• Title/Summary/Keyword: average case setting

Search Result 98, Processing Time 0.034 seconds

A Case Study on the Evaluation of Environmental Health Status Focused on Multiple Impact and Environmental Justice (다중 영향 및 환경정의를 고려한 지역 환경보건수준 평가 사례연구)

  • Park, Choong-hee;Han, Hye-ji;Lee, Young-mee;Yoo, Si-eun;Jung, Da-young;Chu, Yeon-hee
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.22-34
    • /
    • 2020
  • Objectives: Based on the concept of environmental justice, we developed an evaluation model for setting and adopting the direction of environmental health policy using environmental health indicators and statistics from the local governments of Seoul, including environmentally susceptible populations. Methods: We selected a total of 20 variables based on data officially released from national and local governments. After the classification of these variables into the five components of environmental pressure, environmental status, environmental disease, sensitive population, and socioeconomic status, a basic model was constructed to calculate the relative scores of the local governments. Results: The cumulative impact scores for assessment of environmental health status were similar to those of the environmental pressure and status components. The highest five cumulative impact scores fell between 114 and 147. Local government A reported the highest scores and had high environmental pressure, environmental status and socioeconomic status. In addition, the evaluation of the other four local governments indicated that they exhibited above average scores for environmental pressure and environmental status, two did so for environmental disease, and four for sensitive population. Conclusion: We constructed a model to evaluate the environmental health status of the local governments of Seoul based on cumulative impact scores under the concept of environmental justice. As an approach for studying environmentally vulnerable areas through relative ranking, this model was feasible for policy-setting. In addition, this approach would be an analytically useful tool for decision-makers.

Accuracy of Combined Visual Inspection with Acetic Acid and Cervical Cytology Testing as a Primary Screening Tool for Cervical Cancer: a Systematic Review and Meta-Analysis

  • Chanthavilay, Phetsavanh;Mayxay, Mayfong;Phongsavan, Keokedthong;Marsden, Donald E;White, Lisa J;Moore, Lynne;Reinharz, Daniel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5889-5897
    • /
    • 2015
  • Background: The performance of combined testing visual inspection with acetic acid (VIA) and cervical cytology tests might differ from one setting to another. The average estimate of the testing accuracy across studies is informative, but no meta-analysis has been carried out to assess this combined method. Objective: The objective of this study was to estimate the average sensitivity and specificity of the combined VIA and cervical cytology tests for the detection of cervical precancerous lesions. Materials and Methods: We conducted a systematic review and a meta-analysis, according to the Cochrane Handbook for Systematic Review of Diagnostic Test Accuracy. We considered two cases. In the either-positive result case, a positive result implies positivity in at least one of the tests. A negative result implies negativity in both tests. In the both-positive case, a positive result implies having both tests positive. Eligible studies were identified using Pubmed, Embase, Website of Science, CINHAL and COCRANE databases. True positive, false positive, false negative and true negative values were extracted. Estimates of sensitivity and specificity, positive and negative likelihood (LR) and diagnostic odds ratios (DOR) were pooled using a hierarchical random effect model. Hierarchical summary receiver operating characteristics (HSROC) were generated and heterogeneity was verified through covariates potentially influencing the diagnostic odds ratio. Findings: Nine studies fulfilled inclusion criteria and were included in the analysis. Pooled estimates of the sensitivities of the combined tests in either-positive and both-positive cases were 0.87 (95% CI: 0.83-0.90) and 0.38 (95% CI: 0.29-0.48), respectively. Corresponding specificities were 0.79 (95% CI: 0.63-0.89) and 0.98 (95% CI: 0.96-0.99) respectively. The DORs of the combined tests in either-positive or both-positive result cases were 27.7 (95% CI: 12.5-61.5) and 52 (95% CI: 22.1-122.2), respectively. When including only articles without partial verification bias and also a high-grade cervical intraepithelial neoplasia as a threshold of the disease, DOR of combined test in both-positive result cases remained the highest. However, DORs decreased to 12.1 (95% CI: 6.05-24.1) and 13.8 (95% CI: 7.92-23.9) in studies without partial verification bias for the combined tests in the either-positive and both-positive result cases, respectively. The screener, the place of study and the size of the population significantly influenced the DOR of combined tests in the both-positive result case in restriction analyses that considered only articles with CIN2+ as disease threshold. Conclusions: The combined test in the either-positive result case has a high sensitivity, but a low specificity. These results suggest that the combined test should be considered in developing countries as a primary screening test if facilities exist to confirm, through colposcopy and biopsy, a positive result.

