• 제목/요약/키워드: average particle diameter

검색결과 246건 처리시간 0.026초

THE DISTRIBUTION OF DIGESTA PARTICLES AND MEAN PARTICLE SIZE OF DIGESTA OBTAINED FROM THE DIVERSE PARTS OF THE GASTROINTESTINAL TRACT OF RUMINANTS

  • Sekine, J.;Fujikura, T.;Oura, R.;Asahida, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권1호
    • /
    • pp.13-18
    • /
    • 1992
  • Three cattle, a sheep and a goat were slaughtered to determine the distribution of digesta particles and mean size of digesta particles. Aliquot samples of digesta in the diverse sites of the digestive tracts were fractionated by a wet sieving technique. Fractionated particles were analyzed by the magnetic grid analyzer system constructed by authors. Results showed that the proportion of particles in digesta was similar among the omasum, abomasums cecum, colon and rectum, but that for the reticulo-ruminal digesta was different from the others. The pattern of the mass base frequency distribution of particles was also similar in the post-ruminal digesta. Average Heywood's diameter (the diameter equivalent to that of a circle with equal area to a projected area of a given particle) was about 1.2 mm in the reticulo-ruminal digesta and decreased to 0.65 mm for cattle or to about 0.35 mm for sheep and goat in the omasal digesta. Average Heywood's diameter was about the same in the post-ruminal digesta. It is concluded that mean particle size and particle distribution in digesta of the rectum or feces reflect those in digesta of the omasum.

대기 부유분진중의 고무성분 및 납과 아연의 입도별 거동 (Behaviors of Rubber Particles, Lead and Zinc in Atmospheric Particulate Classified by Particle Size Range)

  • 이용근;원정호;김경섭;황규자
    • 한국대기환경학회지
    • /
    • 제2권2호
    • /
    • pp.60-65
    • /
    • 1986
  • Atmospheric particulates were collected at a site near the front gate of the Yonsei University using nine stages Andersen air sampler and the distribution of seasonal particle size was investigated. Rubber, Pb and Zn contents of the collected particulates in each stage were determined. Particle size distribution of atmospheric particulate, which was made by concentration distribution curve method, was usually divided into two groups, course (particles larger than 1 - 2 $\mu m in diameter$) and fine (particles smaller than 1 - 2 \mu m in diameter$) groups, regardless of sampling period. More than 80 percent of the total rubber contents in atmospheric particulates were larger than $5 \mu m$ in diameter, meaning that most of rubber particles were originated from tire tread. After benzene extraction for 4 hrs, the extracts were analyzed by Curie-point pyrolysis gas chromatography for rubber content. Pb and Zn contents were determined by atomic absorption spectroscopy. The annual average concentration of rubber particles was $4.2 \mu g/m^3$, which corresponded to 2.2% of the annual average total suspended particulates. Average concentration of styrene brtadiene rubber was about five times that of natural rubber. Annual average concentrations of Pb and Zn were $1.2 \mu g/m^3 and 0.4 \mu g/m^3$ respectively, which corresponded to about 0.7% and 0.2% of the annual average total suspended particulates.

  • PDF

휴반용 분무기의 Nozzle에 관한 연구(II) (A Study on the Wide Reach Nozzle of Sprayer (ll))

  • 원장우
    • 한국농공학회지
    • /
    • 제15권3호
    • /
    • pp.3053-3058
    • /
    • 1973
  • 1. This study was conducted to examine the effects of change of the short range nozzle hole on the travelling distance. The results of this study are summarized as follows; a) Effect of change of the cap hole diameter on the travelling distance of sprayed particles was generally a linear, the increasing rate was about 0.27. b) When the difference between the sectional area of cap hole and that of grooves of swirl plate, was small the travelling distance was decreased by the decreasing of spraying speed at cap hole. 2. This study was conducted to examine the effects of change of the short range nozzle hole on the size of spraying particles. The results of this study are summarized as follows; a) The diameter of sprayed particles on travelling distances in the short range nozzle did not coincide with the kinetic energy principle derived from the momentum and the resistance. b) The average diameter of sprayed particle between 1m and 3m in which amount of sprayed particle was particularly a great deal, was big, because that some of sprayed particles were absorbed each other on the way to fall c) Effect of increase of cap hole diameter was generally enlarged the average diameter of sprayed particle with small rate.

