• 제목/요약/키워드: average separation

검색결과 452건 처리시간 0.021초

비정상 후류가 난류박리기포의 응집구조에 미치는 영향 (Large-Scale Vortical Structure of Turbulent Separation Bubble Affected by Unsteady Wake)

  • 전세종;성형진
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1218-1225
    • /
    • 2002
  • Large-scale vortical structure of a turbulent separation bubble affected by unsteady wake is essential to understand flow mechanisms in various fluid devices. A spoked-wheel type of wake generator provides unsteady wake, which modifies the turbulent separation bubble significantly by changing rotation directions and passing frequencies. A detailed mechanism of vortex shedding from the separation bubble with unsteady wake is analyzed by taking a conditional average with spatial box filtering, which spatially integrates measured signals at pre-determined wavelength. A convecting nature of the large-scale vortical structure is analyzed carefully. Spatial evolution of the large-scale vortical structure with frequency variance is also exemplified.

Utilization of functionalized magnetic nanoparticles for high throughput DNA separation

  • 장정호
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.12.2-12.2
    • /
    • 2009
  • The work describes anoptimized process to highly efficient and convenient preparation in highthroughput magnetic human DNA separation with chemically functionalizedsilica-coated magnetic nanoparticles. The effect of nanoparticle's size and the surface's hydrophilicity change were studied for magnetic DNA separation process, inwhich the optimum efficiency was explored via the function of the amino-groupnumbers, particle size, the amount of the nanoparticles used, and theconcentration of NaCl salt. The DNA adsorption yields were high in terms of theamount of triamino-functionalized nanoparticles used, and the average particlesize was 25 nm. The adsorption efficiency of aminofunctionalized nanoparticleswas the 4-5 times (80-100%) higher compared to silica-coated nanoparticles only(10-20%). DNA desorption efficiency showed an optimum level of over 0.7 M ofthe NaCl concentration. To elucidate the agglomeration of nanoparticles afterelectrostatic interaction, the Guinier plots were calculated from small angleX-ray diffractions in a comparison of the results of electron diffraction TEM,and confocal laser scanning microscopy. Additionally, the direct separation ofhuman genomic DNA was achieved from human saliva and whole blood with highefficiency.

  • PDF

외식산업 조리종사자의 직무만족과 이직성향에 대한 실태분석 (The Condition Analysis about Job Satisfaction and Separation Propensity of Foodservice Industry Culinary Employee′s)

  • 이선호;김선희;김민수
    • 한국조리학회지
    • /
    • 제9권4호
    • /
    • pp.37-53
    • /
    • 2003
  • The purpose of this study was to find out efficient control plan for productivity increase. To analyze the data, the measure of question a paper was used to 5 a point measure, statistics disposition was used to SPSS, the analyze method was used to frequency analyze, trust degree analyze, difference analyze useful average value, person's correlation analyze, revolution analyze. The results of this study could be explained as follow: First, find out high change separation propensity. Secondly, was subjected important for atmosphere composition and was required strategy consideration for stable job recognition. Third, was operated affirmative to recognition about separation and was increased to job satisfaction according as a colleague relation and team work. Fourth, was increased to comparative separation propensity in case that high job satisfaction. Therefore it is required interesting labor item and treatment development about personal evaluation.

  • PDF

PC 방 금연구역의 간접흡연 노출 (Secondhand Smoke Exposure in Commercial Personal Computer Rooms)

  • 손홍지;오애리;김옥금;이기영
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.288-293
    • /
    • 2010
  • In this study, exposure to secondhand smoke (SHS) was evaluated in commercial personal computer (PC) rooms with different separation types of non-smoking areas. The particulate matter less than 2.5 ${\mu}m$ ($PM_{2.5}$) level was simultaneously measured by aerosol spectrometers in the non-smoking and smoking areas of these commercial PC rooms. Average $PM_{2.5}$ concentrations in non-smoking and smoking areas were $75\;{\mu}g/m^3$ and $136\;{\mu}g/m^3$, respectively. Although the $PM_{2.5}$ concentrations in non-smoking areas were significantly less than those in smoking areas (p<0.01), the levels still exceeded the US National Ambient Air Quality Standard of $35\;{\mu}g/m^3$. Average $PM_{2.5}$ concentrations in non-smoking areas were not significantly different with regard to area separation type, with $73\;{\mu}g/m^3$ in the no-wall type, $83\;{\mu}g/m^3$ in the wall-type, and $39\;{\mu}g/m^3$ in the separated-floor-type areas (p>0.1). Separation of the non-smoking area thus did not eliminate SHS exposure in commercial PC rooms, regardless of the type of area separation. This study demonstrates that simple separation of non-smoking areas in commercial PC rooms does not protect users from SHS.