Ultrasonic image assessment of the degree of pancreatic fat deposition (췌장 지방 침착 정도에 따른 초음파 영상 평가)

  • Park, Hye-in;Park, Seung-hun;Beak, Yun-seung;Lee, Seon-bin;Lee, Eun-sol;Heo, Yeong-dae;Cho, Jin-young;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.490-492
    • /
    • 2016
  • Pancreatic ultrasound imaging is used to diagnose pancreatic hyperplasia, pancreatic steatosis, pancreatic cancer and the like. If the diagnosis of pancreatic steatosis is pancreatic parenchyma echo shades splashes spleen than in the pancreas ultrasound it determines that the fat is deposited. And research on ultrasound imaging of pancreatic cancer but is actively conducted research studies on pancreatic steatosis is insufficient In addition, pancreatic steatosis is often an error in accordance with the diagnostic criteria are vague and subjective diagnosis of the artisan. This study was a quantitative analysis using the feature value extracting a feature of an image extracted by applying a parameter to the algorithm GLCM image of the normal and pancreatic fat. Setting a region of interest ($5{\times}5pixel$) in the mild 89 case, moderate 89 case, severe 89 case, total image 267 case using GLCM algorithm, and using the Autocorrelation, Sum average, Sum of squares, Sum varience 4 kinds parameter in each image It was analyzed.

  • PDF

Free vibration analysis of rotating beams with random properties

  • Hosseini, S.A.A.;Khadem, S.E.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.3
    • /
    • pp.293-312
    • /
    • 2005
  • In this paper, free vibration of rotating beam with random properties is studied. The cross-sectional area, elasticity modulus, moment of inertia, shear modulus and density are modeled as random fields and the rotational speed as a random variable. To study uncertainty, stochastic finite element method based on second order perturbation method is applied. To discretize random fields, the three methods of midpoint, interpolation and local average are applied and compared. The effects of rotational speed, setting angle, random property variances, discretization scheme, number of elements, correlation of random fields, correlation function form and correlation length on "Coefficient of Variation" (C.O.V.) of first mode eigenvalue are investigated completely. To determine the significant random properties on the variation of first mode eigenvalue the sensitivity analysis is performed. The results are studied for both Timoshenko and Bernoulli-Euler rotating beam. It is shown that the C.O.V. of first mode eigenvalue of Timoshenko and Bernoulli-Euler rotating beams are approximately identical. Also, compared to uncorrelated random fields, the correlated case has larger C.O.V. value. Another important result is, where correlation length is small, the convergence rate is lower and more number of elements are necessary for convergence of final response.

Quantity of Ascorbic Acid in the Parts of Vegetable and Its variation by Cooking Method (상용채소의 부위에 따른 환원형 Ascorbic acid량과 조리방법에 따른 C량의 변화)

  • 강신주
    • Journal of the Korean Home Economics Association
    • /
    • v.4 no.1
    • /
    • pp.589-594
    • /
    • 1963
  • Ascorbic acid has a strong power to reduce other materials, so by using this reducing power we can analise many materials quantitatively. Dihydro-ascorbic acid is quantitatively changed into ascorbic acid under a certain condition, if reduced by hydrogen-sulfide. Dihydro-ascorbic acid also has physiolosical effect, but less effect than ascorbic acid. The effect of dihydro-ascorbic acid is regarded as a half of that of ascorbic acid. Among the analytical methods applying this theory the method using 2.6 dichlorophenol indophenol what called the method of Indophenol is used most widely; so does Hydrazine-method. But comparing these two methods the former shows a little higher rate in analytical value. Vegetable are vital sources for vitamin C. According to the report of the commitee of FAO Korean branch the amount of daily per head average intake of vitamin C is about 70mg in raw materials. Since vitamin C is easily affected by heating or oxidation in Cooking the loss is not a little. Consequntly it is regarded that the actual amount of intake will be much less than basic amount. It is therefore very important to find out that how much percent of the loss there will be in case of cooking, in order to dicide the actual amount of in take as proper nutrition for a person. Therefore this paper intended to give some help in setting a standard amount of V.C intake, by measuring the change of the V.C amount using the general cooking method and by measuring amount of V.C contained in the part of vegetable, used in Korea abundantly.

