• 제목/요약/키워드: atmospheric environment factor

검색결과 356건 처리시간 0.032초

아파트단지 환기경로 파악을 위한 주풍향별 바람장 분석 (An Analysis of Wind Field According to the Prevailing Wind Directions for Understanding of Ventilation Passages in an Apartment Complex)

  • 정우식
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.467-477
    • /
    • 2007
  • A numerical study with Envi-met model is experimented to investigate the characteristics of wind pattern in apartment complex. In all case, most conditions such as wind speed, temperature, and surface features are considered as the same, but wind direction is the only different factor. The wind directions considered in this study have a meaning of prevailing wind direction. When the prevailing wind with the direction of $170^{\circ}$ blows into the complex, the ventilation passage toward the outside of complex is formed and the stagnation of air is not expressed. In case of having the direction of $300^{\circ}$, most evident ventilation passages are composed. When the inflow wind direction is the northeast, $30^{\circ}$, there is some possibility of stagnation phenomenon. This is because the arrangement of buildings makes a right angle with the inflow wind direction.

1993년 8월의 서울지역 시정 연구 (Visibility study in Seoul in Aug., 1993.)

  • 이종훈;백남준;김용표;문길주
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.291-298
    • /
    • 1995
  • An intensive field study was carried out during Aug. 1993 in Seoul to study the characteristics of summertime visibility and diurnal trend of ionic composition of ambient particles. A transmissometer, nephelometer with heated and unheated inlets, PM3 fine particle sampler, and cascade impactor were used to measure optical and particle properties of ambient air. During this study period, a weak smog episode has occurred. Light scattering by particles is the most dominant factor on total light extinction. The effect of light absorption by particles in Seoul is much higher than other major cities in U.S.A. throughout the summer and fall with relatively constant values. The effect of water on $b_{sp}$ was small during the period. The particle size distribution shows a typical bimodal one. Sulfate, ammonium, chloride, and nitrate are the major chemical species in fine fraction aerosols, about 30% of toral mass concentration. Concentraion of sulfate is higher during the daytime while those of nitrate and chloride are higher during the nighttime. Ammonium concentration is constant through the daytime.

  • PDF

서울 동부지역내 작업장 공기질에 관한 조사 연구 (A Study of Workplace Air Quality in the Eastern Seoul)

  • 임창훈;황인조;김동술;김윤신
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.235-247
    • /
    • 1999
  • This study was performed to investigate what was the most serious occupational factors in small scale industries. Twenty-three occupatonally hazardous substances were measured at the five workplaces in the Eastern Seoul during 1995∼1996. Total of 2,020 samples were analyzed by either GC/FID for organic vapors or AAS for heavy metals. From the results of this study noise was the most serious factor at the selected workplaces. Noise level in the metal processing, the printing, and the auto repairing industries exceeded the 8 hr PEL by 19.7%, 13.6%, and 11.6%, respectively. Mean concentrations of toluene in the shoe making and the printing industries exceeded the assessment crieterion by 6.0% and 3.8%, respectively. Further study of risk assessment of occupational exposure may be required to protect workers from hazardous working conditons.

  • PDF

대기 중 다환방향조탄화수소류의 분석 방법간 비교연구 (A Comparative Study on the Analytical Methods of Polycyclic Aromatic Hydrocarbons in the Atmosphere)

  • 박찬구;김민영;정동균;모세영
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.595-606
    • /
    • 2000
  • In order to compare analytical conditions for measuring PAHs(polycyclic aromatic hydrocarbons) in ambient air, a series of experiment were conducted using three different types of extraction methods that include:(1) accelerated solvent extraction (ASE), (2) soxhlet, and (3) sonification methods. Efficiency and relevant analytixal parameters for each of these methods were examined on five different types of solvents that include:(1) 10% diethyl ether in n-hexane(v/v), (2) dichloromethane, (3)cyclohexane.(4) toluene, and (5) Benzene: ethanol (4:1). Comparison of extraction efficiency for various combinations between methods and solvents was made through an application of both internal and external standard calibration techniques. The extraction efficiency tests, when checked using both internal and external standards, allowed us to derive meaningful comparison among different techniques and among solvents.

  • PDF

도시소각로에서 Polychlorinated-dibenzofurans (PCDFs)의 생성 예측 (Prediction of Polychlorinated-dibenzofurans (PCDFs) Formation in Municipal Waste Incinerator)

  • 류재용;서정민
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.842-850
    • /
    • 2006
  • The role of chlorination reactions in the formation of polychlorinated dibenzofurans (PCDFs) in a municipal waste incinerator was assessed using a chlorination model for predicting PCDF isomer distributions. Complete distributions of PCDF congeners were obtained from a stoker-type municipal waste incinerator operated under 13 test conditions. Samples were collected from the flue gas prior to the gas cleaning system. While total PCDF yields varied by a factor of five to six, the distributions of congeners were similar. A chlorination model, dependent only on the observed distribution of monochlorinated isomers, was developed to predict the distributions of poly-chlorinated isomers formed by chlorination of dibenzofuran (DF). Agreement between predicted and measured PCDF isomer distributions was high for all homologues, supporting the hypothesis that DF chlorination can play an important role in the formation of PCDF byproducts.