흡착재에 의한 유출기름 회수용 유수분리의 가능성 연구 (A Study on Feasibility of Oil Separation with Oil Absorbent for Spilt Oil Recovery)

  • 박외철;권병곤
    • 한국안전학회지
    • /
    • 제13권2호
    • /
    • pp.39-44
    • /
    • 1998
  • An experimental study on oil absorbent was conducted to investigate the feasibility of utilizing absorbents in oil separation from water-oil mixture for spilt oil recovery. Experiments included investigations of absorptivity and filtering performance of a commercial oil absorbent for different diesel oil concentrations. The measured average absorptivity of the absorbent was above 92% for oil concentrations, 5, 10, 15vo1%, that shows good absorbing performance. Filtering the oil-water mixture, however, was too slow to be used for oil separation. An absorbent baffle system was suggested for oil separation which collects oil panicles by increasing contact between the absorbent and oil particles.

  • PDF

전기투석에 의한 유기산 혼합물로부터 숙신산의 분리 (Separation of Succinic Acid from Organic Acid Mixture Using Electrodialysis)

  • 김상헌;이병철
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.266-271
    • /
    • 2005
  • 혼합유기산으로부터 숙신산의 분리를 단극 분리막을 사용한 탈염전기투석장치를 이용하여 행하였다. 전류효율, 회수율, 에너지소요량, 분리비 등의 변화를 pH 값과 초기농도비에 따라 측정하였다. 숙신산의 분리는 숙신산과 아세트산의 이온화율, 분자량, 이온전도도, 전자가 크기 그리고 초기농도비 등으로 해석될 수 있었다.

Electrostatic Charging Measurement and PVC Separation of Triboeletrostatically Charged Plastic Particles using a Fluidized Bed Tribocharger

  • Shin, Jin-Hyouk;Lee, Jae-Keun
    • 한국분무공학회지
    • /
    • 제7권2호
    • /
    • pp.7-15
    • /
    • 2002
  • A particle flow visualization, electrostatic charging measurement and separation of triboelectrically charged particles in the external electric field by a fluidized bed tribocharger are conducted for the removal of PVC particles from mixed waste plastics. The laboratory-scale triboelectrostatic separation system consists of the fluidized bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PET particles can be imparted negative and positive surface charges respectively due to the difference of triboelectric charging series between particles and particles in the fluidized bed tribocharger, and can be separated by passing them through an external electric field. To visualize these charged particles, He-Ne laser is used with cylindrical lenses to generate a sheet beam. In the charging measurement, the particle motion analysis system (PMAS), capable of determining particle velocity and diameter. is used to non-intrusively measure particle behavior in high strength electric field. The average charge-to-mass ratios of PVC and PET particles are $1.4\;and\;1.2{\mu}C/kg$, respectively. The highly concentrated PVC (91.9%) can be recovered with a yield of about 96.1% from the mixture of PVC and PET materials for a single-stage processing. The triboelectrostatic separation system using the fluidized tribocharger shows the potential to be an effective method for removing PVC from mixed plastics for waste plastic recycling.

  • PDF

Field performance analysis of a card cleaner type separating system for a self-propelled pepper harvester

  • Shin, Seo-Yong;Cho, Yongjin;Kim, Su-Bin;Kim, Dae-Cheol
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.921-931
    • /
    • 2020
  • This study was carried out to determine the factor of a separating system according to the pepper varieties and the absence of a card cleaner system. The pepper varieties of Jeokyoung and AR-Legend were transplanted on November 20, 2019 and tested on March 18, 2020 with a harvesting speed of 0.2 m·s-1 for 10 pepper plants. The performance evaluation was determined by analyzing the separation efficiency of the peppers and the foreign matter mixing rate. The pepper harvester with a card cleaner showed a higher separation efficiency of the peppers compared to the pepper harvester without a card cleaner. The average separation efficiency of peppers on the pepper harvester with a card cleaner was higher at 13.5% for Jeokyoung and 1.9% for AR-Legend than that without a card cleaner. The mixing ratio of foreign materials on the pepper harvester with a card cleaner was lower at 8.7% and 2.5% for Jeokyoung and AR-Legend than that without a card cleaner, respectively. For the two-way ANOVA results according to the variety and the card cleaner, there was no effect on the separation efficiency of the peppers, but there was an effect on the foreign matter mixing rate.

