• Title/Summary/Keyword: atomic spin

Search Result 161, Processing Time 0.022 seconds

Detection of Radiation Degradation of LDPE by ESR Spectroscopy (전자스핀공명을 이용한 저밀도 폴리에틸렌의 방사선 열화 검지)

  • Kim Ki-Yup;Lee Chung;Ryu Boo-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.81-86
    • /
    • 2005
  • This study has investigated radiation degradation of low density polyethylene(LDPE). Samples were irradiated up to 800kGy using a $Co^{60}\;\gamma-ray$ at a dose rate of 5kGy/hr in the presence of air atmosphere at room temperature. After irradiation, storing for 2 weeks, free radical measurement of LDPE has established by electron spin resonance(ESR). ESR measurement showed that free radical concentration(FRC) was increased with radiation dose and decreased with the time. The radical types showed alkyl, allyl, and peroxy radical with the irradiation, these changed to peroxy radical with the time.

ESR Signal in Different Cuts of Irradiated Chicken, Pork and Beef

  • Nam, Hye-Seon;Yang, Jae-Seung;Ly, Sun-Yung
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to detect irradiated meat containing bones (chicken, pork and beef), to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals under 9 weeks of storage. Chicken, pork and beef were irradiated with doses 0, 1, 3, 5 and 7 kGy at room temperature using a Co-60 irradiator. Bones were pieced and dried, which were placed in a quartz tube within an Electron paramagnetic resonance (EPR) spectrometer resonator cavity. The irradiated bone presented an asymmetric absorption in shape, different from that of a non-irradiated one. The signal intensity of smaller animals are lower than larger species. Variation was observed between samples of the same species depending on the calcification status of the bone. Moreover different irradiation doses produced different signal areas that make possible to estimate the absorbed dose of treated meat. The ESR signal stability after irradiation was stable in even after a 9 week storage at room temperature.

  • PDF

M ssbauer Study and Atomic Migration in MgFe2O4

  • Lee, Seung Wha;Yoon, Sung Hyun;An, Sung Yong;Kim, Woo Chul;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • v.4 no.4
    • /
    • pp.115-118
    • /
    • 1999
  • $MgFe_2O_4$ has been studied with X-ray diffraction, M ssbauer spectroscopy and vibration sample magnetometer (VSM). The crystal structure of the sample is found to have a cubic spinel structure with a lattice constant of $a_0=8.390$\pm$0.005$\AA$.$ The iron ions at both A (tetrahedral) and B (octahedral)sites are found to be in ferric high-spin states. Its Neel temperature TN is found to be 710$\pm$3 K. The Debye temperature for the A and B sites found to be 417$\pm$5 K and 331$\pm$5 K., respectively. Atomic migation from the A to the B sites starts near 425 K and increases rapidly with increasing temperature to such a degree that 31% of the ferric ions at the A sites have moved over to the B sites by 600 K.

  • PDF

Physical Methods for the Identification of Irradiated Food

  • Yang, Jae-Seung;Lee, Hae-Jung
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.2
    • /
    • pp.203-209
    • /
    • 1998
  • The development of methods for the identification of irradiated foods helps enforce national and international regulations on labelling to ensure the consumer's free choice to buy irradiated or unirradiated foods. and the availabilityof such methods may assist the promotion of international trade in irradiated food products and help prevent abuse of the technology. A number of approaches to determine the physical , chemical, microbiological and biological changes that occur in foods treated with ionizing radiation have been studied. However no single method is universally applicable. Among physical measurements, the leading methods of indentification are electron spin resonance (ESR) spectroscopy and thermoluminescence(TL). ESR is an established non-destructive method for the analysis of free radicals from their traps and TL is the emission of light from irradiated mineral extracts by heating. Viscosity of carbohydrate polymers by causing chain breaks by irradiation, measuring the impedance of potatoes and detection of gases produced radiolytically are promising techniques for identification purposes. Irradiated water-containing foods show significant supercooling when monitored with a differential scanning calorimeter (DSC), which can be applied to identifying irradiated ones.

