• Title/Summary/Keyword: base leakage

Search Result 161, Processing Time 0.024 seconds

Development of Leakage-free Automatic Discharge Connector in a Submersible Pump. (수중펌프의 Leakage-free 자동탈착장치 개발)

  • Choi, Young-Seok;Lee, Kyoung-Yong;Lee, Chang-Han;Lee, Jong-Hun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.23-28
    • /
    • 2003
  • ADC (Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation make a leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested, and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF THE POSTERIOR COMPOSITE RESTORATIONS (구치부 복합레진의 변연누출에 관한 실험적 연구)

  • Kwon, Byeong-Goo;Lee, Chung-Suck;Park, Dong-Soo;Lee, Seung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.44-56
    • /
    • 1990
  • This study was designed to assess the degree of the marginal leakage of posterior composite restorations with glass ionomer cement base and Scotchbond$^{(R)}$ by means of the dye penetration at the enamel and dentinal margins. 160 cavities of class V were prepared on the buccal and lingual surfaces of 80 extracted premolar and molar teeth, which were divided into two groups. The buccal cavities of one group were filled with GC lining cement$^{(R)}$, Scotchbond$^{(R)}$ and P 50$^{(R)}$ and the lingual cavities were filled with Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$. The Buccal cavities of other group were filled with Logobond$^{(R)}$, Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$ and lingual cavities were filled with Scotchbond$^{(R)}$ and P 50$^{(R)}$. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$ and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours and buccolingually sectioned with diamond disc. The sectioned specimens were examined under light microscope. The following results were obtained. 1. The group filled with glass ionomer cement base showed less marginal leakage than the group filled without glass ionomer cement base. 2. The enamel margins showed less microleakage than the dentinal margins in both of the two groups. 3. No significant difference was showed in the microleakage, irrespective of two glass ionomer cement base and posterior composite resin.

  • PDF

A STUDY ON THE EFFECT OF BASE MATERIALS TO PROTECT THE CERVICAL LEAKAGE OF BLEACHING AGENTS (표백제의 치경부 누출을 방지하기 위한 각종 이장재의 효과에 관한 연구)

  • Song, Byeong-Choon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.585-601
    • /
    • 1994
  • The purpose of this study was to evaluate the ability of several intracoronal base materials to prevent cervical leakage of a bleaching agent into the dentinal tubules and along the root canal. In this study, thirty-two anterior teeth were used. After lingual access was prepared in each tooth, tooth was instrumented with a step-back technique to a Nos. 40-50 using K-type files. All teeth were obturated with a lateral condensation technique. Excess gutta percha was removed with a warm instrument to the facial level of the CEJ. Teeth were divided into four groups : Teeth in control group were not filled with base material. Teeth in groups 1, 2, and 3 had 2mm of gutta percha removed with a warm instrument, then Dycal, Fuki II LC and Z-100 were filled with palstic instruments on the top of the gutta percha respectively. All teeth were bleached for 7 days, fresh bleach was added for another 7 days, then a 10 % methylene blue dye was placed inside the access preparation. They were stored at $37^{\circ}C$ and $100^{\circ}C$ humidity for 5 days. Each tooth was sectioned perpendicular to the long axis using a diamond disk. Initial cuts were made at the most coronal level of facial and lingual CEJ's, then another cuts continued appically in the levels of 0.5mm, 1.5mm, and 2.0mm respectively. The amount of dye leakage through the dentinal tubules was determined at each cut section. In addition, when the cut specimen was determined to be last penetration of any dye, this level was recorded as depth of apical leakage from the coronal terminus of the gutta percha, Dycal, Fuji II LC and Z-100. The acquired data were analyzed by Tukey's Multiple Range Test adn Cochran-Mantel-Haenszel Test to see if there was any statistically significant difference in dye penetration and linear apical leakage among the groups. The results were as follows : 1. Control group at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 AND 3 at level of 2.0mm showed the least dye penetration through the facial or lingual dentinal tubules, but there were no significant difference among three groups. 2. Group 2 at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 and 3 at level of 2.0mm showed the least dye penetration through the proximal dentinal tubules, but there were no significant difference among control group, group 2, and group 3. 3. Group 1 showed the greatest dye penetration through the facial or lingual and proximal dentinal tubules at all levels, and there were significant difference with other three groups. 4. Control group and group 1 showed 2mm apical dye leakage at facial or lingual and proximal aspects, group 2 showed 1.5mm, and group 3 showed 0.5mm.