  • PDF

부산지역 먼지입자의 계절별 특성 (Seasonal Characterization of Particles in Busan Area)

  • 강신묵;조정구
    • 환경위생공학
    • /
    • 제20권3호
    • /
    • pp.17-26
    • /
    • 2005
  • Many researches were focused on the data which obtained from chemical bulk analysis. It is difficult to evaluate source contribution by wet type chemical bulk analysis. In this study, we have reviewed the characterization of individual particle for source identification. We analyzed by SEM/EDX methods. We have obtained average geometric particle diameter measured by optical diameter which were resulted from SEM/EDX image scan, representative physical diameter of individual particle was $3.38\;{\mu}m\;in\;A,\;3.67\;{\mu}m\;in\;B$. In the result of image analysis at each spots particles, both samples non-sphere shapes, C-rich particles. In consequence of chemical analysis of individual particle, each sampling sites some elements.

Effect of NCO Index on the Particle Size of Polycarbonate Diol-based Polyurethane Dispersion

  • Kim, Dong-Eun;Kang, Seung-Oh;Lee, Sang-Ho
    • Elastomers and Composites
    • /
    • 제55권1호
    • /
    • pp.20-25
    • /
    • 2020
  • The effect of the isocyanate index (NCO index) on the particle size and particle size distribution of a waterborne polyurethane dispersion (WPUD) with polycarbonate-diol was determined. The WPUDs were prepared using a conventional acetone process with polycarbonate-polyol (Mn = 2028), 4,4'-methylenebis(cyclohexyl isocyanate) (H12MDI), 2,2-bis(hydroxymethyl) propionic acid (DMPA), and dibutyltin dilaurate catalyst. At NCO index values below 1.5, the number average particle diameter of the WPUDs significantly increased with the NCO index, whereas the particle diameter slightly varied at higher NCO indexes. The dependency of the WPUD viscosity on the NCO index exhibited similar behavior to that of the particle size. The relative values of the full width at half maximum of the WPUD particle distribution curves at various NCO indexes were not influenced by the NCO index.

마그네슘 부유 분진의 입자 체류시간과 발화온도 (Ignition Temperature and Residence Time of Suspended Magnesium Particles)

  • 한우섭
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.25-31
    • /
    • 2015
  • 본 연구에서는 부유 Mg분진의 최소발화온도(MIT)에 있어서 입자 체류시간이 어떠한 영향을 주는지를 실험자료와 입자속도의 계산결과를 사용하여 조사하였다. 평균입경이 증가하면 Mg분진의 MIT는 증가하는 반면에 입자 체류시간(Residence time)은 지수함수적으로 감소하여 분진의 발화 가능성이 저하되는 요인이 될 수 있음을 계산을 통해 확인할 수 있었다. 또한 온도증가에 의한 입자속도에의 영향은 평균입경이 클수록 미세하지만 증가하는 결과가 얻어졌다.

