• Title/Summary/Keyword: atmospheric aerosol

Search Result 741, Processing Time 0.025 seconds

Quality Assurance and Quality Control method for Volatile Organic Compounds measured in the Photochemical Assessment Monitoring Station (광화학측정망에서 측정한 휘발성유기화합물의 정도관리 방법)

  • Shin, Hye-Jung;Kim, Jong-Choon;Kim, Yong-Pyo
    • Particle and aerosol research
    • /
    • v.7 no.1
    • /
    • pp.31-44
    • /
    • 2011
  • The hourly volatile organic compounds(VOCs) concentrations between 2005 and 2008 at Bulgwang photochemical assessment monitoring station were investigated to establish a method for quality assurance and quality control(QA/QC) procedure. Systematic error, erratic error, and random error, which was manifested by outlier and highly fluctuated data, were checked and removed. About 17.3% of the raw data were excluded according to the proposed QA/QC procedure. After QA/QC, relative standard deviation for representing 15 species concentrations decreased from 94.7-548.0% to 63.4-125.8%, implying the QA/QC procedure is proper. For further evaluation about the adequacy of QA/QC procedure, principal components analysis(PCA) was carried out. When the data after QA/QC procedure was used for PCA, the extracted principal components were different from the result from the raw data and could logically explain the major emission sources(gasoline vapor, vehicle exhaust, and solvent usage). The QA/QC procedure based on the concept of errors is inferred to proper to be applied on VOCs. However, an additional QA/QC step considering the relationship between species in the atmosphere needs to be further considered.

Measurement and Control of Hazardous PAHs Reaction Products (위해성 이차 PAHs 성분 측정 및 관리 방안)

  • Lee, Ji Yi;Hong, Ji Hyung;Jung, Chang Hoon;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.111-125
    • /
    • 2013
  • Among the hazardous air pollutions(HAPs), characteristics of secondary organic aerosols are not well understood. In this study, the current state for the measurement and analysis of representative secondary PAHs such as oxy-PAHs and nitro-PAHs are presented with the discussion of their toxicity. Also, further research directions for the secondary PAHs are suggested. It was found that the chemical reaction mechanisms and products of PAHs in the air are poorly identified and their toxicities are not well studied. Moreover ambient concentrations of those secondary PAHs are not well documented. Sampling methodologies of those secondary PAHs are similar with PAHs but the analytical protocols for those secondary PAHs are more complicated than PAHs. Future management directions are suggested along with future research directions.

Measurement of Black Carbon Concentration and Comparison with PM10 and PM2.5 Concentrations monitored at the Chungcheong Province in Korea. (충청지역 블랙카본 농도 측정 및 PM10, PM2.5 농도와의 비교 분석 연구)

  • Cha, Youngbum;Lee, Shihyoung;Lee, Jeonghoon
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • In order to characterize atmospheric aerosols in Chungcheong area, black carbon concentration, which is known to be closely related to global warming, was measured and compared with $PM_{10}$, $PM_{2.5}$ concentrations and various meteorological parameters such as wind velocity and wind direction. Multi Angle Absorption Photometer (MAAP), a filter-based equipment, was used for the black carbon measurement, and the $PM_{10}$, $PM_{2.5}$ concentrations, wind velocity and wind direction were provided by the local monitoring stations. Black carbon concentration was monitored to be high in spring and winter but low in fall. $PM_{10}$ concentration was observed to be high when westerly wind was strong.

Polymerization of Polyethylene Using Bimodal TiCl4/MgCl2/SBA-15/MCM-41

  • Moonyakmoon, Mattanawadee;Klinsrisuk, Sujitra;Poonsawat, Choosak
    • Particle and aerosol research
    • /
    • v.11 no.3
    • /
    • pp.87-92
    • /
    • 2015
  • MCM-41 (Mobil Composition of Matter) and SBA-15 (Santa Barbara Amorphous) were used as a supported catalyst for ethylene polymerization due to their combination of large surface area and wide range of pore size distribution. The morphology of supports was used to control the morphology of the resulting polymer. Different molar ratios of Al/Ti were used for ethylene polymerization at $60^{\circ}C$ under atmospheric pressure. The effect of different mass ratios of MCM-41/SBA-15 and 1-hexene concentration on polymerization activity and polymer properties was investigated. The catalytic activity and the crystallinity reached the highest value at Al/Ti of 480. Upon incorporation of MCM-41 and SBA-15 into $MgCl_2/TiCl_4$ catalyst, the molecular weight and crystallinity of polyethylene were enhanced. The obtained polyethylene showed melting temperature between 130 and $135^{\circ}C$. The polyethylene with replication structure of support and bimodal MWD was expected.