왕겨풍구의 성능(性能)에 영향(影響)을 미치는 작동요인(作動要因)에 관(關)한 연구(硏究) (The Effects of Operational Factors On the Performance of Husk Separator)

  • 장현택;노상하;정창주
    • Journal of Biosystems Engineering
    • /
    • 제9권1호
    • /
    • pp.22-33
    • /
    • 1984
  • Husk separator is an indispensable equipment in rice milling plants. However, any basic research on the designing and operating criteria of the husk separator have rarely been conducted in Korea. According to the survey results reported recently, grain loss occurs in the process of rice husk separation at custom rice milling plants in Korea and the performance of husk separator has also not been identified. With this regard this study was conducted with a typical commercial husk separator to investigate the effect of the operational factors such as feed rate, blower speed and opening ratio on the velocity distribution in the air duct and the performance of the separator. The results are summerized as follows: 1. The average wind velocity in the primary air duct increased linearly with the blower rpm and the size of air inlet port in both cases of double type and single type operations. 2. The coefficient of variation in the horizontal wind velocities in the primary air duct was the minimum when the opening ratio was 0.22 ($0.052m^2$ of air inlet port) in both cases of single type and double type operations regardless of the blower speeds used in this test. The average wind velocity at the upper part of air duct was greater by 2-5 m/s than the velocity at the bottom part in double type operation. In case of single type operation, however, the average velocity in the middle part was greater than the upper or bottom part when the opening ratio was greater than 0.74. 3. The relationship between the overall effectiveness of separation(Ed for double type and Es for single type) and the average wind velocity (Va) in the primary air duct was expressed in the following quadratic functions. $$Ed=-190.84+106.18Va-10.052Va^2$$ ($r^2$ = 0.97782) $$Es=-223.76+106.23Va-9.1935Va^2$$ ($r^2$ = 0.97029) The average wind velocity required to obtain the overall effectiveness of separation more than 80% ranged from 4.04 m/sec to 5.84 m/sec in case of double type operation, and from 4.70 m/sec to 6.20 m/sec in case of single type. 4. An optimum wind velocity can be obtained with an increase in the blower speed or the size of air inlet port as presented in Figure 8. There was a tendency that the faster the blower speed, the narrower the control range of the air inlet port. 5. The feed rates (1850kg/hr and 2100kg/hr) adopted in this experiment did not bring about a significant difference in both the overall effectiveness of separation and the power consumption. 6. The energy consumption increased cubically with the blower speed but linearly with the size of the air inlet port. On the basis of the results described in items 1, 3, and 6, it would be more economic to adjust the size of the air inlet port larger with a relatively low blower speed than to adjust the size smaller with a relatively high speed.

  • PDF

Control of the Sediment in a Combined Sewer Using a Separation Wall

  • Lim, Bong Su;Kwon, Chung Jin;Kim, Do Young;Lee, Kuang Chun
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.71-75
    • /
    • 2013
  • This study is to evaluate the effects of the separation wall on the sediment quality and quantity in a combined sewer, by surveying the sewer overflow and sediments during a rainfall. Since the separation wall installed in the combined sewer separates the rainfall and the sewage, the flow rate of the sewage is increased, and the amount of the sediment deposited on the sewer is decreased. One sampling point was the outfall of Daesacheon with a separation wall, and the other was the outfall of Gwaryecheon without a separation wall, in Daejeon metropolitan city. The maximum control of the biochemical oxygen demand (BOD) overflow load was more than 38% in the Daesacheon point with the separation wall, during a rainfall of 0.11 mm/hr. The maximum control of the BOD overflow load was 24% in Gwaryecheon without a separation wall, during a rainfall of 1.0 mm/hr. According to the survey results of the sediment in the sewer, the discharged sediment deposited on the sewer in Gwaryecheon point was about 23% to 28% of the total suspended solid during the rainfall. In addition, the average velocity of sewage in the presence of sediment was about 0.30 m/s, and if the separation wall is installed, it was expected to be about 1.01 m/s, that is 3.4 times more than the same conditions, resulting in the reduction of the sediment deposit.