• 제목/요약/키워드: balancing control

검색결과 637건 처리시간 0.026초

시각적 Target 프로그램이 균형에 미치는 영향 (The Effects of Visual Target Program on Balance)

  • 최재청;지중구;박정서;한슬기
    • 대한물리치료과학회지
    • /
    • 제17권1_2호
    • /
    • pp.33-39
    • /
    • 2010
  • Purpose: The purpose of this study was to analyze the effects of a balance training program using the TARGET Balance Trainer(TBT), which utilizes a visual target, on the balancing ability of normal, healthy individuals. Methods: Twelve healthy female students with an average of 20.7 years(SD=0.25), were participated in this study. They were randomly divided into two groups(6 subjects in each group); experimental group, control group. The experimental group underwent a 3-week training program using the TBT, while the control group trained using only a dynamic air cushion(DAC). Results: Compared to those who trained using only the DAC, participants who trained with the TBT had a smaller difference between the weights distributed(N) to their left and right foot while normal standing with their eyes open. The TBT group also showed a smaller discrepancy between the weights distributed(N) to their left and right sides while standing on one leg with their eyes open, and also with their eyes closed by eye band. Conclusions: TBT is effective to reduce the degree of weight shifting between left and right side in each group. This study is expected to provide a model for future clinical studies.

  • PDF

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

품질개선 및 혁신활동에서 재무성과 측정모형의 개발 (Development of Financial Effect Measurement(FEM) Models for Quality Improvement and Innovation Activity)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.337-348
    • /
    • 2015
  • This research introduces the Financial Effect Measurement (FEM) models which measures both the improvement and the innovation performance of Quality Control Circle (QCC) and activities of Six Sigma. Concepts and principle of Comprehensive Income Statement (CIS), Balanced Scorecard (BSC), Time-Driven Activity Based-Costing (TDABC) and Total Productive Maintenance (TPM) are applied in order to develop the 4 FEM models presented in this paper. First of all, FEM using CIS depicts the improvement effects of production capacity and yield using relationships between demand and supply, and line balancing efficiency between bottleneck process and non-bottleneck processes. Secondly, cause-and-effect relation of Key Performance Indicator (KPI) is used to present Critical Success Factor (CSF) effects for QC Story 15 steps of QCC and DMAIC (Define, Measure, Analyze, Improve, and Control) of Six Sigma. The next is FEM model for service management innovation activities that uses TDABC to calculate the time-driven effect for improving the indirect activities according to the cost object. Lastly, FEM model for TPM activities presents the interpretation of improvement effect model of TPM Capital Expenditure (CAPEX) and Operating Expenditure (OPEX) maintenance using profit, cash and Economic Added Value (EVA) as metrics of enterprise values. To better understand and further investigate FEMs, recent cases on National Quality Circle Contest are used to evaluate new financial effect measurement developed in this paper.

Software of Slit-Viewing Camera Module for IGRINS (Immersion GRating INfrared Spectrograph)

  • Lee, Hye-In;Pak, Soojong;Lee, Jae-Joon;Mace, Gregory;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.66.1-66.1
    • /
    • 2016
  • We developed an observation control software for the IGRINS (Immersion Grating Infrared Spectrograph) silt-viewing camera module, which points the astronomical target onto the spectroscopy slit and sends tracking feedbacks to the telescope control system. The point spread function (PSF) is not always symmetric. In addition, bright targets are easily saturated and shown as a donut shape. It is not trivial to define and find the center of the asymmetric PSF especially on a slit mask. We made a center balancing algorithm (CBA) following the concept of median. The CBA derives the expected center position along the slit-width axis by referencing the stray flux ratios of both upper and lower sides of the slit. We compared efficiencies of the CBA and those of a two-dimensional Gaussian fitting (2DGA) through simulations from observation images in order to evaluate the center finding algorithms. Both of the algorithms are now applied in observation and users can select the algorithm.

