• 제목/요약/키워드: artificial ground motion

검색결과 75건 처리시간 0.027초

Seismic behavior of three dimensional concrete rectangular containers including sloshing effects

  • Mirzabozorg, H.;Hariri-Ardebili, M.A.;Nateghi A., R.
    • Coupled systems mechanics
    • /
    • 제1권1호
    • /
    • pp.79-98
    • /
    • 2012
  • In the present paper, the three-dimensional model of a typical rectangular concrete tank is excited using an artificial and a natural three components earthquake ground motion and the staggered displacement method is utilized for solving the coupled problem of the tank-contained liquid system in time domain. In the proposed method, surface sloshing of the liquid is taken into account in addition to the impulsive term and the appropriate damping values are applied on both of them. The resulted responses are compared with those obtained from the ABAQUS finite element software. It is found that the convective term affects responses extensively and must be considered in seismic design/safety assessment of storage tanks. In addition, the utilized method for solving the coupled problem is stable during the conducted general dynamic analyses and is able to capture the expected phenomena.

진동 제어 장치를 포함한 구조물의 지진 응답 예측을 위한 순환신경망의 하이퍼파라미터 연구 (Research on Hyperparameter of RNN for Seismic Response Prediction of a Structure With Vibration Control System)

  • 김현수;박광섭
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.51-58
    • /
    • 2020
  • Recently, deep learning that is the most popular and effective class of machine learning algorithms is widely applied to various industrial areas. A number of research on various topics about structural engineering was performed by using artificial neural networks, such as structural design optimization, vibration control and system identification etc. When nonlinear semi-active structural control devices are applied to building structure, a lot of computational effort is required to predict dynamic structural responses of finite element method (FEM) model for development of control algorithm. To solve this problem, an artificial neural network model was developed in this study. Among various deep learning algorithms, a recurrent neural network (RNN) was used to make the time history response prediction model. An RNN can retain state from one iteration to the next by using its own output as input for the next step. An eleven-story building structure with semi-active tuned mass damper (TMD) was used as an example structure. The semi-active TMD was composed of magnetorheological damper. Five historical earthquakes and five artificial ground motions were used as ground excitations for training of an RNN model. Another artificial ground motion that was not used for training was used for verification of the developed RNN model. Parametric studies on various hyper-parameters including number of hidden layers, sequence length, number of LSTM cells, etc. After appropriate training iteration of the RNN model with proper hyper-parameters, the RNN model for prediction of seismic responses of the building structure with semi-active TMD was developed. The developed RNN model can effectively provide very accurate seismic responses compared to the FEM model.

이동하면서 측정할 수 있는 시간영역전자탐사 시스템 개발을 위한 센서흔들림유도잡음 제거 연구 (A Study on Sensor Motion-Induced Noise Reduction for Developing a Moving Transient Electromagnetic System)

  • 황학수;이상규
    • 자원환경지질
    • /
    • 제31권1호
    • /
    • pp.53-57
    • /
    • 1998
  • Transient electromagnetic (TEM) method is also affected by cultural and natural electromagnetic (EM) noises, since it uses part of the broadband ($10^{-2}$ to $10^5Hz$) spectrum. Especially, predominant EM noise which affects a moving transmitter-receiver TEM system is sensor motion-induced noise. This noise is caused by the sensor motion in the earth magnetic field. The technique for reducing the sensor motion-induced EM noise presented in this paper is based on Halverson stacking. This Halverson stacking is generally used in a time-domain induced polarisation (IP) system to reject DC offset and linear drift. According to spectrum analysis of the vertical component of sensor motion-induced noise, the frequency range affected by the motion of an EM sensor is less than about 700 Hz in this study. With the decrease of the frequency, the spectral power caused by the motion of a sensor increases. For example, at the frequency of 200 Hz, the spectral power of the sensor motion-induced noise is $-90dBVrms^2$ while the spectral power of the EM noise measured with a fixed sensor on the ground is $-105dBVrms^2$, and at the frequency of 100 Hz, the spectral power of the sensor motion-induced noise is $-70dBVrms^2$ while the spectral power of the EM noise measured with a fixed sensor on the ground is $-105dBVrms^2$. With applying Halverson stacking to an artificial noise transient generated by adding a noise-free transient to sensor motion-induced noise measured without pulsing, it is shown that the filtered transient is nearly consistent with the noise-free transient within a delay time of $0.5{{\mu}sec}$. The inversion obtained from this filtered transient is in accord with the true model with an error of 5%.

  • PDF

Seismic Capacity Required for the Safety Limit Design of High-rise RC Buildings under Long-period Ground Motions in Osaka, JAPAN and its Estimation Based on the Equivalent Linearization Method

  • Sanada, Yasushi;Yoshida, Hiroki;Awano, Masayuki
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.315-323
    • /
    • 2020
  • In June 2016, the Ministry of Land, Infrastructure, Transport and Tourism (MLIT) in Japan delivered countermeasures against long-period ground motions caused by strong earthquakes along the Nankai trough. However, the countermeasures do not cover high-rise buildings equal to or shorter than 60 m in height, which do not require earthquake response analyses in the seismic design. Hence, in the present study, earthquake response analyses for such high-rise reinforced concrete (RC) buildings were performed under artificial ground motions assumed in the OS1 and OS2 regions to determine the base shear coefficients that satisfy a given safety demand. Furthermore, the results from the earthquake response analyses were estimated by the authors' proposed method based on the equivalent linearization method, showing good agreement and inspiring suggestions for more accurate and simplified estimations.