시멘트산업의 온실가스 배출저감 시나리오 분석 (Analysis of the Green House Gas Reduction Scenarios in the Cement Manufacturing Industry)

  • 김현석;강희정
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.912-921
    • /
    • 2006
  • This study examines greenhouse gas reduction potentials in cement manufacturing industry of Korea. An energy system model in the MARKAL (MARKet ALlocation) modeling framework was used in order to identify appropriate energy technologies and to quantify their possible implications In terms of greenhouse gas reduction. The model is characterized as mathematical tool for the long term energy system analysis provides an useful informations on technical assessment. Four scenarios are developed that covers the ti me span from 2000 to 2020. Being technology as a fundamental driving factor of the evolution of energy systems, it is essential to study the basic mechanisms of technological change and its role in developing more efficient, productive and clean energy systems. For this reasons, the learning curves on technologies for greenhouse gas reduction is specially considered. The analysis in this study shows that it is not easy to mitigate greenhouse gas with low cost in cement manufacturing industry under the current cap and trade method of Kyoto protocol.

겨울철 서울도심의 대기중 부유분진의 특성 (The Characteristics of Suspended Particulate Matters in Downtown Seoul During Winter Period)

  • 김신도;김종호;이정주
    • 한국대기환경학회지
    • /
    • 제8권2호
    • /
    • pp.105-111
    • /
    • 1992
  • The characteristics of suspended particulate matters(dust) in Seoul had been studied. The effects of various environmental factors, such as passengers, motor vehicles, wind velocity, wind direction, temperature and humidity were examined during the study period. It was shown that the dust emission occurred through the heating was the major source, and the contribution of passengers and motor vehicles was relatively negligible during the night. It was also revealed that the number concentration between $0.5{\mu}m$ and $2.0{\mu}m$ was increased due to the attachment among the dusts and mists by the increased humidity during the night. Considering the fact that the particles larger than $2{\mu}m$ take the most part of weight concentration, it was suggested that the PM-10 method which considered respirable particle as a weighting factor should be adapted in the evaluation air quality.

  • PDF

1994년 6월 서울지역 시정장애의 측정 및 분석 (Measurement and Analysis of Visibility lmpairment during June, 1994 in Seoul)

  • 백남준;이종훈;김용표;문길주
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.407-419
    • /
    • 1996
  • Characteristics of visual air quality in Seoul have been investigated between June 13 and 21, 1994. Optical properties (extinction coefficient and particle scattering coefficient), meteorological parameters (relative humidity, temperature, wind speed, wind direction, and cloud cover), particle characteristics (mass size distribution, components) were measured and analyzed. During measurement periods, northwest wind with less than 2m/sec of wind speed deteriorates visibility. Effects of relative humidity are though to be not a direct factor which influence to visibility through the size change due to hygroscopic species in aerosol. During the smoggy period both the aerosol mass concentration and fine particle fraction of the size distribution are increased compared to the clear period. Sulfate, organic carbon, and elemental carbon in aerosol are the major species in determining the occurrence and severity of a smog in Seoul.

  • PDF

Atmospheric Concentrations of PAHs in the Vapor and Particulate Phases in Chongju

  • Park, Seung-Shik;Kim, Young-J.;Kang, Chang-H.;Cho, Sung-Yong;Kim, Tae-Young;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E2호
    • /
    • pp.57-68
    • /
    • 2006
  • Four intensive seasonal sampling campaigns between October 1998 and October 1999 were undertaken at an urban site of Chongju, in which polyurethane foam (PUF) sampler was used to collect particulate- and vapor-phase polycyclic aromatic hydrocarbons (PAHs). The contribution to total (particulate+vapor) PAH concentration by the vapor phase component exceeded the particulate phase contribution by factor of ${\sim}2.6$. Summed concentrations of phenanthrene (30.9%), pyrene (16.6%), naphthalene (11.3%) and fluoranthene (11.0%) account for significant amounts of the vapor-phase, while chrysene (12.5%), benzo[b]fluoranthene (11.6%), indeno[123-cd]pyrene (9.9%), benzo[ghi]perylene (9.5%), benzo[k]fluoranthene (9.4%), pyrene (8.9%), and benzo[a]pyrene (8.3%) are found to be the most common PAH compounds in the particulate phase. The results from application of principal component analysis to particulate-phase PAH data demonstrate that a combination of PAH and $PM_{2.5}$ inorganic data is a more powerful tracer of emission sources than PAH species data alone. Particulate-phase PAH species were found to be associated predominantly with emissions from diesel engine vehicles and incineration.

건설현장의 공사장비에 의한 미세먼지 배출계수 평가 (Assessment of PM Emission Factors Made by Construction Machineries)

  • 이임학;이경빈;김진식;김신도
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.311-318
    • /
    • 2014
  • The goles of this study were that we calculated the difference between the emission factors currently used officially and the emission factors that calculated by atmospheric dispersion modeling results and actual field measurements of dust concentrations and that we investigated how we applied to the emission factors appropriate to the reality in Korea. At the results, we calculated the Business As Usual ambient dust concentration concerning U.S. EPA method emissions, and we thought that the emission reduction efficiency had to be 99.7% if the ambient dust concentration that measured in this study could be satisfied. In other words, U.S. EPA dust emission calculation method is very overestimated than reality, so it is important that our country obtain reliable construction site dust emissions estimation methods by continuous researches.