• Title/Summary/Keyword: asymmetry ratio

Search Result 199, Processing Time 0.022 seconds

Characteristics Change of Spatial and Temporal Parameters of Gait in Spastic Hemiplegic Patients by Reciprocal Inhibition (상호억제 기법에 의한 경직성 편마비 환자 보행의 공간적, 시간적 특성 변화)

  • Kim Jong-Soon;Lee Hyun-Ok;Ahn So-Youn;Koo Bong-Oh;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.4
    • /
    • pp.59-79
    • /
    • 2004
  • The purpose of this study was to determined the effects of reciprocal inhibition on spatial-temporal gait parameters in spastic hemiplegic patients through GaitRite system. The subjects were consisted 45 patients who had spastic hemiplegia due to stroke. All subjects randomly assigned to 3 group : manual reciprocal inhibition program group(manual group), neuromuscular electrical stimulation group(NMES group) and control group. The manual group received voluntary isometric contraction of pre-tibia muscle. The NMES group received neuromuscular electrical stimulation on tibialis anterior. The control group was not recieved any therapeutic intervention. Before and after experiments, spatial-temporal gait parameters and functional ambulatory profile was measure in all patients. The data of 30 patients who complete experimental course were statistically analysed. The results of this study were as following : 1. The percentage of change of functional ambulatory profile were markedly increased in manual group but statistically non significant(p>.01). 2. The percentage of change of gait velocity and cadence were markedly increased in manual group but statistically non significant(p>.01). 3. Asymmetry ratio of gait elements were more improved in manual group but statistically non significant(p>.01). 4. There were no statistical difference between pre-test and post-test with functional ambulatory profile, gait velocity, cadence and asymmetry ratios in NMES group(p>.01). 5. There were no statistical difference between pre-test and post-test with unctional ambulatory profile, gait velocity, cadence and asymmetry ratios in control group(p>.01). In conclusion, the present results revealed that reciprocal inhibition which produced by voluntary isometric contraction of pre-tibia muscle can be improved spatial-temporal gait parameters including functional ambulatory profile in hemiplegic patients. Therefore, reciprocal inhibition is useful to improve functional activities in hemiplegic patient. Further study should be done to analyze the effects of intervention duration of reciprocal inhibition, appropriate muscle contraction, optimal time to apply the reciprocal inhibition in more long period.

  • PDF

The Age Related Changes of Thickness and Symmetry of Deep Trunk Muscles (노화에 따른 심부 복부근육의 두께 변화와 대칭성 변화)

  • Seo, Dong-Kwon;Lee, Seung-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.3
    • /
    • pp.379-385
    • /
    • 2013
  • PURPOSE: This study is research about deep trunk muscles (DTM) that is important and serve to control the movement of the trunk to provide stability during movement for human. In this study, trying to prove a change of DTM of aging in the ultrasound image. METHODS: We measured via an ultrasound image during rest and contraction of DTM in 42 young and 48 old people, and then we measured the change of thickness and symmetry. RESULTS: Symmetry showed a significant difference only external oblique (EO) in the young(p<.05). In the elderly, it was found that ratio of contraction was greater transverse abdominis than EO. CONCLUSION: I considered it could lead to improvement of activity of daily life by applying intervention for recovery of motor control of TrA for the elderly in clinical practice.

A Heat Transfer Analysis of a Thermally Asymmetric Triangular Fin; Based on Fin Tip Effect (열적 비대칭 삼각 핀의 열전달 해석; 핀 끝 효과에 기준)

  • Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.21-26
    • /
    • 2002
  • The non-dimensional heat loss from a thermally asymmetric triangular fin is investigated as a function of a ratio of upper and lower surface Biot numbers (Bi2/Bi1), the non-dimensional fin length and tip surface Biot number using the two-dimensional separation of variables method. The effect of fin tip surface Biot number on the variation of the non-dimensional temperature along the sloped upper and lower surfaces for the thermally asymmetric condition is presented. The relationship between the non-dimensional fin length and the fin tip surface Biot number for equal amount of heat loss is also discussed as well as the relationship between upper surface Biot number and tip surface Biot number for equal amount of heat loss.

