• 제목/요약/키워드: band image

Search Result 997, Processing Time 0.027 seconds

Studies on the millimeter-wave Passive Imaging System III (밀리미터파 수동 이미정 시스템 연구 III)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.111-116
    • /
    • 2007
  • We have developed a passive millimeter wave (PMMW) imaging system with two-dimensional imaging arrays. For the imaging system we achieved single-substrate imaging-array element which include all necessary component such as Fermi tapered slot antenna (TSA), a balun, LNA's and a detector circuit on it. Two-dimensional arrays for real-time imaging at the 35 GHz band are currently under development. We will be able to make an advanced PMMW image system based on our system with the $2\times2$ imaging array in the near future.

An Experimental Study on the Spray Characteristics by Twin-Fluid Atomizer for Wide Band Spray (광폭면 분무를 위한 2유체 노즐의 분무 특성에 관한 연구)

  • Lee, Joong-Soon
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.212-219
    • /
    • 2008
  • To develop the twin-fluid atomizer having the excellent performance of painting, the spray characteristics of how a wide area can be painted efficiently by one time spraying were studied in this paper. Spray phenomena are affected by the many factors determining the spray field such as the spraying pressure of gas, the spraying pressure and viscosity of liquid paints, the opening duration of needle valve, the design dimension of nozzle, and so on. As the results of experiments, these factors affecting on spray characteristics were suggested as followings; 1) The optimum spraying pressure of gas was $0.015{\sim}0.02\;kPa$, and the appropriate spraying pressure of liquid paint was 0.01kPa, In these situations, the setting up pressures must be compensated as much as the losing amount of pressure because a decompression occurred when operating valves. 2) The duration of opening the needle valve must be sustained for $1{\sim}2$ seconds to inject gas after spraying the liquid paint. This operating of the needle valve was necessary to avoid the affect on the changing of liquid column length, and to prevent the droplet deposit at the initial time of spraying. 3) The spray tip penetration was gained form the experimental equation, and the effective spraying angle was $85^{\circ}{\pm}5^{\circ}$ just at he appropriate spraying pressure of gas. The distribution of the area sprayed had the variation in $350{\pm}50\;mm$ because of the spraying pressure of gas, the its distance from the spray tip, and the lift of the needle valve.

  • PDF

Photoelectrochemical Cell Study on Closely Arranged Vertical Nanorod Bundles of CdSe and Zn doped CdSe Films

  • Soundararajan, D.;Yoon, J.K.;Kwon, J.S.;Kim, Y.I.;Kim, S.H.;Park, J.H.;Kim, Y.J.;Park, D.Y.;Kim, B.C.;Wallac, G.G.;Ko, J.M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2185-2189
    • /
    • 2010
  • Closely arranged CdSe and Zn doped CdSe vertical nanorod bundles were grown directly on FTO coated glass by using electrodeposition method. Structural analysis by XRD showed the hexagonal phase without any precipitates related to Zn. FE-SEM image showed end capped vertically aligned nanorods arranged closely. From the UV-vis transmittance spectra, band gap energy was found to vary between 1.94 and 1.98 eV due to the incorporation of Zn. Solar cell parameters were obtained by assembling photoelectrochemical cells using CdSe and CdSe:Zn photoanodes, Pt cathode and polysulfide (1M $Na_2S$ + 1M S + 1M NaOH) electrolyte. The efficiency was found to increase from 0.16 to 0.22 upon Zn doping. Electrochemical impedance spectra (EIS) indicate that the charge-transfer resistance on the FTO/CdSe/polysulfide interface was greater than on FTO/CdSe:Zn/polysulfide. Cyclic voltammetry results also indicate that the FTO/CdSe:Zn/polysulfide showed higher activity towards polysulfide redox reaction than that of FTO/CdSe/polysulfide.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Intra-night optical variability of AGN in COSMOS field

  • Kim, Joonho;Karouzos, Marios;Im, Myungshin;Kim, Dohyeong;Jun, Hyunsung;Lee, Joon Hyeop;Pallerola, Mar Mezcua
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.64.2-64.2
    • /
    • 2016
  • Optical variability is one way to probe the nature of the central engine of AGN at smaller linear scales and previous studies have shown that optical variability is more prevalent at longer timescales and at shorter wavelengths. Especially, intra-night variability can be explained through the damped random walk model but small samples and inhomogeneous data have made constraining this model hard. To understand the properties and physical mechanism of optical variability, we are performing the KMTNet Active Nuclei Variability Survey (KANVaS). Test data of KMTNet in the COSMOS field was obtained over 2 separate nights during 2015, in B, V, R, and I bands. Each night was composed of 5 and 9 epochs with ~30 min cadence. To find AGN in the COSMOS field, we applied multi-wavelength selection methods. Different selection methods means we are looking different region in unification model of AGN, and 100~120, 400~500, 50~100 number of AGN are detected in X-ray, mid-infrared, and radio selection of AGN, respectively. We performed image convolution to reflect seeing fluctuation, then differential photometry between the selected AGN and nearby stars to achieve photometric uncertainty ~0.01mag. We employed one of the standard time-series analysis tools to identify variable AGN, chi-square test. Preliminarily results indicate that intra-night variability is found for X-ray selected, Type1 AGN are 23.6%, 26.4%, 21.3% and 20.7% in the B, V, R, and I band, respectively. The majority of the identified variable AGN are classified as Type 1 AGN, with only a handful of Type 2 AGN showing evidence for variability. The work done so far confirms that there are type and wavelength dependence of intra-night optical variability of AGN.