  • PDF

한 발 뜀뛰기 모델을 이용한 사실적인 달리기 애니메이션 (A Realistic Running Animation with One-Legged Hopper Model)

  • 강영민;박선진;조환규
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제4권2호
    • /
    • pp.1-13
    • /
    • 1998
  • 캐릭터 애니메이션의 가장 중요한 목표는 효율적으로 캐릭터의 동작을 제어하는 것이다. 지금까지 인간 보행 애니메이션을 위한 많은 기법들이 제안되었고, 파라미터 보간이나 동작 데이터 매핑 을 사용하여 지친 걸음이나 활기찬 걸음과 같은 보행의 감정을 표현하는 기법도 제안되었다. 본 논문은 하나의 다리를 가진 평면 뜀뛰기 모델에 기반한 인간 주행 모델을 제시한다. 본 논문의 기법은 동작 최적화를 위해 유전자 프로그래밍을 사용하며 다양한 캐릭터 모델에 쉽게 적용될 수 있다. 본 논문은 에너지 최소화 기법을 확장하여 감정 표현을 위한 파라미터 설정에 따라 다양한 동작을 생성할 수 있도록 한다.

  • PDF

The Effect of a Balance Training Program to Improve the Balance of Aged Patients with Diabetes Mellitus

  • Lee, Yong-Woo;Choi, Se-Jong;Song, Chang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • 제22권3호
    • /
    • pp.23-30
    • /
    • 2010
  • Purpose: The purpose of this study was to determine whether a balance training program could improve the balancing ability of elderly patients with type II diabetes mellitus. If yes, the results could lead to development of a method to prevent falls in elderly patients with type II diabetes mellitus (DM). Methods: Subjects were 28 elderly patients with type II DM. Subjects were divided into a control and an experimental group with 14 patients in each group. The experimental group had a balance training program consisting of balance training and lower extremity muscle strengthening exercises. The exercise group met twice a week for 8 weeks. All subjects were evaluated using a force plate for the amount of postural sway. To determine the degree of diabetes, we measured Hemoglobin A1c. Results: Balance in the experimental group (p<0.05) increased significantly compared to the control group. Conclusion: The results suggest that a balance training program should be recommended for improving balance and preventing falls in elderly type II DM patients.

SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발 (Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring)

  • 하복남;이성우;신창훈;서인용;장문종;박민호;윤기갑;송일근;이병성;이정철;남궁원
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

Neutral-Point-Clamped 인버터의 저 변조지수에서 DC 링크 전압 균형을 위한 간단한 컨트롤 기법 (A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverters at low modulation index)

  • 마창수;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.560-564
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM(DPWM) to balance the DC-link voltage of three-level Neutral-Point-Clamped(WPC) inverters at low modulation index. New DPWM methods in multi-level inverter are also introduced. The proposed DPWM method changes the path and duration to flow the neutral point current out of or into neutral point of the DC-link and it makes the overall fluctuation of the DC-link voltage zero during a sampling time of reference voltage vector. Therefore, the voltage of the DC-link can be balanced fairly well and also the voltage ripple of the DC-link is reduced significantly. Moreover, comparing with conventional methods, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by experiment

  • PDF

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

Dinamika를 이용한 중풍환자의 자율신경계 활성도에 대한 연구 (Study on Activity of Autonomic Nerve System Using Dinamika on Stroke)

  • 이성도;전종철;박동일
    • 동의생리병리학회지
    • /
    • 제19권4호
    • /
    • pp.1088-1091
    • /
    • 2005
  • This study was designed to research whether Dinamika can yield a suitable diagnosis for Activity of Autonomic Nene System on stroke. The testing of Dinamika was carried out at Oriental Medical Centar of Dong-Eui University with the participation of 27 patients. The results of Dinamika examinations shows as follows : Group A(the rising of a parasympathetic nerve system) is 0 persons. And Group B(the balancing autonomic none system) is 4 persons. Group C(the rising of a sympathetic nerve system) is 23 persons. There are 7 persons that it is difference of more than $20\%$ between B1 (the control ability of autonomic nerve system) and B2(the potential energy to control autonomic nerve system), 11 person that B1 and B2 are less than $10\%$, 1 person that B1 and B2 are balanced about $60\%$, 8 person that it is balanced domain from $10\%\;to\; 60\%$ between B1 and B2. According to this study on activity of autonomic nerve system using Dinamika on Stroke, these results suggest that 27 patients evidence the problem of autonomic none systems.