Gas ebullition associated with biological processes in radioactively contaminated reservoirs could lead to airborne radioactive contamination

  • E.A. Pryakhin;Yu.G. Mokrov;A.V. Trapeznikov;N.I. Atamanyuk;S.S. Andreyev;A.A. Peretykin;K. Yu. Mokrov;M.A. Semenov;A.V. Akleyev
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4204-4212
    • /
    • 2023
  • Background: Storage reservoirs of radioactive waste could be the source of atmospheric pollution due to the efflux of aqueous aerosol from their water areas. The main mechanism of formation of aqueous aerosols is the collapse of gas bubbles at the water surface. In this paper, we discuss the potential influence of biological factors on gas ebullition in the water areas of the radioactively contaminated industrial reservoirs R-9 (Lake Karachay) and R-4 (Metlinsky pond) of the Mayak PA. The emission of the released non-dissolved gases captured with gas traps in reservoir R-9 was (88-290) ml/m2 per day (2015) and in reservoir R-4 (270-460) ml/m2 per day (2016). The analysis of gas composition in reservoir R-4 (60% methane, 35% nitrogen, 2.4% oxygen, 1.5% carbon dioxide) confirms their biological origin. It is associated with the processes of organic matter destruction in bottom sediments. The major source of organic matter in bottom sediments is the dying phytoplankton developing in these reservoirs. Conclusion: The obtained results form the basis to set a task to quantify the relationship between the phytoplankton development, gases ebullition and radioactive atmosphere contamination.

Application of MODIS Aerosol Data for Aerosol Type Classification (에어로졸 종류 구분을 위한 MODIS 에어로졸 자료의 적용)

  • Lee, Dong-Ha;Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.6
    • /
    • pp.495-505
    • /
    • 2006
  • In order to classify aerosol type, Aerosol Optical Thickness (AOT) and Fine mode Fraction (FF), which is the optical thickness ratio of small particles$(<1{\mu}m)$ to total particles, data from MODIS (MODerate Imaging Spectraradiometer) aerosol products were analyzed over North-East Asia during one year period of 2005. A study area was in the ocean region of $20^{\circ}N\sim50^{\circ}N$ and $110^{\circ}E\simt50^{\circ}E$. Three main atmospheric aerosols such as dust, sea-salt, and pollution can be classified by using the relationship between AOT and FF. Dust aerosol has frequently observed over the study area with relatively high aerosol loading (AOT>0.3) of large particles (FF<0.65) and its contribution to total AOT in spring was up to 24.0%. Pollution aerosol, which is originated from anthropogenic sources as well as a natural process like biomass burning, has observed in the regime of high FF (>0.65) with wide AOT variation. Average pollution AOT was $0.31{\pm}0.05$ and its contribution to total AOT was 79.8% in summer. Characteristic of sea-salt aerosol was identified with low AOT (<0.3), almost below 0.1, and slightly higher FF than dust and lower FF than pollution. Seasonal analysis results show that maximum AOT $(0.33{\pm}0.11)$ with FF $(0.66{\pm}0.21)$ in spring and minimum AOT $(0.19{\pm}0.05)$, FF $(0.60{\pm}0.14)$ in fall were observed in the study area. Spatial characteristic was that AOT increasing trend is observed as closing to the eastern part of China due to transport of aerosols from China by the prevailing westerlies.

Comparison of ADAM's (Asian Dust Aerosol Model) Results with Observed PM10 Data (황사농도 단기예측모델의 PM10 농도와 실측 PM10 농도의 비교 - 2006년 4월 7~9일 황사 현상에 대해 -)