  • PDF

Effect of Storage Conditions on Graft of Polypropylene Non-woven Fabric Induced by Electron Beam (전자선 조사된 폴리프로필렌 부직포의 그라프트에 있어 보관조건이 미치는 영향)

  • Lee, Jin Young;Jeun, Joon-Pyo;Kang, Phil-Hyun
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2015
  • In this study, we fabricated effect of storage conditions on graft of polypropylene (PP) non-woven fabric induced by electron beam. The electron beam irradiations on PP non-woven fabric were carried out over a range of irradiation doses from 25 to 100 kGy to make free radicals on fabric surface. The radical measurement was established by electron spin resonance (ESR) for confirming the changes of the alkyl radical and peroxy radical according to effect of storage time, storage temperature and atmosphere. It was observed that the free radicals were increased with irradiation dose and decreased with storage time due to the continuous oxidation. However, the radical extinction was significantly delayed due to reduced mobility of radicals at extremely low temperature. The degree of graft based on the analysis of ESR was investigated. The conditions of graft reaction were set at a temperature: $60^{\circ}C$, reaction time: 6 hours and styrene monomer concentration: 20 wt%.

Comparison of Photostimulated Luminescence, Thermoluminescence, and Electron Spin Resonance Spectroscopic Analyses on Dried-spices Irradiated by Gamma Ray and Electron Beam (감마선 및 전자선 조사 처리 건조향신료에 대한 광자극발광, 열발광 및 전자스핀공명의 분광학적 분석 비교)

  • Jeong, Jin-Hwa;Ahn, Jae-Jun;Baek, Ji-Yeong;Kim, Hyo-Young;Kwon, Joong-Ho;Jin, Chang-Hyun;Jeong, Il-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.256-261
    • /
    • 2014
  • This study was conducted to determine the effect of gamma-ray and electron-beam irradiation on dried spices (black pepper, red pepper, parsley, and basil) using the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods. The spices were irradiated at 0, 1, 5, and 10 kGy. All non-irradiated spices had photon counts (PCs) less than 700 PCs. The PCs of three irradiated spices (red pepper, parsley, and basil) were clearly distinguishable from those of non-irradiated ones, exhibiting PSL signals higher than 5000 PCs. However, negative PSL counts (<700 PCs) were obtained for most irradiated black pepper, except those irradiated with 5 kGy gamma rays and 10 kGy electron-beams. TL glow curves of the irradiated spices showed a higher peak at $150-250^{\circ}C$. TL ratios were found to be less than 0.1 for non-irradiated spices and higher than 0.1 for irradiated ones. No ESR signal was observed for any irradiated spice except red pepper, which displayed cellulose-based ESR spectra. Therefore, the results suggest that the PSL, TL, and ESR methods are effective detection techniques for dried spices irradiated with electron beams as well as gamma rays.

Identification of Irradiated Food Additives by Photostimulated Luminescence (PSL) Method (Photostimulated Luminescence (PSL) 방법에 의한 국내 유통 분말형 식품가공원료의 방사선 조사 여부 모니터링)

  • Yun, Hyejeong;Hur, Jungmu;Yang, Suhyung;Lee, Byoung-Hun;Kwon, Joong-Ho;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • Photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) analyses were conducted to detect whether 258 kinds of extracted and powdered forms food additives were irradiated or not. In a view of the PSL results, 9 kinds of the extracted and powdered samples (3.2%) showed over 5,000 photon counts $(60sec)^{-1}$ and these samples were judged to be irradiation-positive. Thirty nine kinds of the samples (15.6%) yielded 700~5,000 photon counts $(60sec)^{-1}$ and these samples were grouped into irradiation-potential, while the samples showed below 700 photon counts $(60sec)^{-1}$ sec were judged to be irradiation-negative. TL glow curves for minerals separated from 5 samples were detected at $150^{\circ}C$ with high intensity. However, TL analysis did not apply to other irradiation-positive and irradiation-potential samples because the minerals for TL detection were not separated from the samples. ESR measurements for irradiation-positive and irradiation-potential samples, judged by PSL detection, showed no specific signals to irradiation. The results indicated that PSL could be applied to identify irradiation treatment of extracted and powdered food additives, while TL was optional and ESR was not suitable for detection extracted and powdered food additives.

