• Title/Summary/Keyword: author image

Search Result 217, Processing Time 0.024 seconds

A Study on Perfectly and Uniformly Structured Code Matrix (완벽하고 균일하게 구성되는 암호행렬에 관한 연구)

  • Yee, Soung-Ryong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.4
    • /
    • pp.741-754
    • /
    • 1997
  • Code matrix is the matrix of which on element and its neighbors are arranged to have a code value. The code matrix was originally designed by the author for developing a vision system but has not been theoretically studied. In this paper some theoretical properties of the code matrix are investigated. The studied characteristics of the code matrix are useful for not only understanding the matrix itself but efficiently restructuring the matrix. A number of transformation functions, which enable the matrix to have different shape, are thus developed based on the investigated properties. The transformation functions are then applied to build a perfectly and uniformly structured square code matrix, which is proven useful in on image processing example. The study in this paper is expected to serve a theoretical background for the application of the code matrix in many areas.

  • PDF

Extended Mixing Rule to Complex Permittivity

  • Wakino, Ki-Kuo
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.4
    • /
    • pp.371-374
    • /
    • 2003
  • Various types of equation for mixing rule on permittivity of mixture have been proposed, but none of these is not perfect because of the inconsistency between the actual geometrical configuration and the basic model for calculation. Serial model and parallel model are lower and upper extremes of mixing manner, the apparent permittivity of any other type of mixture stay between these two extreme states. For the random mixture of the stumpy fine particles, customarily the logarithmic mixing rule has been applied. But, the logarithmic mixing rule does not give the proper value of permittivity in low or high mixing rate of constituent. The author proposed the new mixing rule that gives better consistency with measured value in whole mixing range compared to the logarithmic rule. In this paper, a desirable refinement on the equation proposed in the previous paper is made to adapt to thr configuration image of actual compound and then the equation has been expanded to the complex permittivity to apply the mixing rule on the dissipative materials cases.

Differences Between Facial Skin Temperature of the Paralyzed Side and Those of the Normal side in Essential Blepharospasm patients. (포륜진도 환자의 건측-환측 안면부 피부온도차이에 관한 연구)

  • Gang, Eun-Gyo;Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.10 no.3
    • /
    • pp.113-119
    • /
    • 2007
  • Objectives Benign essential blepharospasm is a progressive neurological disorder characterized by involuntary muscle contractions and spasms of the eyelid muscles. The aim of this study is to provide evidence of differences between facial skin temperaure of the paralyzed side and normal side in Essential Blepharospasm patients. Methods The author studied 13 patients with Essential Blepharospasm. We measured skin temperature of the forehead, zygoma area of the paralyzed side and those of the normal side with The Digital Infrared thermal image. Results There were no significant facial skin temperature differences between the paralyzed side and normal side. Conclusions Thermography is a useful diagnostic tool. But we expect that it is essential to diagnose a disease correctly at an early stage and to find a prompt treatment by introducing and utilizing a simple nonivading diagnofic method other than Thermography.

The Image of Nursing projected in Newspapers (신문에 나타난 간호의 이미지에 관한 연구)

  • 정면숙;강영실
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.1
    • /
    • pp.16-28
    • /
    • 1993
  • The purpose of this study was to identify the im-. age of nursing, that is, to see how nursing is viewed in newspapers. Articles about nursing from two Korean daily newspapers from Jan. 1, 1987 to Dec.31, 1991 were examined for subject, type, attitude and author-ship. The inter-rater reliability was 0.89(by The Holsti method). The major findings were as follows : 1. The total number of articles were 110. 2. As for the subjests matter, articles related to professional nursing activities appeared most frequently(29.6%) , there about labor issues and activity to promote nurses's job climate 19.4%, and about official activities of nursing 11.2%. 3. Commentary articles appeared most frequently(41.2%) , Other article forms were straight news(27. 1%), contribution(17.6%) and inter-views (10.6%). 4. Feature stories acounted for 62.4% and news articles for 37.6%. Most of the articles were of national interests(96.5%), the rest(3.5%) of news from abroad. 5. Articles favorable toward nursing accounted for 54.1%, neutral 28.2%, negative 17.6%. 6. Many articles were written by the reporters (66.3%).

