Browse > Article
http://dx.doi.org/10.5293/KFMA.2003.6.2.023

Development of Leakage-free Automatic Discharge Connector in a Submersible Pump.  

Choi, Young-Seok (한국생산기술연구원 신에너지환경팀)
Lee, Kyoung-Yong (한국기술교육대 대학원, 한국생산기술연구원)
Lee, Chang-Han (금정공업주식회사 기술연구소)
Lee, Jong-Hun (금정공업주식회사 기술연구소)
Publication Information
Abstract
ADC (Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation make a leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested, and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.
Keywords
Automatic Discharge Connector; Submersible Pump; Leakage Flow;
Citations & Related Records
연도 인용수 순위
  • Reference
1 /
[ ITT Industries ] / Flygt Submersible Pumps Catalog
2 /
[ Grundfos ] / Grundfos Sarlin Pumps Catalog
3 /
[ AEA Technology ] / CFX-TASCflow User Documentation
4 /
[ White, Frank M. ] / Fluid Mechanics