Irradiation Detection in Korean Traditional Soybean-Based Fermented Powdered Sauces: Data for Establishing a Database for Regulation of Irradiated Foods

  • Choi, In-Duck;Kim, Byeong-Keun;Song, Hyun-Pa;Byun, Myung-Woo;Kim, Myung-Cheol;Lee, Jong-Oak;Lee, Ho-Joon;Kim, Dong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • To facilitate establishing regulations for irradiated foods, Korean traditional soybean-based fermented powdered doenjang (PD), kanjang (PK), kochujang (PKC) and chungkukjang (PC) were irradiated at 1, 3, 5 and 7 kGy, and subjected to irradiation detection analyses as part of establishing a database for detecting irradiated foods. Photostimulated luminescence (PSL) and electron spin resonance (ESR) were applied as the detection methods. Using PSL analysis, the irradiated PD, PK and PKC could be easily distinguished from the non-irradiated ones, while irradiation of the PC at 5 kGy or higher was detectable. The ESR spectra of the irradiated PD, PK and PKC exhibited symmetrical multiplet lines, which might be induced from the crystalline sugar, whereas, the PC showed a single signal at the paramagnetic centers. The signal intensity increased with incremental increases of irradiation doses distinguishing the irradiated samples from the control. In addition, the peak height also revealed that irradiation induced an increment in the intensity of single and/or multiplet lines of the ESR signals, resulting in clear confirmation of irradiation. Thus, the data from this study could be used as references for detecting irradiated soybean-based fermented powdered sauces.

Chromatographic Separation of Hydrogen Isotopes by Deactivated Alumina Stationary Phase (비활성 알루미나 고정상을 이용한 수소동위원소의 크로마토그래피 분리)

  • Kim, Kwang Rag;Lee, Sung Ho;Kang, Hee Suk;Chung, Hongsuk;Sung, Ki Woung
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.121-128
    • /
    • 1998
  • In fields of operating or handling a hydrogen isotope facility, and of the technology for nuclear fusion source management, gas chromatography has been used as one of the practical techniques lot separation and enrichment of hydrogen isotopic gases including tritium. Chromatographic separation experiments of the hydrogen isotope mixture (hydrogen, deuterium and tritium) were carried out by use of a commercially available gas chromatograph. An aliquot of gas sample was injected by a specially designed vacuum sampler into the stream of inert carrier gas which went through the separation column under liquid nitrogen temperature. The complete separation of hydrogen isotopic molecules was observed with an alumina adsorbent partially deactivated by coating with 10% manganese chlorine. In addition, fairly good separation conditions were obtained without any appearance of nuclear spin isomers with shorter retention time, which would be available for the practical applications of the hydrogen isotope separation and enrichment.

  • PDF

Identification of Gamma Irradiation of Imported Spice

  • Choi, In-Duck;Kim, Byeong-Keun;Song, Hyun-Pa;Byun, Myung-Woo;Han, Sang-Bae;Suh, Chung-Sik;Kim, Dong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.4
    • /
    • pp.317-323
    • /
    • 2004
  • Photostimulated Luminescence (PSL), Electron Spin Resonance (ESR) and Thermoluminescence (TL) analysis were conducted to detect irradiation treatment of imported whole and ground spices. The screening by PSL detected no irradiation treatment, except un the ground thyme and bay leaves which exhibited photon counts in the intermediate level. Irradiation of the two spices was detected after irradiating them at 1.0, 3.0, 5.0 and 10.0 kGy, and then subjecting them to PSL analysis, which resulted in the significantly low photons of non-irradiated spices compared to that at 1.0 kGy, indicating that the photon counts varied depending on the amount of inorganic mineral debris in the spices. To confirm a successful detection by using PSL, ESR and TL methods, some spices were selected, irradiated at 5.0 and 10.0 kGy, and subjected to the detection methods. PSL identified the irradiated spices except the cassia, which showed very weak PSL sensitivity, but was identified by ESR analysis. Also, the ESR and TL exhibited the typical signals induced by irradiation treatment and were able to successfully detect all of the irradiated spices. In addition, we found a positive correlation between the intensity of ESR and TL signals and irradiation doses.