  • PDF

A Location Information-based Gradient Routing Algorithm for Wireless Ad Hoc Networks (무선 애드혹 네트워크를 위한 위치정보 기반 기울기 라우팅 알고리즘)

  • Bang, Min-Young;Lee, Bong-Hwan
    • The KIPS Transactions:PartC
    • /
    • v.17C no.3
    • /
    • pp.259-270
    • /
    • 2010
  • In this paper, a Location Information-based Gradient Routing (LIGR) algorithm is proposed for setting up routing path based on physical location information of sensor nodes in wireless ad-hoc networks. LIGR algorithm reduces the unnecessary data transmission time, route search time, and propagation delay time of packet by determining the transmission direction and search range through the gradient from the source node to sink node using the physical location information. In addition, the low battery nodes are supposed to have the second or third priority in case of forwarding node selection, which reduces the possibility of selecting the low battery nodes. As a result, the low battery node functions as host node rather than router in the wireless sensor networks. The LIGR protocol performed better than the Logical Grid Routing (LGR) protocol in the average receiving rate, delay time, the average residual energy, and the network processing ratio.

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Comparison between the Spatially Integrated Model and the Spatially Distributed Model in the Nonpoint Source Contaminants of Groundwater (지하수 분산오염원에 대한 공간적분모형과 공간분포모형의 비교)

  • Lee, Do-Hun;Lee, Eun-Tae;Jeong, Sang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.177-187
    • /
    • 1998
  • The spatially integrated model (SIM) which can evaluate temporal variation of groundwater quality is proposed in the stream-aquifer setting entered by nonpoint source contaminants. And the developed SIM included unsaturated soil zone and was tested against the spatially distributed model (SDM) of the coupled advection-dispersion and Richards equations for the various hydrologic and aquifer simulating conditions. The result of the comparison showed that the average concentration responses of saturated aquifer and groundwater outflow between the SIM and the SDM was in good agreement, except for the case of the large dispersivity ratio and thick aquifer system. And it is shown that for the cases of the large dispersivity ratio and thick aquifer system the performance of the nonlinear SIM is better than that of the linear SIM for evaluating the average concentration of groundwater outflow response.

  • PDF

A Study on Evaluation Method of AEB Pedestrian Test (보행자 AEB 시험평가 방법에 관한 연구)

  • Kim, BongJu;Kwon, ByeongHeon;Lee, SeonBong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2018
  • Due to the rapid increase in the number of vehicles, the physical and human losses caused by traffic accidents have become serious social problems. In the global trend, there have been active studies conducted on improving safety level of automobile in order to reduce the number of automobile accident. As a result of such research, traffic accidents continue to decline. In the case of South Korea, however, rate of death by automobile accident is 8.5 per 10,000 people and it is a seven rank among the countries in OECD (Organization for Economic Cooperation and Development). This average rate is almost double compared to average automobile accident rate per 10,000 vehicles, of other OECD countries in 2015. Consequently, many studies and policies currently have been conducted and made for increasing safety of pedestrians; however, they are only emphasizing characteristics of pedestrians and drivers. For this reason, this study suggests scenarios for establishment of test standard corresponding with domestic environment and international standard of AEB (Autonomous Emergency Braking) and conducts a real car test by scenarios by setting up a goal with a function for remaining distance after braking and then examine equation by comparing real car tests results and outcome after calculation. This is a theoretical method to predict a relative remaining distance after AEB prior to conducting a real car test for evaluation of safeness of automobile with AEB and it is expected that it solves problem of complication of real car test.

Real-time data transmission through congestion control based on optimal AQM in high-speed network environment (고속 네트워크 환경에서 최적AQM기반의 혼잡제어를 통한 실시간 데이터 전송)

  • Hwang, Seong-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.923-929
    • /
    • 2021
  • TCP communication and packet communication require transmission control technology to ensure high quality and high reliability. However, in the case of real-time data transmission, an inefficient transmission problem occurs. In order to overcome this problem and transmit the packet reliability, in general, early congestion control using the buffer level as an index was used. Control of the congestion control point and the cancellation point is delayed because the point at which congestion is controlled is based on the buffer level. Therefore, in this paper, not only the buffer level indicator, but also the ideal buffer level, which determines the packet discard probability, is classified so that the transmission rate and buffer level that measure network congestion are close to the level above the optimal setting. As a result, it was shown that the average buffer level can be directly controlled by maintaining the average buffer level by the ideal buffer level set in the experiment to prove the proposed method.