  • PDF

Through Flow Analysis and Leakage Flow of a Regenerative Pump (재생펌프의 유동해석 및 누설유동에 관한 연구)

  • Sim, Chang-Yeul;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1015-1022
    • /
    • 2003
  • Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy from the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting the performance of pump. A simple correlation was proposed using calculated leakage flows through the simplified passage. One dimensional analysis were made for the recirculating flow and angular momentum transfer using calculated three dimensional data base.

A Study on Development of Power Supply for High Frequency Induction Heating (고주파 유도가열용 전원장치의 개발에 관한 연구)

  • Lee, Bong-Seob
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.179-186
    • /
    • 2002
  • This paper proposed LC resonant current fed high frequency inverter for high frequency induction heating using leakage inductance of transformer and, its described operating principle. The analysis of circuit presented by using normalized parameter in considering leakage inductance of transformer and, discussed characteristic evaluation of inverter circuit in detail. The proposed inverter is operating ZVS to reduce turn-on and turn-off loss of switching devices so, raised an efficiency. And, the experimental apparatus was made on base characteristic evaluation of theoretical analysis to discuss possibility on high frequency source and confirmed a rightfulness theoretical analysis. A result of study, the proposed inverter is higher utilizing factor using on leakage inductance of transformer and show possibility, which is application on high frequency power system.

  • PDF

Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures (절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석)

  • Kim, Chang-Jong;Lee, Heung-Jae;Sin, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF

Evaluation of Corrosion Characteristics on Welding Part of Leakage Water Pipe by Underwater Welding Electrode (수중용접봉으로 용접한 누수 배관 용접부위의 부식 특성 평가)

  • Kim, Jin-Gyeong;Moon, Kyung-Man
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.93-94
    • /
    • 2006
  • The repair welding of small leakage parts on the water pipeline in engine room is often and important factor in standby and emergency condition in a ship. So, the purpose of this study is to evaluate the corrosion characteristics of welding part of leakage water pipe in case of some underwater welding electrodes. The corrosion current density between welding metal and base metal was considerably different according to used underwater welding electrodes. In case of DC welding, its corrosion characteristics was better than that of AC welding.

  • PDF

Shape Design Optimization of Inductive Position Sensor to Improve Sensitivity (유도형 변위 센서의 민감도 향상을 위한 형상 최적 설계)

  • 홍준희;이동주;신우철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.250-254
    • /
    • 2001
  • The resolution of analog sensor is determined by its sensitivity and amplitude of noise. This paper presents modeling of inductive gap sensor base on equivalent magnetic circuit and analysis of sensitivity. We can simulate static characteristic of inductive gap sensor using this model. Computer simulation show that sensor's sensitivity is affected by magnetic flux's leakage and fringing, and that they are affected by shape of sensor probe. Base on this, we designed shape of inductive position sensor probe.

  • PDF

Client Collaboration for Power and Interference Reduction in Wireless Cellular Communication

  • Nam, Hyungju;Jung, Minchae;Hwang, Kyuho;Choi, Sooyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • A client collaboration (CC) system is proposed for a user relay system. The proposed scheme focuses on the management of transmit power and leakage interference. In the proposed CC system, edge users transmit signals to the masters considered as user relays. The masters relay the signals of the edge users to the base station using the resource blocks (RBs) that are assigned to the edge users. The leakage interference and power consumption were analyzed in the CC system. In addition, an optimal master location problem was formulated based on the signal-to-leakage-plus-noise ratio (SLNR). Because the optimal master location problem is quite complex, a sub-optimal master location problem was proposed and a closed-form sub-optimal master location was obtained. The edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC. The numerical results showed that the edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC, and the average throughput increases.

  • PDF

공기분사를 이용한 라비린스 시일이 성능개선방안 연구

  • 나병철;전경진;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.04b
    • /
    • pp.153-157
    • /
    • 1996
  • A restrict jetting air is applied against leakage flow to improve a sealing performance of conventional labyrinth seal. A CFD analysis and sealing experiment are introduced to evaluate a sealing performance of applied model. The base of enhanced sealing is explained as a reducing clearance effect by jetting air. As a result, the applied model can improve the sealing performance of labyrinth seal in spite of the wide leakage clearance.

  • PDF