• 제목/요약/키워드: barrier-free

검색결과 415건 처리시간 0.025초

시각장애인 점자블록의 휘도대비 기준에 대한 연구 (A Study on Luminance Contrast Criteria for Tactile Walking Surface Indicators)

  • 신동홍;박광재;김상운
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권1호
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are the number of color tactile walking surface indicators installed in Korea, because of indefinite regulation in blind and vision-impaired persons' tactile walking surface indicators. In case of yellow tactile walking surface indicators, it shows a deviation severe color. In this study, the researchers suggested color and brightness reference for helping blind and vision-impaired persons' walking through analyzing the color references of tactile walking surface indicators and the color luminance between tactile walking surface indicators and sidewalk currently used. Method: Reasonable luminance contrast criteria is suggested by examining ways of improving the recognition and recognition of objects according to color contrast visually impaired through literature review and analyzing standards of tactile walking surface indicators and the Europe, Japan and Australia of color and luminance contrast criteria. And by examining the color of the tactile walking surface indicators reported in Korea currently used to derive the problem presented by the luminance contrast in the reference and comparison. Finally, the visually impaired tactile walking surface indicators is set for color selection criteria for the recognition rate improves. Results: In order to improve the recognition rate to be tactile walking surface indicators of the contrast of the visually impaired and the environment than the color of the tactile walking surface indicators itself to secure always a certain level or more of brightness contrast values in the set of the color of the tactile walking surface indicators so important. Implication: In order to set the blind tactile walking surface indicators color recognition based on the verification of the real pedestrian based on the results presented in this paper it is required. It is to be understood as an element of the barrier free configuration for securing the walking pedestrian safety.

숙박시설의 객실 유형에 따른 유니버설디자인 적용 방안에 대한 연구 - 장애인객실과 일반객실 유형비교·분석 및 FGI를 통하여 (A Study on the Application of Universal Design according to Room Types of Accommodation - Through classification and analysis of room types and FGI)

  • 류상오;김인순
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권3호
    • /
    • pp.29-37
    • /
    • 2017
  • Purpose : Due to the shortage of the room for the disabled, it may be difficult to use the accommodation for the disabled (especially wheelchair users). The purpose of this paper is to propose a universal design(UD) application for all rooms to solve the problems caused by the shortage and the decrease of the usage rate of the rooms for the disabled. Methods : Classify and analyze the type of room and bathroom according to the survey. The space of the room is classified into six types mainly based on the relation and location among the entrance, the bathroom, and the bedroom. Also, the bathroom is classified into 20 types considering the positional relationship with the entrance and between sanitary fixture. By using these types, FGI survey will be conducted and the application of UD will be reviewed and presented. Results : We analyzed by using the types of the room and the bathroom. One of majority type in the actual research and two of UD applicable types from FGI, are shown UD application. In addition, the bathroom were analyzed about four types from FGI. The room were shown about the activity space and the furniture layout for UD. The bathroom were shown about the space for the entrance, the internal activitiy space and the arrangement of the sanitary fixture. Implications : By comparing and analyzing through type classification, it was found that universal design can be applied to all rooms. Therefore, it is expected that the UD will be activated in all rooms of the accommodation.

Properties and SPICE modeling for a Schottky diode fabricated on the cracked GaN epitaxial layers on (111) silicon

  • 이헌복;백경흠;이명복;이정희;함성호
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.96-100
    • /
    • 2005
  • The planar Schottky diodes were fabricated and modeled to probe the device applicability of the cracked GaN epitaxial layer on a (111) silicon substrate. On the unintentionally n-doped GaN grown on silicon, we deposited Ti/Al/Ni/Au as the ohmic metal and Pt as the Schottky metal. The ohmic contact achieved a minimum contact resistivity of $5.51{\times}10.5{\Omega}{\cdot}cm^{2}$ after annealing in an $N_{2}$ ambient at $700^{\circ}C$ for 30 sec. The fabricated Schottky diode exhibited the barrier height of 0.7 eV and the ideality factor was 2.4, which are significantly lower than those parameters of crack free one. But in photoresponse measurement, the diode showed the peak responsivity of 0.097 A/W at 300 nm, the cutoff at 360 nm, and UV/visible rejection ratio of about $10^{2}$. The SPICE(Simulation Program with Integrated Circuit Emphasis) simulation with a proposed model, which was composed with one Pt/GaN diode and three parasitic diodes, showed good agreement with the experiment.

