Abstract
Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.
Keywords
Numerical Simulation; Leak Flow-rate; Isothermal Chamber; Stop Method; Compressible Fluid;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 J. P. Holman, 1997, "Heat Transfer(8th Edition)", McGraw-Hill, Inc(New York).
2 ISO 6358, 1989, "Pneumatic fluid power - Components using compressible fluids - Determination of flow-rate characteristics", International Organization for Standardization.
3 ISO 2533, 1975, "Standard Atmosphere", International Organization for Standardization.
4 S. T. Chapra, 2008, "Applied Numerical Methods with MATLAB for Engineers and Scientists", McGraw-Hill, Inc(New York).
5 A. Pourmovahed and D. R. Otis, 1990, "An experimental Thermal Time-Constant Correlation for Hydraulic Accumulators", ASME Jounal of Dynamic Systems, Measurement, and Control, Vol. 112, pp. 116-121.   DOI
6 강보식 외 4인, 2009, "크랭크 레버형 평행개폐 공기압 척의 수명분석", 한국정밀공학회, 제26권, 제9호, pp. 96-102.   과학기술학회마을
7 F. B. Daniels, 1947, "Acoustical Impedance of Enclosures", The Journal of the Acoustical Society of America, Vol. 19, No. 4, pp. 569-571.   DOI
8 ISO 19973, 2007, "Pneumatic fluid power - Assessment of component reliability by testing", International Organization for Standardization.
9 지상원, 장지성, 2007, "공기압시스템의 누설유량 계측법", 유공압시스템학회논문집, 제4권, 제3호, pp. 33-37.
10 S. W. Ji, J. S. Jang and T. Kagawa, 2008, "The Error Analysis of Leak Measurement for Pneumatic Cylinder using Isothermal Chamber", Jounal of the Korea Fluid Power Systems Society, Vol. 5, No. 1, pp. 6-12.   과학기술학회마을