• Title/Summary/Keyword: axial tension

Search Result 302, Processing Time 0.031 seconds

Finite Element Analysis and Fatigue Life Evaluation of Automotive Rubber Insulator (자동차 방진 고무 부품의 유한요소해석 및 피로수명평가)

  • Kim, W.D.;Woo, C.S.;Han, S.W.
    • Elastomers and Composites
    • /
    • v.33 no.3
    • /
    • pp.168-176
    • /
    • 1998
  • A strut rubber insulator is used in a suspension component of passenger cars. The uni-axial tension, compression, and the shear test were performed to acquire the constants of the strain energy functions which were Mooney-Rivlin model and Ogden model. The finite element analysis was executed to evaluate the behavior of deformation and stress distribution by using the commercial finite element code MARC ver K6.2. Also, the fatigue tests were carried out to obtain the fatigue life-load curve. The fatigue failure was initiated at the folded position of rubber, which was the same result predicted by the finite element analysis.

  • PDF

Low Cycle Fatigue Behavior of Longitudinal Reinforcement (축방향철근의 저주파 피로 거동)

  • Lee, Jae-Hoon;Ko, Seong-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.263-271
    • /
    • 2010
  • The purposes of this study is to verify the fracture characteristic of steel which is manufactured in Korea, subjected to cyclic loading. This investigation deals with the low cycle fatigue behavior of longitudinal reinforcement in reinforced concrete bridge substructure (piles and columns of piers). Eighty-one specimens of longitudinal reinforcement were tested under axial strain controlled reversed cyclic tests with strain amplitudes. The selected test variables are ratio of tension strain to compression strain, yield stress of longitudinal reinforcement, ratio of diameter of longitudinal steel to clear length of longitudinal steel, size of longitudinal steel and strain amplitudes. Low cycle fatigue behavior and low-cycle fatigue life are investigated and discussed in this paper.

An evaluation of compressive lap splice of the D22 rebar by concrete strengths (콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가)

  • Lee, Sung-Ho;Chun, Sung-Chul;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1081-1084
    • /
    • 2008
  • Column specimens were constructed with main parameters significantly affecting the strength of the compression lap splice, such as lap length, spacing of lapped bars, amount and location of transverse reinforcements, and concrete strength. An experimental study has been conducted with column specimens in concrete strength of 40 to 60 MPa. Diameters of lapped reinforcing bars are 22 mm. An axial load was monotonically applied to the column specimens. All specimens failed in a brittle sudden manner and cover concrete was blasted out at maximum load. Compression lap splice strengths of specimens were evaluated from strains measured at the beginning of the lap length. Effects of the main parameters on the strengths of compression lap splice are assessed. Similarly to strengths of tension lap slice, the compression splice strength is found to be affected by lap length, spacing of lapped bars, transverse reinforcements.

  • PDF

Plastic Limit Load Solutions for Circumferential Surface Cracked Cylinders Under Combined Loading (복합하중이 작용하는 원주방향 표면균열배관에 대한 소성한계하중식)

  • Shim, Do-Jun;Kim, Yun-Jae;Kim, Young-Jin;Hwang, Seong-Sik;Kim, Joung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1469-1476
    • /
    • 2003
  • This paper provides plastic limit load solutions of cylinders with circumferential part-through surface cracks under combined axial tension, internal pressure and global bending. Such solutions are developed based on detailed three-dimensional (3-D) finite element (FE) limit analyses using elastic-perfectly-plastic material behaviour, together with analytical solutions based on equilibrium stress fields. For the crack location, both external and internal cracks are considered. Furthermore, in terms of the crack shape, both semi-elliptical and constant-depth surface cracks are considered. The resulting limit load solutions are given in a closed form, and thus can be easily used in practical situations. Being based on detailed 3-D FE limit analysis, the present solutions are believed to most reliable, and thus to be valuable information for integrity assessment of piping.

The Absorbed Energy Characteristics of Gr/E Composite Tubes under Axial Collapse Load (축 압궤하중을 받는 Gr/E 복합재 튜브의 에너지 흡수특성)

  • 양현수;김영남;최흥환
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.2
    • /
    • pp.189-197
    • /
    • 2002
  • Composites have wide applications in aerospace vehicles and automobiles because of the inherent flexibility in their design lot improved material properties. Composite tubes in particular, are potential candidates for their use as energy absorbing elements in crashworthiness applications due to their high specific energy absorbing capacity and the stroke efficiency. Their failure mechanism however is highly complicated and rather difficult to analyze. This includes fracture in fibers, in the matrix and in the fiber-matrix interface in tension, compression and shear. The purpose of this study is to investigate the energy absorption characteristics of Gr/E(Graphite/Epoxy) tubes on static and impact tests. The collapse characteristics and energy absorption of a variety of tubes have been examined. Changes in the lay-up which increased the modulus increased the energy absorption of the tubes. Based on the test results, the following remarks can be made: Among CA15, CA00 and CA90 curves the CA90 tube exhibits the highest crush load throughout the whole crush process, and max load increases as interlaminar number increase. Among all the tubes type CC90 has the largest specific crushing stress of 52.60 kJ/kg which is much larger than other tubes.

