• Title/Summary/Keyword: atomic ratio

Search Result 1,020, Processing Time 0.03 seconds

Surface Modification of Poly(L-lactide-co-ε-caprolactone) Nanofibers by Electron-beam Irradiation (전자선 조사 방법을 통한 생분해성고분자의 표면개질 특성 평가)

  • Kim, Woo-Jin;Shin, Young Min;Park, Jong-Seok;Gwon, Hui-Jeong;Nho, Young-Chang;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.365-370
    • /
    • 2011
  • Electrospun nanofibers prepared with synthetic biodegradable polymer have some limitations in regulating adhesion, proliferation, and spreading of cells because of their surface hydrophobicity and absence of cell-interaction. In this study, we functionalized the electrospun poly(L-lactide-co-${\varepsilon}$-caprolactone) (PLCL) nanofibers with acrylic acid (AAc) to modulate their surface hydrophilicity using electron-beam irradiation method and then measured grafting ratio of AAc, water contact angle, and ATR-FTIR of AAc-grafted nanofibers. A grafting ratio of AAc on the nanofibers was increased as irradiation dose and AAc concentration were increased. AAc-grafted nanofibers also have higher wettability than non-modified nanofibers. In conclusion, those surface-modified nanofibers may be an essential candidate to regulate cell attachment in tissue engineering applications.

Investigation of the optimum condition for the quantitative analysis of Cu sample by Laser induced breakdown spectroscopy (구리 시료의 정량분석을 위한 LIBS의 최적조건 연구)

  • Kim, Seunghyun;Shin, Heesung;Ju, Junesik;Kim, Hodong
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • A laser induced breakdown spectroscopy (LIBS) measurement was carried out to derive an optimized measurement condition with a high reproducibility and to grow a plasma sphere to 20 mm high under a 600 mtorr vacuum in order to improve an accuracy of measurement. The measurement of the plasma was taken at a 6.0 mm distance, in the direction of a plasma sphere, from a sample. This location belongs to the outer sphere region in the plasma. The calibration curve of 'Ni' and 'Cu' was acquired by the signal intensity ratio and the atomic ratio for the samples, and linear regression of 'Cu' was $R^2$=0.9886, and the linear regression of 'Ni' was $R^2$=0.9988. The accuracy of LIBS was improved pre-existence as the measurement error of 'Ni' was 0.78%.

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

Study on the effect of long-term high temperature irradiation on TRISO fuel

  • Shaimerdenov, Asset;Gizatulin, Shamil;Dyussambayev, Daulet;Askerbekov, Saulet;Ueta, Shohei;Aihara, Jun;Shibata, Taiju;Sakaba, Nariaki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2792-2800
    • /
    • 2022
  • In the core of the WWR-K reactor, a long-term irradiation of tristructural isotopic (TRISO)-coated fuel particles (CFPs) with a UO2 kernel was carried out under high-temperature gas-cooled reactor (HTGR)-like operating conditions. The temperature of this TRISO fuel during irradiation varied in the range of 950-1100 ℃. A fission per initial metal atom (FIMA) of uranium burnup of 9.9% was reached. The release of gaseous fission products was measured in-pile. The release-to-birth ratio (R/B) for the fission product isotopes was calculated. Aspects of fuel safety while achieving deep fuel burnup are important and relevant, including maintaining the integrity of the fuel coatings. The main mechanisms of fuel failure are kernel migration, silicon carbide corrosion by palladium, and gas pressure increase inside the CFP. The formation of gaseous fission products and carbon monoxide leads to an increase in the internal pressure in the CFP, which is a dominant failure mechanism of the coatings under this level of burnup. Irradiated fuel compacts were subjected to electric dissociation to isolate the CFPs from the fuel compacts. In addition, nondestructive methods, such as X-ray radiography and gamma spectrometry, were used. The predicted R/B ratio was evaluated using the fission gas release model developed in the high-temperature test reactor (HTTR) project. In the model, both the through-coatings of failed CFPs and as-fabricated uranium contamination were assumed to be sources of the fission gas. The obtained R/B ratio for gaseous fission products allows the finalization and validation of the model for the release of fission products from the CFPs and fuel compacts. The success of the integrity of TRISO fuel irradiated at approximately 9.9% FIMA was demonstrated. A low fuel failure fraction and R/B ratios indicated good performance and reliability of the studied TRISO fuel.

Uranium Activity Analysis of Soil Sample Using HPGe Gamma Spectrometer (고순도 반도체(HPGe) 감마분광시스템을 이용한 토양 중 우라늄 방사능 분석)

  • Lee, Wan-No;Kim, Hee-Reyoung;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Chang-Woo;Choi, Geun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.105-110
    • /
    • 2010
  • Using N-type HPGe gamma spectrometer, uranium analysis technique of soil sample is developed where the chemical preprocessing is not a necessity. The results of uranium activities using the method presented in this paper were compared with those results with conventional alpha spectrometer and two results were similar from within uncertainty range. Therefore, this new method will be applied in uranium activity analysis of soil sample.

