• Title/Summary/Keyword: auxiliary transformer

Search Result 116, Processing Time 0.027 seconds

Voltage-Fed Push-Pull PWM Converter Featuring Wide ZVS Range and Low Circulating Loss with Simple Auxiliary Circuit

  • Ye, Manyuan;Song, Pinggang;Li, Song;Xiao, Yunhuang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.965-974
    • /
    • 2018
  • A new zero-voltage-switching (ZVS) push-pull pulse-width modulation (PWM) converter is proposed in this paper. The wide ZVS condition for all of the switches is obtained by utilizing the energy stored in the output inductor and magnetizing inductance. As a result, the switching losses can be dramatically reduced. A simple auxiliary circuit including two small diodes and one capacitor is added at the secondary side of a high frequency (HF) transformer to reset the primary current during the circulating stage and to clamp the voltage spike across the rectifier diodes, which enables the use of low-voltage and low-cost diodes to reduce the conducting and reverse recovery losses. In addition, there are no active devices or resistors in the auxiliary circuit, which can be realized easily. A detailed steady operation analysis, characteristics, design considerations, experimental results and a loss breakdown are presented for the proposed converter. A 500 W prototype has been constructed to verify the effectiveness of the proposed concept.

Electromagnetic Retarder's Power Recovery Device and Voltage Control (전자기형 리타더의 전력회수장치 및 전압제어)

  • Jung, Sung-Chul;Yoon, In-Sik;Ko, Jong-Sun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • Usually, large-sized buses and trucks have a very high load. In addition, frequent braking during downhill or long-distance driving, causes the conventional method using the brake friction to have a problem in safety because of brake fade and brake burst phenomenon. Auxiliary brakes dividing the braking load is essential. Hence, environment-friendly auxiliary brakes, such as contactless brake rather than the engine auxiliary brake system are needed. A study aimed at improving the energy efficiency by recharging electric energy with changing mechanical to electrical energy that occurs when braking is actively in progress. In this paper, the voltage control method is utilized to recover the electric energy generated in the electromagnetic retarder instead of the eddy current. To regenerate the braking energy into the electrical energy, the resonant L-C circuit is configured in the retarder. The voltage generated in the retarder is simply modeled as a transformer. However, retarder voltage control in this paper is simulated by modeling the induction generator because this induction generator modeling is more practical than transformer modeling. The changes in the voltage of the resonance circuit, which depends on the switch pulse duration of the control device, were analyzed. A PI controller algorithm to control this voltage is proposed. The feasibility of modeling retarder and voltage controller are shown by using MATLAB Simulink in this paper.

New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • Yang, Seung-Uk;Choe, Gyu-Ha;Mok, Hyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Now, in this paper, going to present you with an Idea related to a new inverter of multi-step voltage source, that Is, the double-connected 12-step inverter with an auxiliary circuit. It possibly can be 24-step inverter with 3-phase voltage source which will enable us make full application even to medium and high power-level Motor drive, UPS, STATCOM, SVC, etc. in which the PWM method could not be employed. 24-step operation can be obtained from the link between the existing 12-step inverter and the additional auxiliary circuit in which the transformer of auxiliary circuit generates ripple voltage delivered to the inverter. Through a lot of experiments and simulations, (from which the validity of this scheme is confirmed,) we came to the conclusion that the increase of the primary winding number on transformer by 2N(N=1,2,3....) leads to the 12M-step(M=2,3,4...) inverter. The validity of the proposed scheme is confirmed by the simulated and experimental results.

New Isolated Zero Voltage Switching PWM Boost Converter (새로운 절연된 영전압 스위칭 PWM 부스트 컨버터)

  • Cho, Eun-Jin;Moon, Gun-Woo;Jung, Young-Suk;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.535-538
    • /
    • 1994
  • In this paper, an isolated ZVS-PWM boost converter is proposed for single stage line conversion. For power factor correction, we used the half bridge topology at the primary side of isolation transformer permitting switching devices to operate under ZVS by using circuit parastics and operating at a fixed duty ratio near 50%. Thus the relatively continuous input current distortion and small size input filter are also achievable. The ZVS-PWM boost operation of the proposed converter can be achieved by using the boost inductor $L_f$, main switch $Q_3$, and simple auxiliary circuit at the secondary side of isolation transformer. The secondary side circuit differ from a conventional PWM boost converter by introduction a simple auxiliary circuit. The auxiliary circuit is actived only during a short switching transition time to create the ZVS condition for the main switch as that of the ZVT-PWM boost converter. With a single stage, it is possible to achieve a sinusoidal line current at unity power factor as well as the isolated 48V DC output. Comparing to the two stage schemes, overall effiency of the proposed converter is highly improved due to the effective ZVS of all devices as well as single stage power conversion. Thus, it can be operated at high switching frequency allowing use of small size input filter. Minimum voltage and current stress make it high power application possible.

