Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors (실충격음과 표준충격원으로 발생된 바닥충격음의 비교)

  • Sato, Shin-Ichi;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

Evaluations on isolation method of floor impact sounds by real impact source (실충격원을 고려한 바닥충격음 저감방안의 평가)

  • Yoo, Seung-Yup;Lee, Pyung-Jik;Jeong, Young;Jeon, Jin-Yong;Ryu, Jong-Kwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.366-370
    • /
    • 2006
  • In this study, characteristics of impact force and impact sound of impact source such as bang machine, impact ball, and children's jumping were review. Results of review showed that impact ball has most similar characteristic to real impact sources in terms of objective properties such as impact force and impact sound. The effects of various isolator on floor impact sound were also investigated in apartment building and test facilities building using bang machine an impact ball. From the field measurement, it was found that the difference in reduction sound level between bang machine and impact ball was relatively large and the reduction sound level by impact ball was much larger than bang machine.

  • PDF

Psvchoacoustical Evaluation of Floor Impact Noise (바닥충격음의 심리음향학적 평가)

  • 전진용;정정호;조문재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.253-258
    • /
    • 2001
  • Floor impact noises in apartment buildings have been investigated as they are most annoying in living environment. Several experiments were undertaken to compare perceived noisiness of floor impact noises generated by bang and tapping machine along with children's jumping and running. Results show that bang noise is more annoying than tapping noise and floor impact noise generated by children is less annoying than the noise generated by machine. The floor impact noise generated by children's jumping and running corresponds well with the bang-machine noise in terms of loudness, unbiased annoyance, ${\Phi}$$\_$0/ and IACC. The noise generated by children is somewhat different from machine noise; in spatial impression the real noise is similar to tapping-machine noise but is less annoying that the machine noises.

  • PDF

A Study of the History of Korea DA-BANG Culture (한국 다방문화의 변천에 관한 연구)

  • 김석수
    • Korean Institute of Interior Design Journal
    • /
    • no.13
    • /
    • pp.37-44
    • /
    • 1997
  • The aim of this study is to find out the changes that have happened to korea DA-BANG(tea-room). This survey was carried out from 1876 to 1997 and the subject of this study is korea DA-BANGS in Seoul. Following conclusions were obtained from this study. 1) DA-BANG came into being from Koryo ages and more DA-BANGS from 1920's. 2) DA-BANG has changed in the following order : GAEWHA DA-BAHG(that were used to meet, communicate and negotiate foreigners when out country was opening ports), MUNWHA DA-BANG(that were used cultural space for example, exhibitio, display etc.), SEANGWHAL DA-BANG(the place that used a part of living space ; meeting friends to make appointment, etc.), SANGUB DA-BANG(commercial tea-room ; the place that makes money.) 3) Considering early MUNWHA DA-BANG, we can regard the beginning of korea interior architecture as 1920's. 4) The decline of DA-BANG is due to the increase of vending machine, expensive tea, costly rent, employee's dear wages and customer's needs that pursues westernization and convenient life as well as the moodof more comfortable tea-room(for example, fresh air, agreeable mood etc.).

  • PDF

Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data (공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교)

  • Yun, Chang-Yeon;Yeon, Jun-Oh;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis (시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

Development of multi crusher system using the principle of the Yeon-Ja-Bang-A (연자방아의 원리를 이용한 다기능 파쇄기 개발)

  • 조현철;천세영;안태규;양순용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.215-218
    • /
    • 2004
  • This paper is about a study of development on multi crusher system. This system use the principle of the Yeon-Ja-Bang-A. This system consists of the power part and the power transmit part, the Yeon-Ja Stone part, the crusher part, an input part, an output part. The advantage of this system decrease about working hours and installation aera.

  • PDF

Improvement on the estimation of workable-quantity per unit time for boring machine (기초공사 천공기계 시간당작업량 산정 개선방안)

  • Ahn, Bang-Ryul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.138-139
    • /
    • 2015
  • Human productivity of Boring Machine for stack is provided but not its hourly workable quantity(Q-value) in the Equipment ownership cost and expenses section of the Poom-Same that is used for construction cost estimation of public sectors in Korea, which leads to less realistic and subjective estimation for the works. The optimized Q-value of the machine is proposed as a result of thorough investigation into many of its operations.

  • PDF

Energy Saving Algorithms for Cooling Systems in Machine Tools (공작기계 냉각시스템의 에너지 절감 알고리즘)

  • Kim, Taejung;Kim, Taeho;Jee, Sungchul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Machine tools usually consume more energy in cooling systems than in spindle motors. This is largely because circulation pumps in the cooling systems are continuously powered to measure the temperature of spindle motors. In this paper, energy saving algorithms are proposed, which modify this behavior of the circulation pumps in such a way that the circulation pumps run only when it is likely that the information on the temperature is critical to bang-bang control of compressors in cooling systems. A mathematical model is established that explains heat transfer phenomena near the spindle motors. The power consumptions are measured for individual components in a machine tool, and the parameters that appear in the mathematical model are estimated. Computer simulations are performed with the estimated parameters, and the results are compared with the experimental ones. It turns out that a large amount of energy can be saved by using the proposed method.