  • PDF

A STUDY OF THE FOCAL TROUGH IN ORTHOPANTOMOGRAPH (Orthophantomograph에 있어서 상층면적에 관한 연구)

  • Choi Chong-Ho;Khim Jhai-Dhuck
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.137-143
    • /
    • 1991
  • In the study of the focal trough of panoramic radiograph using Panoura Eight-S (the Yoshida company), a series of 63 X-ray films were taken with the 8-19 metal pins placed in the holes of the plastic model plate and evaluated by 4 observers. The author analized the focal trough defined by the sharpness criteria and calculated dimension of focal trough in the horizontal plane. The results were as follows; 1. Focal trough was not continued in the anterior region within a very high degree of sharpness. 2. With optional sharpness, the width of anterior and posterior focal trough was approximately l3㎜ and 60㎜ respectively. 3. The focal trough was narrow in the anterior region and was flared laterally with symmetry in posterior region. 4. Sharp image began to show at the position of 18㎜ posteriorly from the most anterior position of chin rest.

  • PDF

A review on several methods for fast generation of digital Fresnel holograms

  • Tsang, P.W.M.
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.2
    • /
    • pp.29-32
    • /
    • 2012
  • Computer generated holography (CGH) is technology for generating holograms of synthetic, three dimensional (3D) objects which may not exist in the physical world. The process, however, requires heavy amount of computation as the resolution of a hologram is significantly higher than that of a typical optical image. This paper reviews four modern techniques for fast generation of digital Fresnel holograms which are important in the development of holographic video systems. The methods that will be described include the virtual window, sub-line, wavefront recording plane (WRP), and the interpolative WRP schemes. These works share the common objective to generate digital Fresnel hologram at a speed that is close to the video frame rate, and with complexity which is realizable with affordable computing and reconfigurable hardware devices. The author will present the principles and realization of these works, as well as some potential area of research in digital holography.

Understanding of Perfusion MR Imaging (관류자기공명영상의 이해)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY (국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구)

  • Kang Yong Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

RADIOGRAPHIC STUDY OF MORPHOLOGY OF MANDIBULAR CONDYLE (하악두 형태의 X선학적 연구)

  • Ahn Hyung Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.15 no.1
    • /
    • pp.7-12
    • /
    • 1985
  • Anatomical anomaly of temporo-madiblar joint and its dysfunction is becoming one of the important problem in dentistry because the number of these cases are increasing rapidly. Applying 'Lateral Transcranial Technic', 'Updegrave method' and 'Denar Accuard 100' to skull and adult with normal occlusion the author obtained following results: 1. Grewcock method combied with cephalostat as one of 'Lateral Transcranial Technic' revealed clear picture but the image of condyle head was tend to incline downward. 2. Direction of central radiation in 'Updegrave method' should be 2 recommended inch upward from auditorial mearus. 3. For functional analysis and correct diagnosis 'Denar Accuard 100' should be highly recommended.

  • PDF

THE STUDY OF THE FOCAL TROUGH IN PANORAMIC RADIOGRAPH (파노라마방사선사진에 있어서 상층면적에 관한 연구)

  • Park Chang Seo;Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-121
    • /
    • 1982
  • In the study of the focal trough of panoramic radiograph, using the Moritta compony Panex-EC a series of 48 exposures were: taken with the 6-18 brass pins placed in the holes of the plastic model plate, then eveluated by 4 observers. The author analyzed the focal trough defined by the sharpness criteria and calcuated the vertical and horizontal magnification range in the corrected focal trough. The results were as follows; 1. Continuous focal trough was not defined in the anterior region using a very high degree of sharpness. 2. As degree of sharpness used in the analysis became less, focal trough was continuous in the anterior and posterior regions, symmetrized bilaterally, and the widths of the focal trough increased more in the posterior region. e. As sharpness criteria were reduced, the percentage range of image magnification increased on both vertical and horizontal magnification, and especially the percentage range of horizontal magnification was greater than that of vertical magnification.

  • PDF