  • PDF

Induction of Apoptotic Cell Death by a Ceramide Analog in PC-3 Prostate Cancer Cells

  • Oh, Ji-Eun;So, Kwang-Sup;Lim, Se-Jin;Kim, Mie-Young
    • Archives of Pharmacal Research
    • /
    • v.29 no.12
    • /
    • pp.1140-1146
    • /
    • 2006
  • Ceramide analogs are potential chemotherapeutic agents. We report that a ceramide analog induces apoptosis in human prostate cancer cells. The ceramide analog induced cell death through an apoptotic mechanism, which was demonstrated by DNA fragmentation, the cleavage of poly ADP ribose polymerase (PARP), and a loss of membrane asymmetry. Treating the cells with ceramide analog resulted in the release of various proapoptotic mitochondrial proteins including cytochrome c and Smac/DIBLO into the cytosol, and a decrease in the mitochondrial membrane potential. In addition, the ceramide analog decreased the phospho-Akt and phospho-Bad levels. The expression of the antiapoptotic Bcl-2 decreased slightly with increasing Bax to Bcl-2 ratio. These results suggest that the ceramide analog induces apoptosis by regulating multiple signaling pathways that involve the mitochondrial pathway.

Variation of Tracer Distribution During the Antarctic Polar Vortex Breakup Shown in ILAS and ILAS-II Data (ILAS와 ILAS-II 자료에서 나타난 남극 와동 붕괴기간의 미량기체 분포변화)

  • Choi, Wookap;Lim, Kyungsoo
    • Atmosphere
    • /
    • v.20 no.3
    • /
    • pp.367-377
    • /
    • 2010
  • Variation of tracer distribution during the vortex-breakup period in the Antarctic region was observed by the data from the Improved Limb Atmospheric Spectrometer (ILAS) and ILAS-II. All four trace species including methane, nitrous oxide, ozone, and water vapor show similar patterns of vertical gradient in spite of different structures of zonal mean mixing ratio. Timings of vortex breakup on each level are estimated by two different methods, and they are compared with zonal standard deviations following the latitude circle of each trace species. Although the tracers have different chemical life times and sink/source, the zonal standard deviation patterns show remarkable similarities. The zonal standard deviation shown here to measure the zonal asymmetry of tracer distribution is believed to diagnose the timing of the Antarctic polar-vortex breakup reasonably well.

Prediction of Stress-strain Behavior for Anisotropic Consolidated Compacted Decomposed Granite Soil (비등방 압밀된 다짐화강풍화토의 응력-변형률 거동 예측)

  • 정진섭;양재혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.86-95
    • /
    • 2003
  • During this study, constant stress ratio tests with previous compression anisotropic stress history are performed on compacted decomposed granite soil sampled at Iksan, Jeonbuk. Yielding points are determined from stress-strain curves. The shape and characteristics of compression anisotropic yield curves is examined. In addition, the measured value of yielding curve and stress-strain behavior is predicted by Yasufuku's anisotropic constitutive model based on non-associated flow rule. The main results are summarized as follows : 1) Shape of yielding curves shows almost ellipse but asymmetry with respect to stress path during previous consolidation stress. 2) Yasufuku's anisotropic constitutive model is suitable in evaluation of yielding curves on anisotropic consolidated decomposed granite soil. 3) The predicted stress-strain curve shows reasonable agreement to measured behaviours.

The Impact of Insurance Contract on Insurance Complaint Ratios through Text Analysis

  • Jeongkwon Seo;Woojin Yang;Hyejin Mun;Chul Ho Lee
    • Asia pacific journal of information systems
    • /
    • v.31 no.4
    • /
    • pp.527-542
    • /
    • 2021
  • The government-driven open data policies are on the rise to protect consumers from misunderstandings and monitor the companies. However, in contract-based industries such as insurance, the contract-inherent characteristics make information asymmetry between consumers and companies. Our paper focuses on insurance contracts where the contingency has high uncertainty of occurrence, and the clauses may incur high costs of reading. Given those contracts, we hypothesized that the contract's clear statement decreases customer dissatisfaction and lowers the number of complaints. To empirically support the claim, we collected customers' complaint documents of insurance companies and insurance contracts from 2005 until 2017. Our econometric models showed that clearer statements and words significantly reduce the complaints after controlling for firm-specific heterogeneity and time-specific heterogeneity. We identify that insurance companies' complaint ratio significantly differ depending on the insurance contract, including specific clauses and words.

