, database systems which were used to select the waterproof method according to leakage patterns of underground structures were built by performing pilot tests, reviewing literatures, and analysing the gathered data statistically. The database was built by using check lists which consisted of 5 major items and 73 subdivided items, and 26 major parameters according to 4 classified grades were determined on the base of survey which considered various in-situ conditions. The database of waterproof methods was comprised of 10 methods which were applied in Korea. From the database of waterproof methods, application ranges and design conditions of waterproof methods were suggested. From the results of study, database system consists of parameters selection database, waterproof method database, and design condition database. From the results of pilot tests, when the database of waterproof methods was applied to design stage, saving time and reducing mistakes for selecting waterproof method were gained. In addition, when the database of waterproof methods was applied to construction stage, effects such as evaluation of applicability of waterproof method, improvement of constructability and post management were expected.