• Title/Summary/Keyword: author image

Search Result 216, Processing Time 0.022 seconds

THE STUDY OF THE INTERPRETATION OF THE TMJ RADIOGRAPHY USING SUBTRACTION TECHNIQUE (Subtraction법을 이용한 악관절 X-선사진 판독에 관한 연구)

  • Na Choon-Wha;Yoo Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.175-181
    • /
    • 1987
  • The purpose of this study is to know the value of the photographic subtraction technic in the transcranial oblique lateral projection of the TMJ. The author examined the transcranial oblique lateral projection radiographs which comprise 50 cases of 32 persons, compared the transcranial oblique lateral projection films and those subtraction films. The following results were obtained. 1) The condyle at closed jaw position had showed a reversed tone image, but the condyle at the opening position had showed a re-reversed ordinary image. Both condyles had showed one subtraction film because radiographic interpretation of TMJ was easy. 2) On 50 cases of subtraction films, 46 cases had showed same radiographic images compared with trascranial oblique lateral projection films. Four cases (3 cases of erosion, 1 cases of sclerosis) had showed additional changes of images so that capability of interpretation was improved.

  • PDF

Strategy for the Patient with Tuberculum Sellae Meningioma Combining Bilateral Internal Artery Aneurysm

  • Cha, Ki-Yong;Park, Sang-Keun;Hwang, Yong-Soon;Kim, Tae-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.2
    • /
    • pp.151-154
    • /
    • 2005
  • A 43-year-old woman was admitted with the chief complaint of progressive visual disturbance and her brain radiological studies disclosed well demarcated tumor at tuberculum sellae area and bilateral mirror image paraclinoid internal carotid artery saccular aneurysms. A larger left side aneurysm was pointing medialy and almost encased by the tumor. Although a brain tumor and intracranial aneurysm can be simultaneously treated by surgery, the high risk of intra-operative aneurysm rupture should be considered. Therefore, the author secondly performed tumor resection after the endovascular embolization of the aneurysm which was embedding the tumor using a Guglielmi detachable coil. After successful treatment of the patient with tuberculum sellae meningioma associated with bilateral mirror image paraclinoid aneurysms using endovascular and surgical techniques, the authors present the case with a review of the related literatures.

PANORAMIC RADIOGRAPH OF THE FACIAL BONES ACCORDING TO HEAD POSITION (두부위치에 따른 안면골의 파노라마방사선사진상)

  • Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.25-29
    • /
    • 1989
  • The author has evaluated the panoramic image clarity of the midfacial anatomic structures in dry skull according to the skull position. The radiopaque markers were attached to the anatomic structures: infraorbial rim, upper and lower borders of zygomatic arch, pterygomaxillary fissure, lateral pterygoid plate, pyriform aperture of nasal cavity, lateral wall of maxilla, orbital floor, infraorbital foramen, and nasal floor. Position of the skull were divided into four groups. standard, 25mm forward, chin-down, chin-up position. The results were as follows: 1. The pyriform aperture of nasal cavity, lateral wall of the maxilla, orbital floor, infraorbital foramen and nasal floor did net cast any discernible image. 2. Nearly all images of midfacial structures were blurred in the chin-up position. 3. The forward position provided good visualization of the maxillary sinus. 4. The chin-down position provided good visualization of the zygomatic arch, pterygomaxillary fissue, and lateral pterygoid plate.

  • PDF

An Application of Single Screen-Film System on General Radiography (일반(一般)X선촬영(線撮影)에 있어서 편면(片面)시스템의 응용(應用))

  • Park, Myeong-Hoan;Cho, Joon-Suk;Song, Jae-Kwan;Huh, Joon;Yoo, Jang-Soo
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.15-20
    • /
    • 1990
  • In clinical fields, single screen-film system will be generalized according to high speed and high image qualify of intensifying screen film system in future. In single screen-film system, for imaging the best image, we must choice good film according to speed and gredient. Double screen-film system will be replaced single screen film system in general radiography. Author has thought that single screen film system will be developed new diagnosis area according to X-Ray films.

  • PDF

Developement of Data Process Techniques of Land Information System Using Satellite Image (인공위성 영상을 이용한 토지정보시스템의 자료처리 기법 개발)

  • 강인준
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.2
    • /
    • pp.115-118
    • /
    • 1991
  • Land information system is a data base describing physical or legal characteristics of land areas, sometimes called a land records system. The digital remote sensor data is useful to calculate some fundamental statistics of the spectral data. This normally involves computing the minimum and maximum value for each band imagery, the mean, the standard deviation, a variance-covariance matrix, and frequencies of brightness values in each channel which are used to produce histograms. In this paper, author emphasize scanning for aerial photos, and next paper will be scanning for satellite image.

  • PDF

3D Face Modeling using Face Image

  • Kim, Sanghyuk;Ban, Yuseok;Park, Changhyun;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.10-12
    • /
    • 2015
  • Purpose It has been stated that patient satisfaction is the crucial factor for determining success in plastic surgery. The convergence of medical science and computer vision has made easier to satisfy patients who wants to have plastic surgery. In this paper, we try to apply 3D face modeling in plastic surgical area. Materials and Methods The author introduces a method for accurate 3D face modeling techniques using a statistical model-based 3D face modeling approach in a mirror system. Results We could successfully obtain highly accurate 3D face shape results. Conclusion The method suggested could be used for acquiring 3D face models from 2D face image and the result obtained from this could be effectively used for plastic surgical areas.