Arthrokinetic Analysis of Knee Joint (슬관절의 운동학적 분석)

  • Kim, Jae-hun
    • PNF and Movement
    • /
    • v.6 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • Purpose : To describes the important aspects of knee joint movement and function used when applying PNF technique to the lower limb. Method : The knee was a very important roles in the lower limb movement and ambulation. This study summarizes the physiologic movement of knee to the PNF lower extremity patterns. Result : The tibiofemoral joint is usually described as a modified hinge joint with flexion-extension and axial rotation by two degrees of freedom movement. These arthrokinematics are a result of the geometry of the joints and the tension produced in the ligamentous structures. The patellofemoral joint is a sellar joint between the patella and the femur. Stability of the patellofemoral joint is dependent on the passive and dynamic restraints around the knee. In a normal knee the ligaments are inelastic and maintain a constant length as the knee flexes and extends, helping to control rolling, gliding and translation of the joint motions. Conclusions : It is important to remember that small alterations in joint alignment can result in significant alterations in patellofemoral joint stresses and that changes in the mechanics of the patellofemoral joint can also result in changes in the tibiofemoral compartments. Successful treatment requires the physical therapist to understand and apply these arthrokinematic concepts. When applied to PNF low extremity patterns, understanding of these mechanical concepts can maximize patient function while minimizing the risk for further symptoms or injury.

  • PDF

Fabrication of an On System based on an Optical Delay line with Cylindrical PZT (실린더형 압전소자 광지연선을 이용한 광 간섭형 단층촬영(OCT) 시스템 제작)

  • Park, Sung-Jin;Kim, Young-Kwan;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • We demonstrate a compact optical coherence tomography(OCT) system based on the optical fiber delay line controlled by a cylindrical piezo-electric transducer(PZT). An 18-m length of single mode fiber is wrapped under constant tension around a PZT. Approximately 134 windings are used. Wraps of the long length of fiber allow the small expansion of the PZT to be magnified to an optical path length delay of 0.78 m. The OCT system shows characteristics for 2-dimensional imaging, exhibiting 96.9dB of signal-to-noise ratio(SNR), $18.6{\pm}0.5\;{\mu}m$ of axial resolution, and $5\;{\mu}m$ of lateral resolution with samples.

Crack Opening Area Assessment of Circumferential Though Wall Crack in a Pipe Subjected to Tension and Bending (인장과 굽힘을 받는 배관의 원주방향 관통균열 개구면적 평가)

  • Kim, Sang-Cheol;Kim, Maan-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.61-66
    • /
    • 2008
  • It is important to calculate the exact crack opening area in the cracked pipe subjected to axial force and bending moment. Among many solutions for obtaining the crack opening displacement, Paris-Tada's expression, which is derived from energy method, is open used in fracture analysis for piping crack problems because of its simplicity. But Paris-Tada's equation has conservativeness when radius over thickness ratio(R/t) is ten or less, for it is based on the stress intensity factor solution having a compliance function derived from a simple shell theory. In this paper we derived a new expression using a different stress intensity factor solution which is able to consider the variation of compliance through wall thickness in a cracked pipe. Conservativeness of both equations was examined and compared to finite element analysis results. Conservativeness of the new equation is decreased when R/t > 10 and increased slightly when R/t < 10 compared with Paris-Tada's. But Both equations were highly conservative when R/t < 10 compared with finite element analysis results.

Surgical Treatment of Adenoid Cystic Carcinoma by Left Tracheal Sleeve Pneumonectomy (좌측 수상 전폐 적출술에 의한 선양 낭포암 치험 1례)

  • 김동원
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.413-417
    • /
    • 1994
  • Adenoid cystic carcinoma usually grows in the trachea or near its bifurcation and causes obstruction of the air way. We recently experienced a 33 year-old male patient who had adenoid cystic carcinoma in the left main bronchus with the chief complaint of productive cough. On the bronchoscopy, the mass obstructed the left main bronchus completely and had nodularity and increased vascularity.The trachea was shifted to the left side and the lower lobe of the left lung was atelectatic on chest X-ray and computed axial tomogram.He underwent left tracheal sleeve pneumonectomy and lymph node dissection through bilateral thoracotomy. At first,we attempted left tracheal sleeve pneumonectomy through the left thoracotomy,however, it was very difficult to perform carinoplastic procedure after sleeve resection of 2.5cm of distal trachea and 1cm of proximal right main bronchus including whole left lung because of poor operative field and difficulty in the anastomosis of the right main bronchus to the distal end of the trachea without tension.Therefore after radical resection of the left lung we made right thoracotomy,through which we could anastomosed the distal trachea and right main bronchus with 4-0 PDS interrupted suture after mobilization of the right hilum without difficulty. The tumor was confirmed to be adenoid cystic carcinoma with metastasis to subcarinal lymph node histopathologically. Postoperative course was uneventful but he needed two bronchoscopic procedure to clear distal airway of the retained bronchial secretion. He was discharged at 14 days after operation with complete recovery.

  • PDF

Failure Prediction for an AZ31 Alloy Sheet during Warm Drawing using FEM Combined with Ductile Fracture Criteria (유한요소법과 연성파괴이론에 의한 AZ31합금 판재의 온간 드로잉 공정에서의 파단예측)

  • Kim, S.W.;Lee, Y.S.
    • Transactions of Materials Processing
    • /
    • v.21 no.4
    • /
    • pp.258-264
    • /
    • 2012
  • The forming failure of AZ31 alloy sheet during deep drawing processes was predicted by the FEM and ductile fracture criteria. Uniaxial tensile tests of round-notched specimens and FE simulations were performed to calculate the critical damage values for three ductile fracture criteria. The critical damage values for each criterion were expressed as a function of strain rate at various temperatures. In order to determine the best criterion for failure prediction, Erichsen cupping test under isothermal conditions at $250^{\circ}C$ were conducted. Based on the plastic deformation histories obtained from the FE analysis of the Erichsen cupping tests and the critical damage value curves, the initiation time and location of fracture were predicted under bi-axial tension deformation. The results indicate that the Cockcroft-Latham criterion had good agreement with the experimental data. In addition, the FE analysis combined with the criterion was applied to another deep drawing process using an irregular shaped blank and these additional results were verified with experimental tests.