플라즈마 디스플레이 패널을 위한 $B_2O_3-Al_2O_3$-SrO계 유리의 물리적 특성 (Optical, Thermal and Dielectric Properties of $B_2O_3-Al_2O_3$-SrO Glasses for Plasma Display Panel)

  • 황성진;김진호;이상욱;김형순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.33-33
    • /
    • 2007
  • In PDP industry, the dielectrics and barrier ribs have been required with low dielectric constant, low melting point and Pb-free composition due to the low power consumption, low signal delay time and the environment restriction. We were studied with $B_2O_3-Al_2O_3$-SrO glass systems about optical, thermal and dielectric properties. The glass forming region of the $B_2O_3-Al_2O_3$-SrO glass systems was narrow due to the amount of the glass former $(B_2O_3)$. The glass transition temperature (Tg) of the glasses was at $550{\sim}590^{\circ}C$. The glasses have 6~8 for the dielectric constant. Furthermore, the transmittance of the glasses was over 80% on the range of the visible ray. From the results, the glasses of the $B_2O_3-Al_2O_3$-SrO glass systems should enable to be a good candidate of the PDP devices for information display with low dielectric constant. The aim of this study is to give a fundamental result of new glass system for low dielectric constant in the information display.

  • PDF

휠체어 사용자의 대변기 접근 방식 선호도 분석에 관한 연구 - 휠체어 사용자의 장애 유형 및 휠체어 종류를 중심으로 (A Study on Preference of Wheelchair Users to Toilet Approach Way - Focused on Wheelchair Users' Disability Types and Their Wheelchair Types)

  • 배융호;이경성
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.17-27
    • /
    • 2020
  • Purpose: The purpose of this study is to identify the difference in toilet approach way by wheelchair users according to the direction of the door and to suggest the layout of the toilet rooms most accessible to the wheelchair users. Methods: Survey to wheelchair users about approach to toilet have been conducted for the data collection. 90 answers have been analyzed statistically by SPSS 19.0 program. Results: The conclusions of this study are as follows. Firstly, spinal cord disorders prefer diagonal approach and lateral approach to the toilet, but brain lesions prefer diagonal approach and frontal approach to toilet. Secondly, the manual wheelchair users prefer the diagonal approach and the lateral approach to the toilet, and the electric wheelchair users has a different approach way to the toillet depending on the direction of the door. Finally, the layout of accessible toilets have to be designed for the diagonal approach to toilet, which is most preferred by wheelchair users. Implications: The toilet approach varies according to the disability types and the wheelchair types. Therefore, the size of accessible toilets should be larger than now considering the access of variety wheelchair users.

고분자 기판위에 유기 용매를 사용하지 않은 다층 박막 Encapsulation 기술 개발 (Improvement of Permeation of Solvent-free Multi-Layer Encapsulation of thin films on Ethylene Terephthalate(PET))

  • 강희진;한진우;김종연;문현찬;최성호;박광범;김태하;김휘운;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.56-57
    • /
    • 2006
  • In this paper, the inorganic multi-layer thin film encapsulation was newly adopted to protect the organic layer from moisture and oxygen. Using the electron beam, Sputter, inorganic multi-layer thin-film encapsulation was deposited onto the Ethylene Terephthalate(PET) and their interface properties between inorganic and organic layer were investigated. In this investigation, the SiON SiO2 and parylene layer showed the most suitable properties. Under these conditions, the WVTR for PET can be reduced from a level of $0.57\;g/m^2/day$ (bare subtrate) to 1*10-5 g/$m^2$/day after application of a SiON and SiO2 layer. These results indicates that the PET/SiO2/SiON/Parylene barrier coatings have high potential for flexible organic light-emitting diode(OLED) applications.

  • PDF

Poly(vinyl alcohol)/sulfo-succinic acid 이온교환막에 poly(acrylic acid)첨가에 따른 특성 연구 (The Effect of PAA on the Characterization of PVA/SSA ion Exchange Membranes)

  • 임지원;천세원;홍상혁;황호상;정성일
    • 멤브레인
    • /
    • 제13권2호
    • /
    • pp.118-124
    • /
    • 2003
  • 막소재는 투과증발 막공정에서 메탄을 저항체로 잘 알려진 Poly(vinyl alcohol, PVA)과 술폰기가 있는 가교제 sulfo-succinic acid(SSA)를 PVA에 대해 17 wt.%로 고정시켜 제조하였다. 이에 이온교환능력을 향상시키기 위해 양이온교환기가 포함된 poly(acrylic acid, PAA)를 첨가하여 함량변화에 따라 메탄올투과도 (methanol permeability) 특성과 이온전도도(ion conductivity)를 측정하였으며, 기본적인 이온교환막의 특성인 함수율 (water content), 이온교환용량 (ion exchange capacity, IEC) 등을 측정하였다. PAA함량에 따른 메탄을 투과도와 이온전도도 결과는 SSA만을 사용했을 때 보다 전체적으로 감소하는 경향을 나타났는데 이는 PAA의 함량 증가를 통하여 가교도의 증가로 인한 자유부피감소가 카르복실기인 양이온교환기 도입 영향보다 더 크게 작용한 것으로 판단된다 이온전도도와 메탄올투과도의 결과로부터 'vehicle mechanism'이 본 실험에서 제조된 PVA/SSA/PAA막에서 더 우세한 영향을 미쳤을 것이라 사료된다.