Comparison of Yittria Stabilized Zirconia Electrolytes(YSZ) for Thin Film Solid Oxide Fuel Cell by Atomic Layer Deposition and Sputtering (원자층 증착법과 스퍼터링을 이용한 고체산화물 연료전지용 YSZ 전해질에 관한 연구)

  • Tanveer, Waqas Hassan;Ha, Seung Bum;Ji, Sanghoon;Cha, Suk Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.84.2-84.2
    • /
    • 2011
  • In this research, two thin film deposition techniques, Atomic Layer Deposition and Sputtering are carried out for the fabrication of Yittria Stabilized Zirconia electrolyte for thin film Solid Oxide Fuel Cell. Zirconium to Yittrium ratio for both cases is about 1/8. Scanning Electron Microscope(SEM) image shows that the growth rate per hour for Atomic Layer Deposition is faster than for sputtering. X-ray Photo-electron Spectroscopy(XPS) shows that the peaks of both Zirconia and Yittria shift towards higher bending energy for the case of Atomic Layer deposition and thus are more strongly attached to the substrate. Later, Nyquist plot was used to compare the conductivity of Yittria Stabilized Electrolyte for both cases. The conductivity at $300^{\circ}C$ for Atomic Layer Deposited Yittria Stabilized Zirconia is found to be $5{\times}10^{-4}S/cm$ while that for sputtered Yittria Stabilized Zirconia is $2{\times}10^{-5}S/cm$ at the same temperature. The reason for better performance for Atomic Layered YSZ is believed to be the Nano-structured layer fabrication that aids in along the plane conduction as compared to the columnarly structured Sputtered YSZ.

  • PDF

Effect of Gamma Irradiation on the Structural and Physiological Properties of Silk Fibroin

  • Sung, Nak-Yun;Byun, Eui-Baek;Kwon, Sun-Kyu;Kim, Jae-Hun;Song, Beom-Seok;Choi, Jong-Il;Kim, Jin-Kyu;Yoon, Yo-Han;Byun, Myung-Woo;Kim, Mee-Ree;Yoo, Hong-Sun;Lee, Ju-Woon
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.228-233
    • /
    • 2009
  • This study was conducted to examine the changes in the molecular structure and physiological activities of silk fibroin by gamma irradiation. The results of gel permeation chromatography and sodium dodecyl sulfate-polyacrylamide gel electrophoresis showed that the molecular weight of fibroin was increased depending upon the irradiation dose. Secondary structure of fibroin determined by using circular dichroism revealed that the ratio of $\alpha$-helix was increased up to 10 kGy and then decreased depending upon the irradiation dose. Whereas, the ratio of $\beta$-sheet, $\beta$-turn, and random coil were decreased and then increased with an alteration in the $\alpha$-helix secondary conformation. The 2.2-diphenyl-1-picryl-hydrazil (DPPH) radical scavenging activity of fibroin was increased by gamma irradiation at 5 kGy, but was decreased above 10 kGy depending upon the irradiation dose. Also, the inhibition activities of tyrosinase and melanin synthesis of fibroin were increased by gamma irradiation. These results indicated that gamma irradiation could be used as an efficient method to make fibroin more suitable for the development of functional foods and cosmetics.

Estimation of Mass Discrimination Factor for a Wide Range of m/z by Argon Artificial Isotope Mixtures and NF3 Gas

  • Min, Deullae;Lee, Jin Bok;Lee, Christopher;Lee, Dong Soo;Kim, Jin Seog
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2403-2409
    • /
    • 2014
  • Absolute isotope ratio is a critical constituent in determination of atomic weight. To measure the absolute isotope ratio using a mass spectrometer, mass discrimination factor, $f_{MD}$, is needed to convert measured isotope ratio to real isotope ratio of gas molecules. If the $f_{MD}$ could be predicted, absolute isotope ratio of a chemical species would be measureable in absence of its enriched isotope pure materials or isotope references. This work employed gravimetrically prepared isotope mixtures of argon (Ar) to obtain $f_{MD}$ at m/z of 40 in the magnetic sector type gas mass spectrometer (gas/MS). Besides, we compare the nitrogen isotope ratio of nitrogen trifluoride ($NF_3$) with that of nitrogen molecule ($N_2$) decomposed from the same $NF_3$ thermally in order to identify the difference of $f_{MD}$ values in extensive m/z region from 28 to 71. Our result shows that $f_{MD}$ at m/z 40 was $-0.044%{\pm}0.017%$ (k = 1) from measurement of Ar artificial isotope mixtures. The $f_{MD}$ difference in the range of m/z from 28 to 71 is observed $-0.12%{\pm}0.14%$ from $NF_3$ and $N_2$. From combination of this work and reported $f_{MD}$ values by another team, IRMM, if $f_{MD}$ of $-0.16%{\pm}0.14%$ is applied to isotope ratio measurement from $N_2$ to $SF_6$, we can determine absolute isotope ratio within relative uncertainty of 0.2 %.

Characterization of Poly(acrylic acid) Hydrogel Containing Zinc Oxide Particle Prepared by Radiation (방사선을 이용하여 제조한 zinc oxide 입자 함유 poly(acrylic acid) 하이드로젤의 특성)

  • Park, Jong-Seok;Jeong, Sung-In;Shin, Young Min;Choi, Jong-Bae;Gwon, Hui-Jeong;Lim, Youn-Mook;Jeun, Joon-Pyo;Kim, Hyin-Bin;Oh, Seung-Hwan;Kang, Phil Hyun;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.6 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • In this research, poly(acrylic acid) (PAAc) hydrogels containing zinc oxide particle were prepared by gamma-ray irradiation. PAAc powder was completely dissolved in distilled water at room temperature. Water-insoluble zinc oxide powder were added into the PAAc solution and stirred until totally dissolved. Finally, the mixture was irradiated by gamma-ray irradiation to make crosslinking. The effects of various parameters such as zinc ions' concentration, irradiation doses were varied and investigated in detail. PAAc hydrogels containing zinc oxide particle were characterized by gel content and swelling ratio. Moreover, the antibacterial properties of this material were evaluated by paper diffusion test against the Gram positive and Gram negative bacteria.