• Title/Summary/Keyword: automatic F0 analysis

Search Result 26, Processing Time 0.018 seconds

Shapes of Vowel F0 Contours Influenced by Preceding Obstruents of Different Types - Automatic Analyses Using Tilt Parameters-

  • Jang, Tae-Yeoub
    • Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.105-116
    • /
    • 2004
  • The fundamental frequency of a vowel is known to be affected by the identity of the preceding consonant. The general agreement is that strong consonants trigger higher F0 than weak consonants. However, there has been a disagreement on the shape of this segmentally affected F0 contours. Some studies report that shapes of contours are differentiated based on the consonant type, but others regard this observation as misleading. This research attempts to resolve this controversy by investigating shapes and slopes of F0 contours of Korean word level speech data produced by four male speakers. Instead of entirely relying on traditional human intuition and judgment, I employed an automatic F0 contour analysis technique known as tilt parameterisation (Taylor 2000). After necessary manipulation of an F0 contour of each data token, various parameters are collapsed into a single tilt value which directly indicates the shape of the contour. The result, in terms of statistical inference, shows that it is not viable to conclude that the type of consonant is significantly related to the shape of F0 contour. A supplementary measurement is also made to see if the slope of each contour bears meaningful information. Unlike shapes themselves, slopes are suspected to be practically more practical for consonantal differentiation, although confirmation is required through further refined experiments.

  • PDF

An analysis of emotional English utterances using the prosodic distance between emotional and neutral utterances (영어 감정발화와 중립발화 간의 운율거리를 이용한 감정발화 분석)

  • Yi, So-Pae
    • Phonetics and Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.25-32
    • /
    • 2020
  • An analysis of emotional English utterances with 7 emotions (calm, happy, sad, angry, fearful, disgust, surprised) was conducted using the measurement of prosodic distance between 672 emotional and 48 neutral utterances. Applying the technique proposed in the automatic evaluation model of English pronunciation to the present study on emotional utterances, Euclidean distance measurement of 3 prosodic elements such as F0, intensity and duration extracted from emotional and neutral utterances was utilized. This paper, furthermore, extended the analytical methods to include Euclidean distance normalization, z-score and z-score normalization resulting in 4 groups of measurement schemes (sqrF0, sqrINT, sqrDUR; norsqrF0, norsqrINT, norsqrDUR; sqrzF0, sqrzINT, sqrzDUR; norsqrzF0, norsqrzINT, norsqrzDUR). All of the results from perceptual analysis and acoustical analysis of emotional utteances consistently indicated the greater effectiveness of norsqrF0, norsqrINT and norsqrDUR, among 4 groups of measurement schemes, which normalized the Euclidean measurement. The greatest acoustical change of prosodic information influenced by emotion was shown in the values of F0 followed by duration and intensity in descending order according to the effect size based on the estimation of distance between emotional utterances and neutral counterparts. Tukey Post Hoc test revealed 4 homogeneous subsets (calm

A Study on Automatic Text Categorization of Web-Based Query Using Synonymy List (유사어 사전을 이용한 웹기반 질의문의 자동 범주화에 관한 연구)

  • Nam, Young-Joon;Kim, Gyu-Hwan
    • Journal of Information Management
    • /
    • v.35 no.4
    • /
    • pp.81-105
    • /
    • 2004
  • In this study, the way of the automatic text categorization on web-based query was implemented. X2 methods based on the Supported Vector Machine were used to test the efficiency of text categorization on queries. This test is carried out by the model using the Synonymy List. 713 synonyms were extracted manually from the tested documents. As the result of this test, the precision ratio and the recall ratio were decreased by -0.01% and by 8.53%, respectively whether the synonyms were assigned or not. It also shows that the Value of F1 Measure was increased by 4.58%. The standard deviation between the recall and precision ratio was improve by 18.39%.