Impact of Online Learning in India: A Survey of University Students during the COVID-19 Crisis

  • Goswami, Manash Pratim;Thanvi, Jyoti;Padhi, Soubhagya Ranjan
    • Asian Journal for Public Opinion Research
    • /
    • 제9권4호
    • /
    • pp.331-351
    • /
    • 2021
  • The unprecedented situation of COVID-19 caused the government of India to instruct educational institutions to switch to an online mode to mitigate the losses for students due to the pandemic. The present study attempts to explore the impact of online learning introduced as a stop-gap arrangement during the pandemic in India. A survey was conducted (N=289), via Facebook and WhatsApp, June 1-15, 2020 to understand the accessibility and effectiveness of online learning and constraints that students of higher education across the country faced during the peak times of the pandemic. The analysis and interpretation of the data revealed that the students acclimatized in a short span of time to online learning, with only 33.21% saying they were not satisfied with the online learning mode. However, the sudden shift to online education has presented more challenges for the socially and economically marginalized groups, including Scheduled Caste (SC), Scheduled Tribes (ST), Other Backward Class (OBC), females, and students in rural areas, due to factors like the price of high-speed Internet (78.20% identified it as a barrier to online learning), insufficient infrastructure (23.52% needed to share their device frequently or very frequently), poor Internet connectivity, etc. According to 76.47% of respondents, the future of learning will be in "blended mode." A total of 88.92% of the respondents suggested that the government should provide high-quality video conferencing facilities free to students to mitigate the division created by online education in an already divided society.

Assessment of Universal Design for Seoullo 7017 in Seoul, Korea - Using a New Seven Universal Design Principles -

  • Yoo, Jieun;Kim, Jin-Oh
    • 휴양 및 경관연구
    • /
    • 제12권4호
    • /
    • pp.35-44
    • /
    • 2018
  • The purpose of this research is to evaluate Seoullo 7017 based on Universal Design (UD) principles and guidelines. To derive UD principles applicable to the site context, we used the 2017 Seoul Universal Design Guideline and assessment index provided by the Universal Design Research Center and established 11 evaluation criteria. With respect to research methods, a literature review and on-site field survey were applied, through which we derived UD principles and evaluation criteria to identify UD problems. The 11 evaluation criteria consist of pedestrian space, facilities, access, main entrance, parking lots, trails, restrooms, convenience facilities, information facilities, rest areas, and playgrounds, and these were associated with UD principles for evaluation. As a result, the main entrance had the highest UD score, while parking lots had the lowest in terms of equity, safety, simplicity, and accessibility. Restrooms received a lower UD score because of poor conditions of security and alert systems. Rest areas were found to be uncomfortable for disabled people. With respect to the internal trails, we found the lack of braille block and irregular placement of planting pots made blind people uncomfortable when walking. In terms of UD principles, flexibility received the highest score, followed by amenity, equity, simplicity, tolerance, accessibility, and safety. Flexibility received the highest score, owing to the provision of proper information about convenience facilities and trails, while safety received the lowest, based on poor access to parking lots, inadequate paving materials and colors, and a lack of 24-hour security systems. We hope this research contributes to improving the universal design, so that people are not discriminated against in the use of the park in terms of age, sex, or physical disability. We expect the study to help facilitate empirical studies to verify UD principles and provide improved quality of UD for Seoullo 7017.

휠체어사용자용 화장실의 규격기준에 대한 연구 (A Study on Standards of Wheelchair User Accessible Toilet Rooms)

  • 신동홍;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권4호
    • /
    • pp.27-35
    • /
    • 2018
  • Purpose: The diverse users and the increase of power wheelchair users have made it difficult to apply the standards of Wheelchair user accessible toilet rooms for the existing law and BF-certification. To address these issues, the standards of the relevant laws have been improved (Ministry of Health and Welfare, 2018), but there are still many problems. In this study, problems with the standards for Wheelchair user accessible toilet rooms in Korea are analyzed by comparing national and international standards. In addition, improvements to standards for Wheelchair user accessible toilet rooms will be suggested. Method: It presents improvement for standards of Wheelchair user accessible toilet rooms by comparing national, international standard and standards of many countries. Korean standard, International Standard(ISO 21542), American Standard(ADA Standards), German Standard(DIN 18040-1), Austrian Standard($\ddot{O}NORM$ B 1600) and Swiss Standard(Norm SIA 500) were investigated and analyzed. Results: Korea's standards differ from the ISO and the Standards of other countries in many ways, so there is a need for realignment. Specifications for disabled toilets and clear criteria for the size, shape, and location of sanitary appliances in toilets that are practically available to wheelchair users should be provided. Considering the increasing number of disabled toilet users, the installation of various disabled toilet rooms should be considered considering the user characteristics of those who can walk and wheelchair users. Implication: Recent partial improvements to relevant laws cannot meet the requirements of various users. Therefore, comprehensive and clear standard should be presented that take into account changing society and the environment.