  • Cho, Changbum;Chun, Youngsin;Ku, Bonyang;Park, Soon-Ung;Lee, Sang-Sam;Chung, Yun-Ang
    • Atmosphere
    • /
    • v.17 no.1
    • /
    • pp.87-99
    • /
    • 2007
  • Simulation results of Asian Dust Aerosol Model (ADAM) for the period of April 7-9, 2006 were analyzed, comparing with observed PM10 data. ADAM simulated around ten times lower than on-site PM10 concentration in the source regions: Zhurihe, Tongliao, Yushe, Dalian and Huimin. As the result of this low concentration, transported amounts of Asian Dust were under-estimated as well. In order to quantify a forecasting accuracy, Bias and RMSE were calculated. Even though remarkably negative Biases and high RMSEs were observed, ADAM simulation had followed well up the time of dust outbreak and a transported path. However, the emission process to generate dust from source regions requires a great enhancement. The PM10 concentration at the surface reached up to $2,300{\mu}gm^{-3}$ at Baeknyoungdo and Seoul (Mt. Gwanak), up to $1,750{\mu}gm^{-3}$ at KGAWO about 18:00 LST in April 8, respectively; however, ADAM did not simulate the same result on its second peak. It is considered that traveling Asian dust might have been lagged over the Korean peninsula by the blocking of surface high pressure. Moreover, the current RDAPS's 30 km grid resolution (which ADAM adopts as the meteorological input data) might not adequately represent small-scale atmospheric motions below planetary boundary layer.

Examining a Vicarious Calibration Method for the TOA Radiance Initialization of KOMPSAT OSMI

  • Sohn, Byung-Ju;Yoo, Sin-Jae;Kim, Yong-Seung;Kim, Do-hyeong
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.4
    • /
    • pp.305-313
    • /
    • 2000
  • A vicarious calibration method was developed for the OSMI sensor calibration. Employing measured aerosol optical thickness by a sunphotometer and a sky radiometer and water leaving radiance by ship measurements as inputs, TOA (top of the atmosphere) radiance at each OSMI band was simulated in conjunction with a radiative transfer model (Rstar5b) by Nakajima and Tanaka (1988). As a case of examining the accuracy of this method, we simulated TOA radiance based on water leaving radiance measured at NASA/MOBY site and aerosol optical thickness estimated nearby at Lanai, and compared simulated results with SeaWiFS-estimated TOA radiances. The difference falls within about $\pm$5%, suggesting that OMSI sensor can be calibrated with the suggested accuracy. In order to apply this method for the OSMI sensor calibration, ground-based sun photometry and ship measurements were carried out off the east coast of Korean peninsula on May 31, 2000. Simulations of TOA radiance by using these measured data as input to the radiative transfer model show that there are substantial differences between simulated and OSMI-estimated radiances. Such a discrepancy appears to be mainly due to the cloud contamination because satellite image indicates optically thin clouds over the experimental area. Nevertheless results suggest that sensor calibration can be achieved within 5% uncertainty range if there are ground-based measurements of aerosol optical thickness, and water leaving radiances under clear-sky and optically thin atmospheric conditions.

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

Identification of PM10 Chemical Characteristics and Sources and Estimation of their Contributions in a Seoul Metropolitan Subway Station (서울시 지하역사에서 PM10의 화학적 특성과 오염원의 확인 및 기여도 추정)

  • Park, Seul-Ba-Sen-Na;Lee, Tae-Jung;Ko, Hyun-Ki;Bae, Sung-Joon;Kim, Shin-Do;Park, Duckshin;Sohn, Jong-Ryeul;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.74-85
    • /
    • 2013
  • Since the underground transportation system is a closed environment, indoor air quality problems may seriously affect many passengers' health. The purpose of this study was to understand $PM_{10}$ characteristics in the underground air environment and further to quantitatively estimate $PM_{10}$ source contributions in a Seoul Metropolitan subway station. The $PM_{10}$ was intensively collected on various filters with $PM_{10}$ aerosol samplers to obtain sufficient samples for its chemical analysis. Sampling was carried out in the M station on the Line-4 from April 21 to 28, July 13 to 21, and October 11 to 19 in the year of 2010 and January 11 to 17 in the year of 2011. The aerosol filter samples were then analyzed for metals, water soluble ions, and carbon components. The 29 chemical species (OC1, OC2, OC3, OC4, CC, PC, EC, Ag, Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Si, Ti, V, Zn, $Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$) were analyzed by using ICP-AES, IC, and TOR after proper pretreatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the $PM_{10}$ sources and then six sources such as biomass burning, outdoor, vehicle, soil and road dust, secondary aerosol, ferrous, and brakewear related source were classified. The contributions rate of their sources in tunnel are 4.0%, 5.8%, 1.6%, 17.9%, 13.8% and 56.9% in order.