Validation of acid-base titration equivalence between spectroscopic titrator (SPT) and conventional titrators (분광학적 적정기(SPT)와 기존 적정기의 산-염기 적정 동등성 검증)

  • Shin, Jiwon;Kim, Yeajin;Lee, Hyoseong;Shin, Jisun;Yoo, Hyein;Chae, Won-Seok
    • Analytical Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.267-274
    • /
    • 2021
  • Acid-base titration experiments were carried out using the same sample to obtain a direct comparison of analysis results between a new titrator and conventional Spectrator (SPT) titrators. This allowed the confirmation of an endpoint both by spectroscopic detection and by conventional titrators (automatic burette (ABT) and autotitrator (ATT)). Statistical analysis was performed on the measured values (endpoints) obtained using different titrators, to assess their differences by comparison of straightness, equivalence, ANOVA, F-test, and t-test results. The coefficients of determination, confirmed by straightness, were all >0.999. Thus, the null hypothesis that there was no statistical difference could not be rejected. The Bland-Altman analysis method was used to confirm agreement with the new experimental method. No discrepancy was found in the measured values obtained using different titrators used in this study.

A study on purchase and use management of small electric appliances in the urban household. -Mainly Automatic Rice Cooker, Electric Frypan, Toaster and Blender- (도시가정의 소형 전기기구의 구매와 사용관리에 관한 연구 -전기밥솥, 전기 프라이팬, 토우스터, 블렌더를 중심으로-)

  • 이정우
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.2
    • /
    • pp.93-112
    • /
    • 1986
  • The purpose of this study is to clarify which some factors among the socio-demographic factors have effect on the housewives behavior on how to buy small electric appliances and how to use them. The questionnaires were distributed in July 1985 to 491 housewives in Seoul. Satistical methods as percentage, frequency, arithmetic mean, chi-square test, t-test and F-test were used for data analysis. RESULTS : 1) The average rate of possessing the automatic rice cooker is 87.8%, the electric frypan is 81.0%, the toaster is 36.9% and the blender is 86.9%. 2. Generally the frequency of use were low. 3) Generally their knowledge on small electric appliances is low. 4) The ability of management in blender was influenced by age, education and in automatic rice cooker was influenced by only education.

  • PDF

A Study on Noise Automatic Inspection System for Washing Machine Auto-Transmission (세탁기용 자동변속기 (Auto-Transmission)의 이상음 검사자동화 시스템에 관한 연구)

  • 김재열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.310-315
    • /
    • 1998
  • This study includes noise automatic inspection system for washing machine auto-transmission one of modern home necessary. We effort to find and certificate sound noisesource by sound power and sound intensity, and apply to frequency analysis in vibration related sound noise. Still more we have been studying to data acquisition and programming for MS VisualBasic version 5.0. System component is below. 1) Pentium PC for data acquisition. 2) DSO for noise acquisition. 3) S/W for comparison and decision. 4) I/F Board for data communication. Wave form data through the DSO are converting to ASCII code data. The ASCII code through binary converting S/W are to be decision fitness or the badness comparison S/W. Finally, we will making noise monitoring system and automatic inspection system.

  • PDF

Development of Automatic Program for Noise Inspection of Auto-transmission (자동변속기(Auto-Transmission)의 이상음 검사자동화 시스템개발)

  • 김재열
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.9-18
    • /
    • 2000
  • This study includes noise automatic inspection system for washing machine auto-transmission one of modern home necessary. We effort to find and certificate sound noise source by sound power and sound intensity, and apply to frequency analysis in vibration related sound noise. still more we have been studying to data acquisition and programming for MS VisualBasic version 5.0. System component is below. 1) Pentium PC or data acquisition. 2) DSO for noise acquisition. 3)S/W for comparison and decision. 4) I/F Board for data communication. Wave form data through the DSO are converting to ASCII code data. The ASCII code through binary converting S/W. Finally we will making noise monitoring system and automatic inspection system.