A Margin-based Face Liveness Detection with Behavioral Confirmation

  • Tolendiyev, Gabit;Lim, Hyotaek;Lee, Byung-Gook
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.187-194
    • /
    • 2021
  • This paper presents a margin-based face liveness detection method with behavioral confirmation to prevent spoofing attacks using deep learning techniques. The proposed method provides a possibility to prevent biometric person authentication systems from replay and printed spoofing attacks. For this work, a set of real face images and fake face images was collected and a face liveness detection model is trained on the constructed dataset. Traditional face liveness detection methods exploit the face image covering only the face regions of the human head image. However, outside of this region of interest (ROI) might include useful features such as phone edges and fingers. The proposed face liveness detection method was experimentally tested on the author's own dataset. Collected databases are trained and experimental results show that the trained model distinguishes real face images and fake images correctly.

Research of Character Design in Side-scrolling Horror Puzzle Games

  • Yi, Qi;Chung, Jeanhun
    • International journal of advanced smart convergence
    • /
    • v.11 no.2
    • /
    • pp.77-82
    • /
    • 2022
  • The third-person side view game perspective of side-scrolling games makes playing such games a completely different gaming experience from other traditional games. Nowadays, many game elements are combined with each other, and horror and puzzle elements are often combined to appear in side-scrolling games, bringing players a unique gaming experience. In such games, players seem to be watching their own manipulation of characters. The performance is the same as a stage play, so how to let players better experience such a horror and puzzle-solving stage play through the design of the characters is a key point. However, it is often difficult to accurately classify only from game elements, so first of all, the author will explain the game division of the side scrolling horror puzzle game. After that, this article will analyze the character designs in the three works with high sales and good reputation on Steam, and then draw conclusions.

A STUDY ON SECONDARY IMAGES IN PANORAMIC RADIOGRAPH (파노라마방사선사진에 있어서 이차상에 관한 연구)

  • Cho Dai Hee;Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.81-87
    • /
    • 1984
  • This study was performed to observe the secondary images and to analyse the relationships between the primary and secondary images in panoramic radiograph. Using the Moritta's Panex-EC panoramic x-ray machine and the human dry skull, the author analysed 17 radiographs which were selected from 65 radiographs of the dry skull that attached the radiopaque materials, and the attached regions of the radiopaque materials were the normal anatomical structures which were important and selected as a regions for the evaluation of the secondary images effectively. The results were as follows; 1. The cervical vertebrae showed three images. The midline image was the most distorted and less clear, and bilateral images were slightly superimposed over the posterior border of the mandibular ramus. 2. In mandible, the secondary image of the posterior border of the ramus was superimposed on the opposite ramus region, and this image was elongated from the anterior border of the ramus to the lateral side of the posterior border of the ramus. The secondary image of the condyle was observed on the upper area of the coronoid process, the sigmoid notch and the condyle in opposite side. 3. In maxilla, the posterior region of the hard palate showed the secondary image on the lower part of the nasal cavity and the medial wall of the maxillary sinus. 4. The primary images of the occipital condyle and the mastoid process appeared on the same region, and only the secondary image of the occipital condyle was observed symmetrically on the opposite side with similar shape to the primary one. 5. In the cranial base, the anatomical structures of the midsagittal portions like a inferior border of the frontal sinus, sella turcica, inferior borderr of the sphenoid sinus and inferior border of the posterior part of the occipital bone showed the simillar shape between the primary and secondary images symmetrically. 6. The petrous portion of the temporal bone showed the secondary image on the lateral side of the sella-turcica, and the secondary images of the posterior border of lesser wing, superior border of greater wing of the sphenoid bone and posterior border were observed on the anterior-superior and inferior region of the sella-turcica.

  • PDF

Visual Evaluation of Rib Shadow and Lung Marking during High-voltage Chest Radiography (흉부 고관전압 촬영에 있어서의 늑골음영과 폐문리의 시각적 평가)

  • Choi, Kwon-Kyu;Lee, Chang-Yup;Shin, Dong-Sik;Kim, Chang-Nam;Choi, Ki-Young;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 1992
  • Visual evaluation of rib shadow and lung marking during high voltage chest radiography. The Purpose of this study is to improvement of visual discrimination of pulmonary structures on the conventional chest radiogram. The author prepared an artificial lung using an acryl plate, 8 cm in thickness, which is nearly equivalent to human lung, and 0.6 cm thickness of an aluminum plate for an artificial rib, and 0.5 cm of an acryl plate as a pulmonary vessel as well. And they were used as objects for experimental radiograms. This study performed with gradual increasing densities of film bases in the sequences of densities of 0.6, 0.9, 1.1 and 1.3. We made two combinations of images after multiple and regular cuts, with width of 1 cm, of 4 radiograms at the above mentioned densities of film bases. One image consisted of alternative combination of radiograms taken at densities of 0.6 and 1.3, and the other did at 0.9 and 1.1. The latter image provided better visual perception of pulmonary structures than the former. Experimental radiograms were also taken with 60 kV and 120 kV respectively. After careful evaluation and comparison to images taken on varieties of different densities with combinations and kV, the author had a conclusion that it is advisable to use a high kV X-ray which makes rib shadow subtle, for better visual delineation of pulmonary structures behind ribcage, eventhough contrast of pulmonary structures are decreased at high kV radiogram.

  • PDF