  • PDF

Coast Evaluation Techniques for Mode Selection in Video Coding (동영상에서 모드 선택을 위한 코스트 평가 방법)

  • Song, Dae-Geon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.275-280
    • /
    • 2013
  • Recently, access networking BroadBand the high performance of the video equipment to the Internet via voice, video, multimedia services, such as dealing with the media information dissemination is becoming increasingly attracting attention. More video devices and network environments in the future to keep pace with the high-quality video using the form dealing with an increasingly diversified and shall utilization is expected. Among them, video encoding technology, image compression encoding technology of information technology is one of the central role. Video coding technology that requires a vast amount of information contained in the video signal and the appropriate amount of information to eliminate redundancy as the efficiency of the digital code representing video signal is developed as a technology is going. Therefore, this study applied to video coding mode selection in the cost evaluation methods to examine and to maximize the coding efficiency and the proposed method compared to the conventional method was confirmed excellence.

COMPONENT-BASED DEVELOPMENT OF OBSERVATIONAL SOFTWARE FOR KASI SOLAR IMAGING SPECTROGRAPH

  • Choi, Seong-Hwan;Kim, Yeon-Han;Moon, Yong-Jae;Choi, Kyung-Seok;Park, Young-Deuk;Jang, Bi-Ho;Kim, Su-Jin;Kim, Kap-Sung
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.4
    • /
    • pp.463-470
    • /
    • 2005
  • In this paper, we have made the component-based development of observational software for KASI solar imaging spectrograph (KSIS) that is able to obtain three-dimensional imaging spectrograms by using a scanning mirror in front of the spectrograph slit. Since 2002, the KASI solar spectrograph has been successfully operated to observe solar spectra for a given slit region as well as to inspect the response functions of narrow band filters. To improve its capability, we have developed the KSIS that can perform sequential observations of solar spectra by simultaneously controlling the scanning mirror and the CCD camera via Visual C++. Main task of this paper is to introduce the development of the component-based software for KSIS. Each component of the software is reusable on the level of executable file instead of source code because the software was developed by using CBD (component-based development) methodology. The main advantage of such a component-based software is that key components such as image processing component and display component can be applied to other similar observational software without any modifications. Using this software, we have successfully obtained solar imaging spectra of an active region (AR 10708) including a small sunspot. Finally, we present solar $H{\alpha}$ spectra ($6562.81{\AA}$) that were obtained at an active region and a quiet region in order to confirm the validity of the developed KSIS and its software.

A Study on Extracting the Landuse Change Information of Seoul Using LANDSAT(MSS, TM) Data (1972~1985) (LANDAST(MSS, TM) Data를 이용(利用)한 서울시(市)의 토지이용(土地利用) 경년변화(經年變化)의 추출(抽出)에 관한 연구(硏究) (1972~1985년))

  • Ahn, Chul Ho;Ahn, Ki Won;Kim, Yong Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.4
    • /
    • pp.113-124
    • /
    • 1989
  • In this study, we tried to extract the land-use change information of Seoul city using the multiple date images of the same geographic area. Multiple date image set is MSS('72, '79, '81, '93) and TM('85), and we carried out geometric correction, digitizing(due to the administrative boundary) in pre-processing process. In addition, we performed land-use classification with MLC(Maximum Likelihood Classifier) after improving the predictive accuracy of classification by filtering technique. At the stage of classification, ground truth data, topographic maps, aerial photographs were used to select the training field and statistical data of that time were compared with the classification result to prove the accuracy. As a result, urban area in Seoul has been increased('72 : 25.8 %${\rightarrow}$'81 : 43.0 %${\rightarrow}$'85 : 51.9 %) and Forest area decreased ('72 : 39.0 %${\rightarrow}$'85 : 28.4 %) as we estimated. Finally, it is concluded that the utilzation of satellite imagery is very effective, economical and helpful in the urban land-use/land-cover monitoring.

  • PDF

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

The Method of Reducing Echo Time in 3D Time-of-flight Angiography

  • Park, Sung-Hong;Park, Jung-Il;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.367-369
    • /
    • 2002
  • We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.

  • PDF