  • PDF

An Algorithm for Self-determing Degrees-of-freedom of Shifting Systems (변속 시스템의 자유도 자율 판단 알고리즘)

  • 임원식;박영일;이장무
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.202-214
    • /
    • 1997
  • In automotive industries, one of major issues is the shifting shock, which is brought out when two clutches are engaged in an automatic transmission. The engagement and disengagement if two clutches means the variation of the D.O.F(degree of freedom) of system. Therefore to analyze the shifting performance, the variation of D.O.F should be considered in detail. Generally, the programs for analyzing the shifting transients have been developed as the problem-dependent codes because the artificial maris were usually used to indicate the change of shifting phase. To develop a software applicable to a general mechanism of transmissions, a self-determining algorithm of D.O.F must be applied. Through the experiences for the last several years, a generalized analysis software of shifting mechanism(so called by POTAS-MSM Version 2.0) has been developed. In this study, some major ideas of the software and the concept for the analysis of shifting characteristics are presented. In addition to that, this paper shows how to self -determine D.O.F of he multi-slipping systems using the stick-slip criterion on a single slipping mechanism. By using this software, the shifting characteristics of a vehicle are analyzed and compared with the experimental results.

  • PDF

Applying Lexical Semantics to Automatic Extraction of Temporal Expressions in Uyghur

  • Murat, Alim;Yusup, Azharjan;Iskandar, Zulkar;Yusup, Azragul;Abaydulla, Yusup
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.824-836
    • /
    • 2018
  • The automatic extraction of temporal information from written texts is a key component of question answering and summarization systems and its efficacy in those systems is very decisive if a temporal expression (TE) is successfully extracted. In this paper, three different approaches for TE extraction in Uyghur are developed and analyzed. A novel approach which uses lexical semantics as an additional information is also presented to extend classical approaches which are mainly based on morphology and syntax. We used a manually annotated news dataset labeled with TIMEX3 tags and generated three models with different feature combinations. The experimental results show that the best run achieved 0.87 for Precision, 0.89 for Recall, and 0.88 for F1-Measure in Uyghur TE extraction. From the analysis of the results, we concluded that the application of semantic knowledge resolves ambiguity problem at shallower language analysis and significantly aids the development of more efficient Uyghur TE extraction system.

Analysis of Residual Solvents of [F-18]FDG Using Gas Chromatography (기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석)

  • Kim, Dong-Il;Lee, Il-Jung;Kim, Shi-Hwal;Chi, Yong-Gi;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The general test method of the Korean Pharmacopeia specifies the test method on the clauses of quality control after manufacturing. According to KFDA Guidance for Medicines, standards of residual solvents regulates the maximum permissible dose of acetonitrile as 400 ppm, ethanol as 5,000 ppm, and acetic acid as 5,000 ppm. This study aims at identifying the type of resiual solvents in the final [F-18]FDG vial of an automatic synthesizer and measure its residual quantity. Materials and Methods: The center carried out residual solvents test of [F-18]FDG injection using Agilent Technologies 7890A with a Flame Ionization Detector. The column of Agilent Technologies 7890A used in measuring of residual solvents was CP WAX column ($30m{\times}0.53mm{\times}1.0{\mu}m$) and analysis condition was split mode 1:1 at the initial temperature $70^{\circ}C$ which was increased $20^{\circ}C/minute$ after two minutes and maintained at the final $140^{\circ}C$ for two minutes. The analysis method was as following: Firstly, ethanol-acetonitrile-acetic acid mixture was classified into four types of concentration (250-25-250 ppm, 1,000-100-1,000 ppm, 3,000-300-3,000 ppm, and 6,000-600-6,000 ppm), and $1.0{\mu}L$ of each type of concentration was injected into gas chromatography followed by an analysis of its peak domain. Then, a calibration-curve by the external standard method was drawn based on the analysis result. Results: While ethanol and acetonitrile were detected in TRACERlab MX, FASTlab had additional acetic acid. The residual quantity of the ethanol-acetonitrile-acetic acid mixture evaluated using the calibration-curve was average 72 ppm ethanol, 54 ppm acetonitrile, and 1030 ppm acetic acid for FASTlab, whereas average 439 ppm ethanol and 79 ppm acetonitrile for TRACERlab MX. This indicated that both of them were within the maximum permissible dose. Conclusion: Solvent residues in the [F-18]FDG injection were all within maximum permissible doses and proper to be used to examine a patient. The result indicated that types and quantities of solvent resides of radioactive pharmaceuticals vary depending on the automatic synthesizer.

  • PDF