Control of morphology and interfacial tension of PC/SAN blends with compatibilizer

  • Kim, J.H.;Kim, M.J.;Kim, C.K.;Lee, J.W.
    • Korea-Australia Rheology Journal
    • /
    • 제13권3호
    • /
    • pp.125-130
    • /
    • 2001
  • Block copolymers of PC-b-PMMA (polycarbonate-b-polymethylmethacrylate) and PC -b-SAN (polycarbonate-b-(styrene-c-acrylonitrile)), were examined as compatibilizers for blonds of PC with SAN copolymer. The average diameter of the dispersed particles was measured with an image analyser, and the interfacial properties of the blonds were analysed with an imbedded fiber retraction (IFR) technique. The average diameter of dispersed particles and interfacial tension of the PC/SAN blends reached a minimum value when the SAN copolymer contained about 24 wt% AN. Interfacial tension and particle size were further reduced by adding compatibilizer to the PC/SAN blends. PC-b-PMMA was more effective than PC-b-SAN as a compatibilizer in reducing the average diameter of the dispersed particles and interfacial tension of PC/SAN blend. A direct proportionality between the particle diameter and interfacial tension was also observed. The interfacial properties of the PC/SAN blends were optimized by adding a block copolymer and using an SAN copolymer that had minimum interaction energy with PC.

  • PDF

규산 수용액으로부터 분무열분해법에 의한 기공 특성이 제어된 메조기공의 다공성 실리카 분말 합성 (Pore-Controlled Synthesis of Mesoporous Silica Particles by Spray Pyrolysis from Aqueous Silicic Acid)

  • 장한권;이진우;오경준;장희동;길대섭;최정우
    • 한국입자에어로졸학회지
    • /
    • 제8권2호
    • /
    • pp.89-95
    • /
    • 2012
  • Spherical mesoporous silica particles, of which main pore diameter was 3.8 nm, were successfully prepared by spray pyrolysis from aqueous silicic acid. The effect of precursor concentration, reaction temperature, and the addition of urea and PEG on the particle diameter and pore properties such as pore diameter, total pore volume, and specific surface area were investigated by using FE-SEM, particle size analyzer, and nitrogen absorption-desorption analysis. With an increase of the precursor concentration from 0.2 M to 0.7 M, the average particle diameter, total pore volume, and specific surface area of the porous silica particles increased from 0.56 to $0.96\;{\mu}m$, 0.434 to $0.486\;cm^3/g$, 467.8 to $610.4\;m^2/g$, respectively. Within the temperature range $(600\;^{\circ}C{\sim}800\;^{\circ}C)$, there was no significant difference in the pore diameter, total pore volume, and specific surface area. In addition, the addition of urea as an expansion aid led to slight increases in particle diameter, pore diameter, and specific surface area. However, when the polyethylene glycol (PEG) as an organic template was used, the total pore volume of porous particles increased dramatically.

익산시의 부유먼지에 관한 연구 (Studies on the Total Suspended Particulates in Iksan City.)

  • 전병영
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

초고속 미세 액적 충돌을 이용한 나노미터 크기 입자상 오염물질의 세정에 대한 CFD 시뮬레이션 (CFD simulation of cleaning nanometer-sized particulate contaminants using high-speed injection of micron droplets)

  • 박진효;김정건;이승욱;이동근
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.129-136
    • /
    • 2022
  • The line width of circuits in semiconductor devices continues to decrease down to a few nanometers. Since nanoparticles attached to the patterned wafer surface may cause malfunction of the devices, it is crucial to remove the contaminant nanoparticles. Physical cleaning that utilizes momentum of liquid for detaching solid nanoparticles has recently been tested in place of the conventional chemical method. Dropwise impaction has been employed to increase the removal efficiency with expectation of more efficient momentum exchange. To date, most of relevant studies have been focused on drop spreading behavior on a horizontal surface in terms of maximum spreading diameters and average spreading velocity of drop. More important is the local liquid velocity at the position of nanoparticle, very near the surface, rather than the vertical average value. In addition, there are very scarce existing studies dealing with microdroplet impaction that may be desirable for minimizing pattern demage of the wafer. In this study, we investigated the local velocity distribution in spreading liquid film under various impaction conditions through the CFD simulation. Combining the numerical results with the particle removal model, we estimated an effective cleaning diameter (ECD), which is a measure of the particle removal capacity of a single drop, and presented the predicted ECD data as a function of droplet's velocity and diameter particularly when the droplets are microns in diameter.