• 제목/요약/키워드: aspheric

검색결과 286건 처리시간 0.029초

Effect of the Liquid Density Difference on Interface Shape of Double-Liquid Lens

  • Kong, Meimei;Zhu, Lingfeng;Chen, Dan;Liang, Zhongcheng;Zhao, Rui;Xu, Enming
    • Journal of the Optical Society of Korea
    • /
    • 제20권3호
    • /
    • pp.427-430
    • /
    • 2016
  • The effect of the liquid density difference on interface shape of a double-liquid lens is analyzed in detail. The expressions of interface shape of two liquids with liquid density difference are analyzed and fitted with “even asphere”. The imaging analysis of the aspheric interface shape of a double-liquid lens is presented. The results show that the density difference of two liquids can cause the interface to be an aspheric surface, which can improve the image quality of a double-liquid lens. The result provides a new selection for the related further research and a wider application field for liquid lenses.

A Study on Molding Condition of Aspheric Glass Lenses Using Design of Experiments Slow Cooling Condition

  • Cha, Du-Hwan;Lee, June-Key;Kim, Hyun-Uk;Kim, Sang-Suk;Kim, Hye-Jeong;Park, Yong-Pil;Jeong, Jong-Guy;Kim, Jeong-Ho
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.464-464
    • /
    • 2008
  • This study investigated the slow cooling conditions in the molding of aspheric glass lens using the design of experiment (DOE). The optimization of the slow cooling conditions with respect to the form accuracy (PV) of the molded lens were ascertained by employing full factorial design. As a result of the analysis of variance (ANOVA) and P-value (significance level), it was verified that slow cooling rate represent the most significant operative variables that affect the corresponding response variable. In the optimum condition, the molded lens show 82% of transcription ratio.

  • PDF

DOE를 적용한 비구면 Glass 렌즈 성형용 초경합금(WC) 코어 연삭가공 최적화 (Optimal Grinding Condition of Tungsten Carbide(WC) for Aspheric Glass Lens Using DOE)

  • 김현욱;정상화;안준형;차두환;이동길;김상석;김혜정;김정호
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.41-45
    • /
    • 2006
  • In recent years, the demands of the aspheric glass lenses increase since it is difficult to obtain the desirable performance in the plastic lens. Glass lens is manufactured by the forming with high precision mold core. This paper presents the analysis of optimal grinding condition of tungsten carbide(WC, Co 0.5%) using design of experiments(DOE). The process parameters are turbin spindle, work spindle, feedrate and depth of cut. The experiments results are evaluated by MINITAB software.

  • PDF

Optical Performance Degradation Effects by Fabrication Errors of Circular-type Computer Generated Holograms

  • Kim, Young-Gwang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1657-1662
    • /
    • 2018
  • A null test method which relies on a computer generated hologram (CGH) is widely used to measure a large aspheric surface. For precise measurements of the surface shape of an aspheric optics, the CGH must precisely generate a wavefront that can fit on the ideal surface shape of the aspheric optics. If fabrication errors arise in the CGH, an unwanted wavefront will be generated and the measuring result will lack trustworthiness. Thus far, there has been limited research on wavefronts generated by CGH using only linear-type binary grating models. In this study, a theoretical error model of a circular-type zone plate, the most commonly used types for CGH patterns, is suggested. The proposed error model is checked by simulations and experiments.

CONSIDERATION OF IR PHASE-SHIFTING INTERFEROMETRIC SYSTEM FOR TESTING ASTRONOMICAL ASPHERIC MIRROR IN CHINA

  • ZHOU WENGE;CUI XIANGQUN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.403-404
    • /
    • 1996
  • This paper describes a plan of a new IR phace-shfting interferometric system for testing astronomical aspheric mirror which has big departure from the best fit reference sphere during fine grinding. In this experimental system, some new technology will be adopted. The accuracy of system can reach $\lambda$/40($\lambda$=10.6${\mu}m$)

  • PDF

비구면렌즈 모델링 및 CAM적용에 관한 연구

  • 김수용;김민주;이승수;박재현;서용권;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.240-240
    • /
    • 2004
  • 본 논문에서는 광학 기기 전반에 사용되고 있는 비구면 렌즈(aspheric lens)의 모델링과 제작 및 검증에 관한 연구를 수행하였다. 비구면 렌즈는 볼록렌즈, 오목렌즈와 달리 비구면을 사용함으로써, 사물의 원근에 관계없이 하나의 초점에 상을 맺을 수 있다. 그러나 이에 대한 모델링 정보는 공개되지 야고 있다. 따라서 본 연구에서는 다음의 식을 오일러 법(Euler method)을 적용하여 비구면 렌즈의 기하학적 형상을 모델링하였다.(중략)

  • PDF

초정밀 단일점 다이아몬드 터닝을 이용한 비구면 금속 부반사경 가공 (Ultra-precision single point diamond turning (SPDT) on an aspheric metal secondary mirror)

  • Kim, E. D.;H. S. Yang;Kim, G-H.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.96-97
    • /
    • 2001
  • A 110 mm diameter aspheric metal secondary mirror for a test model of an earth observation satellite camera was fabricated by ultra-precision single point diamond turning (SPDT) . Without a conventional polishing process, the surface texture of R$\sub$a/=2.8 nm, and the form error of R$\sub$a/=0.05 λ has been stably achieved In a laboratory condition. (omitted)

  • PDF