A Study on The Improvement of Profile Tilting or Bottom Distortion in HARC (높은 A/R의 콘택 산화막 에칭에서 바닥모양 변형 개선에 관한 연구)

  • Hwang, Won-Tae;Kim, Gli-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.389-395
    • /
    • 2005
  • The etching technology of the high aspect ratio contact(HARC) is necessary at the critical contact processes of semiconductor devices. Etching the $SiO_{2}$ contact hole with the sub-micron design rule in manufacturing VLSI devices, the unexpected phenomenon of 'profile tilting' or 'bottom distortion' is often observed. This makes a short circuit between neighboring contact holes, which causes to drop seriously the device yield. As the aspect ratio of contact holes increases, the high C/F ratio gases, $C_{4}F_{6}$, $C_{4}F_{8}$ and $C_{5}F_{8}$, become widely used in order to minimize the mask layer loss during the etching process. These gases provide abundant fluorocarbon polymer as well as high selectivity to the mask layer, and the polymer with high sticking yield accumulates at the top-wall of the contact hole. During the etch process, many electrons are accumulated around the asymmetric hole mouth to distort the electric field, and this distorts the ion trajectory arriving at the hole bottom. These ions with the distorted trajectory induce the deformation of the hole bottom, which is called 'profile tilting' or 'bottom distortion'. To prevent this phenomenon, three methods are suggested here. 1) Using lower C/F ratio gases, $CF_{4}$ or $C_{3}F_{8}$, the amount of the Polymer at the hole mouth is reduced to minimize the asymmetry of the hole top. 2) The number of the neighboring holes with equal distance is maximized to get the more symmetry of the oxygen distribution around the hole. 3) The dual frequency plasma source is used to release the excessive charge build-up at the hole mouth. From the suggested methods, we have obtained the nearly circular hole bottom, which Implies that the ion trajectory Incident on the hole bottom is symmetry.

Dynamic Characteristics of Composite Thin-Walled Beams with a Chord-Wise Asymmetric Cross-Section: II. Multi-Cell (시위 방향 비대칭 단면의 복합재료 박벽보의 동특성 연구: II. 다중-셀)

  • Kim, Keun-Taek
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.2
    • /
    • pp.51-59
    • /
    • 2019
  • Subsequently, Part I [1], which was about the single-cell model, a composite thin-walled beam with a multi-cell of chord-wise asymmetric cross-section, was selected in this study. Moreover, the theoretical dynamic characteristics of the model were analyzed. For this analysis, mathematical modeling was performed by considering the warping restraint effects, transverse shear effects, taper ratio and cross-section ratio. Similar to part I, the mass, stiffness coefficients and Eigen frequencies of the multi-cell section considered were investigated. In particular, the comparison between the multi-cell and single-cell sections and the effects of the cross-section ratio and taper ratio of the model on the Eigen frequencies were analyzed. However, the results compared when the asymmetry of the section was considered and warping function were not corrected.

qEEG Measures of Attentional and Memory Network Functions in Medical Students: Novel Targets for Pharmacopuncture to Improve Cognition and Academic Performance

  • Gorantla, Vasavi R.;Bond, Vernon Jr.;Dorsey, James;Tedesco, Sarah;Kaur, Tanisha;Simpson, Matthew;Pemminati, Sudhakar;Millis, Richard M.
    • Journal of Pharmacopuncture
    • /
    • v.22 no.3
    • /
    • pp.166-170
    • /
    • 2019
  • Objectives: Attentional and memory functions are important aspects of neural plasticity that, theoretically, should be amenable to pharmacopuncture treatments. A previous study from our laboratory suggested that quantitative electroencephalographic (qEEG) measurements of theta/beta ratio (TBR), an index of attentional control, may be indicative of academic performance in a first-semester medical school course. The present study expands our prior report by extracting and analyzing data on frontal theta and beta asymmetries. We test the hypothesis that the amount of frontal theta and beta asymmetries (fTA, fBA), are correlated with TBR and academic performance, thereby providing novel targets for pharmacopuncture treatments to improve cognitive performance. Methods: Ten healthy male volunteers were subjected to 5-10 min of qEEG measurements under eyes-closed conditions. The qEEG measurements were performed 3 days before each of first two block examinations in anatomy-physiology, separated by five weeks. Amplitudes of the theta and beta waveforms, expressed in ${\mu}V$, were used to compute TBR, fTA and fBA. Significance of changes in theta and beta EEG wave amplitude was assessed by ANOVA with post-hoc t-testing. Correlations between TBR, fTA, fBA and the raw examination scores were evaluated by Pearson's product-moment coefficients and linear regression analysis. Results: fTA and fBA were found to be negatively correlated with TBR (P<0.03, P<0.05, respectively) and were positively correlated with the second examination score (P<0.03, P=0.1, respectively). Conclusion: Smaller fTA and fBA were associated with lower academic performance in the second of two first-semester medical school anatomy-physiology block examination. Future studies should determine whether these qEEG metrics are useful for monitoring changes associated with the brain's cognitive adaptations to academic challenges, for predicting academic performance and for targeting phamacopuncture treatments to improve cognitive performance.