중층계류식 인공해저시스템의 파랑중 운동특성에 관한 실험적 연구 (An Experimental Investigation on the Hydrodynamic Characteristics of Submerged Artificial Seabed System in Regular Waves)

  • 윤상준;양찬규;김현주;김헌태
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제5권2호
    • /
    • pp.19-27
    • /
    • 2002
  • 본 연구는 입체적 어장 개발을 위해 수산자원 증대의 토대가 되는 해조장의 확대와 생태계의 고밀도·고효율화를 위한 기초적 연구로 수평판형 중층계류식 인공해저시스템의 파랑응답특성에 관한 실험적 연구를 수행하였다. 실험은 2차원 수조에서 다른 두 가지 모형의 수평판을 세 가지 다른 수심에 각각 고정 혹은 계류시켜 실시하였다. 실험에서 모형 고정시의 작용유체력 특성과 모형 계류시의 파랑응답 및 계류력 특성을 살펴보았으며, 또 각 조건에서 모형의 파랑제어특성을 검토하였다.

  • PDF

한국의 지반거동을 고려한 교량과 송전철탑의 지진취약도 분석 (Seismic Fragilities of Bridges and Transmission Towers Considering Recorded Ground Motions in South Korea)

  • 박효상;응웬 두이-두안;이태형
    • 한국지진공학회논문집
    • /
    • 제20권7_spc호
    • /
    • pp.435-441
    • /
    • 2016
  • The Korean peninsula has known as a minor-to-moderate seismic region. However, some recent studies had shown that the maximum possible earthquake magnitude in the region is approximately 6.3-6.5. Therefore, a seismic vulnerability assessment of the existing infrastructures considering ground motions in Korea is necessary. In this study, we developed seismic fragility curves for a continuous steel box girder bridge and two typical transmission towers, in which a set of seven artificial and natural ground motions recorded in South Korea is used. A finite element simulation framework, OpenSees, is utilized to perform nonlinear time history analyses of the bridge and a commercial software, SAP2000, is used to perform time history analyses of the transmission towers. The fragility curves based on Korean ground motions were then compared with the fragility curves generated using worldwide ground motions to evaluate the effect of the two ground motion groups on the seismic fragility curves of the structures. The results show that both non-isolated and base-isolated bridges are less vulnerable to the Korean ground motions than to worldwide earthquakes. Similarly to the bridge case, the transmission towers are safer during Korean motions than that under worldwide earthquakes in terms of fragility functions.

Maximum damage prediction for regular reinforced concrete frames under consecutive earthquakes

  • Amiri, Gholamreza Ghodrati;Rajabi, Elham
    • Earthquakes and Structures
    • /
    • 제14권2호
    • /
    • pp.129-142
    • /
    • 2018
  • The current paper introduces a new approach for development of damage index to obtain the maximum damage in the reinforced concrete frames caused by as-recorded single and consecutive earthquakes. To do so, two sets of strong ground motions are selected based on maximum and approximately maximum peak ground acceleration (PGA) from "PEER" and "USGS" centers. Consecutive earthquakes in the first and second groups, not only occurred in similar directions and same stations, but also their real time gaps between successive shocks are less than 10 minutes and 10 days, respectively. In the following, a suite of six concrete moment resisting frames, including 3, 5, 7, 10, 12 and 15 stories, are designed in OpenSees software and analyzed for more than 850 times under two groups of as-recorded strong ground motion records with/without seismic sequences phenomena. The idealized multilayer artificial neural networks, with the least value of Mean Square Error (MSE) and maximum value of regression (R) between outputs and targets were then employed to generate the empirical charts and several correction equations for design utilization. To investigate the effectiveness of the proposed damage index, calibration of the new approach to existing real data (the result of Park-Ang damage index 1985), were conducted. The obtained results show good precision of the developed ANNs-based model in predicting the maximum damage of regular reinforced concrete frames.

Effect of ground motion characteristics on the pure friction isolation system

  • Nanda, Radhikesh P.;Shrikhande, Manish;Agarwal, Pankaj
    • Earthquakes and Structures
    • /
    • 제3권2호
    • /
    • pp.169-180
    • /
    • 2012
  • The performance of pure friction isolation system with respect to the frequency bandwidth of excitation and the predominant frequency is investigated. A set of earthquake ground motions (artificial as well as recorded [with different combinations of magnitude-distance and local site geology]) is considered for investigating effectiveness of pure friction isolators. The results indicate the performance of pure friction base isolated system does not only depend upon coefficient of friction and mass ratio but the stick-slip behaviour depends upon the frequency content of the excitation as well. Slippage prevails if the excitation frequency lies in a suitable frequency range. This range widens with increasing mass ratio. For larger mass ratios, the sliding effect is more pronounced and the maximum acceleration response is further reduced in the neighbourhood of frequency ratio (${\omega}/{\omega}_n$) of unity. The pure friction isolation system is effective in the case of broadband excitations only and that too, in the acceleration sensitive range of periods. The pure friction system is not effective for protection against narrow band motions for which the system response is quasi-periodic.

지진특성에 따른 MR 감쇠기가 설치된 단자유도 구조물의 등가감쇠비 (Equivalent damping ratio based on earthquake characteristics of a SDOF structure with an MR damper)

  • 문병욱;박지훈;이성경;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.459-464
    • /
    • 2007
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally, response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

  • PDF

MR 감쇠기가 설치된 단자유도 구조물의 지진응답에 기초한 등가감쇠비 (Equivalent damping ratio based on the earthquake response of a SDOF structure with a MR damper)

  • 박지훈;문병욱;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.879-885
    • /
    • 2006
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally, response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

  • PDF