  • PDF

A Novel Hybrid Balun Circuit for 2.4 GHz Low-Power Fully-differential CMOS RF Direct Conversion Receiver (2.4 GHz 저전력 차동 직접 변환 CMOS RF 수신기를 위한 새로운 하이브리드 발룬 회로)

  • Chang, Shin-Il;Park, Ju-Bong;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.4
    • /
    • pp.86-93
    • /
    • 2008
  • A low-power, low-noise, highly-linear hybrid balun circuit is proposed for 2.4-GHz fully differential CMOS direct conversion receivers. The hybrid balun is composed of a passive transformer and loss-compensating auxiliary amplifiers. Design issues regarding the optimal signal splitting and coupling between the transformer and compensating amplifiers are discussed. Implemented in $0.18{\mu}m$ CMOS process, the 2.4 GHz hybrid balun achieves 2.8 dB higher gain and 1.9 dB lower noise figure than its passive counterpart and +23 dBm of IIP3 only at a current consumption of 0.67 mA from 1.2 V supply. It is also examined that the hybrid balun can remarkably lower the total noise figure of a 2.4 GHz fully differential RF receiver only at a cost of 0.82 mW additional power dissipation.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

Development of Planar Transformer and SiC Based 3 kW High Power Density DC-DC Converter for Electric Vehicles (플라나변압기와 SiC 기반의 전기자동차용 3kW 고전력밀도 DC-DC 컨버터 개발)

  • Kim, Sangjin;Suk, Chaeyoung;Hakim, Ramadhan Muhammad;Choi, Sewan;Ryu, Byoungwoo;Park, Sanghun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.112-119
    • /
    • 2021
  • This study proposes a design method of high-power-density and high-efficiency low-voltage DC-DC converters using SiC MOSFET and the optimized planar transformer design procedure based on the figure-of-merit. The secondary rectifying circuit of the phase-shifted full-bridge converter is compared to achieve high power density and high efficiency, and the phase-shifted full bridge converter with a current-doubler rectifier is selected. The planar transformer is designed by the proposed optimized design procedure and verified by FEA simulation. To validate the proposed design method, experimental results from a 3 kW prototype are provided. The prototype achieved 95.28% maximum efficiency and a power density of 2.98 kW/L.

Development of a Large Scale STATCOM Using Double-Connected Multistep Inverter (이중접속방식의 멀티스텝 인버터를 이용한 대용량 STATCOM의 개발)

  • 김태훈;배영상;최세완;이왕하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2004
  • In this paper a large scale STATCOM using double-connected multi-step inverter is proposed and operating principle along with control method is detailed. A simple auxiliary circuit including an interphase transformer is employed to improve output voltage waveform of 12-step into 36-step. The proposed scheme could be a cost effective approach in high power applications such as 10MVar to 30MVar STATCOM. Experimental results from a 2KVA laboratory prototype show validity of the proposed method.

Three-Level ZVZCS DC/DC Converter using a Assistance Power Sources of the RailRoad Vehicles (철도차량 보조전원용 Three-Level ZVZCS DC/DC 컨버터)

  • Rho S.C.;Lim E.K.;Yang S.H.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.880-885
    • /
    • 2003
  • Using a Assistance Power Sources of the Railroad Vehicles Three-Level ZVZCS DC/DC Converter is presented in this paper. The proposed three-Level DC/DC Converter Is to achieved zero voltage and zero current switching for the two Main switches. phase shift method is used a parastic capacitance by reverse recovery characteritics in a inner diode of the switching device. Also. using a diode second part of the Transformer by the simple auxiliary circuit for the achieved zero current switching of the Auxiliary switch. For the ZVZCS movement of the all switching devices is analyzed and verified under a 5kW, in the 100kHz switching frequency.

  • PDF

A Study on The 4-Parallel Operation of PWM Converter for High Speed Train Auxiliary Block (고속전철 보조전원 장치용 PWM컨버터의 4병렬 운전에 관한 연구)

  • Oh, G.W.;Kim, Y.C.;Won, C.Y.;Choi, J.M.;Ki, S.W.;Bae, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1230-1232
    • /
    • 2000
  • To reduce harmonics in the AC line and achieve a unit power factor, A 4 paralled single phase PWM AC/DC converter has been proposed. In this paper, the coupling components are derived analytically from PWM converter input transformer model and control scheme to solve this problem is proposed. Unit power factor was obtained and the AC-side current harmonics were reduced. Simulation results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF