• 제목/요약/키워드: artificial dye

검색결과 37건 처리시간 0.028초

Modified Gas Tracer Method 를 이용한 하천 재폭기계수의 산정 (Determination of Stream Reaeration Coefficient Using Modified Gas Tracer Method)

  • 조영준
    • 한국농공학회지
    • /
    • 제41권4호
    • /
    • pp.57-65
    • /
    • 1999
  • A modified gas tracer method was used to obtain reaeration coefficient from an artificial channel and a reach of Bokha stream, Ichon city. Propane was used as the tracer gas and Rhodamine-B dye as a dispersion and dulution tracer. Concentrations of propane in water sample were measured using a gas chromatograph and concentrationsof dye using UV-Spectrophotometer. To compare measured values with predicted values,commonly used 14 equations were selected . Results of this study suggested that the modified gas tracer method is a potentially useful procedure for th edetermination of reaeration cofficients. However, estimated reaeration coefficients from predictive equations were significantly different from that of this study. Therefore, when using predictive equations, careful selection of equation with consideration for hydraulic characteristics such as flow depth and average velocity, or use of newly derived predictive equation which is adequate for questioned stream would be needed.

  • PDF

상아질 접착제의 상아세관 밀봉지속효과에 관한 연구 (A STUDY OF THE DURABILITY OF DENTINAL TUBULE SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 김의성;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.180-193
    • /
    • 1994
  • The purpose of this study was to observe the sealing ability and durability of All-Bond 2, Gluma Bonding System, Scotch bond 2 and Superbond D-liner which are dentin bonding agents used as desensitizing agents. The durability of the sealing ability of the materials were compared after 0, 140, 420, 840 tooth brushing strokes. 120 extracted teeth were divided into 5 groups and the agents were applied to the exposed dentin. No agents was applied on group I, the control group. Each specimen went through thermocycling from $5^{\circ}$ to $55^{\circ}C$, 200 times. Each group was devide into 4 subgroups and artificial tooth brushing strokes were done for 0, 140, 420, 840 times. Finally the specimens were stored in 0.5 % methylene blue solution for 24 hours in a incubator set at $37^{\circ}C$. The tooth were sectioned perpendicular to the long axis and the dye penetration ratio to the pulp was measured. The following results were obtained. 1. All four dentin bonding agents initially showed excellent sealing ability. 2. All-bond 2, Gluma Bonding System and Superbond D-liner showed durability of dentinal tubule sealing effect after 840 strokes(6-week) artificial tooth brushing. 3. Scotchbond 2 showed a significant decrease in sealing ability after 420 strokes(3-week) artificial tooth brushing. (P<0.05).

  • PDF

Dyeproperties of Artificial silk/paper mulberry mixed fabrics using Dendropanax morbifera Lev.

  • Jeon, Ji-Eun;Jeon, Jin-Hwa;Lee, Sang-A;Choi, Jae-Hong;Park, Young-Mi
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2011년도 제45차 학술발표회
    • /
    • pp.33-33
    • /
    • 2011
  • Artificial silk that called "Ponggi (Gyeongsangbukdo, Korea) In-Gyeun" in Korea is entirely viscose rayon of which made main component refined larches and cotton linter. It also is natural fabrics with light weight, cool texture, free from the body and well ventilation property, so, feel good touch during the wearing. In addition, it often used as summer cloth and bedding because it has good absorbancy to perspiration and antistatic. The "Hanji", made of paper mulberry, is known as useful material for human. In this research focused on dyeability of Artificial silk/paper mulberry mixed fabrics using Dendropanax morbifera Lev.(called as "Hwangchil") Especially, the results were in comparison to the dyeing properties of Hwangchil with liquid/solid fermentation or not. As the results, The ${\Delta}E$ difference was dominated when the fabric dyed with fermentation by solid state at $60^{\circ}C$. And it was confirmed that the pH of fermented dye had an important influence in the coloration.

  • PDF

레이저 형광과 광활성제를 이용한 초기 우식증의 진단 (DIAGNOSIS OF EARLY CARIES WITH DYE-ENHANCED LASER FLUORESCENCE)

  • 이상호;한국재;이창섭
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.1-9
    • /
    • 2003
  • 초기 우식병소와 건전한 치질은 광학적 특성이 다르다는 사실에 근거하여 치과 치료용으로 개발된 가시광선 영역의 레이저의 형광현상과 광활성재를 이용하여 우식 치질과 건전한 치질간의 광학적 특성의 차이를 색조의 차이로 유도 전환함으로써 초기 우식 병소를 조기에 시각적으로 탐지하여 진단하는 방법을 개발하는데 본 연구의 목적이 있다. 소의 치아를 이용하여 여러 단계 깊이의 인공우식병소를 유발하고 우식병소의 표면에서 아르곤 레이저를 조사하여 건전 치질과 우식 치질 사이의 반사된 형광강도의 차이를 컴퓨터 영상분석프로그램을 통해 측정하였다. 또한 광활성재를 병소의 표면에 도포하여 형광현상의 색조대비 증진효과를 평가하였다. 실제 조직학적 병소와 레이저 형광법 사이의 상관관계 분석 및 회귀 분석을 통하여 다음과 같은 결과를 얻었다. 레이저 형광법에 의한 우식 치질은 건전 치질보다 어둡게, 그리고 광활성재를 도포한후 레이저 형광법으로 관찰한 우식 병소는 건전 치질 보다 밝게 관찰 되었으며 광활성재를 이용한 레이저 형광법이 탈회의 초기단계에서는 레이저 형광법에 비해 진단학적 민감도가 컸다.

  • PDF

Thin-Layer Chromatography에 의한 시판 알사탕류의 착색료에 관한 고찰 (Study on the Detection of Artificial Dyes in the Commercial Drops by Use of Thin-Layer Chromatography)

  • 구성회;우세홍;한식일;이성호
    • 한국환경보건학회지
    • /
    • 제1권1호
    • /
    • pp.14-17
    • /
    • 1974
  • A study was carried out to detect of illegal artificial dyes, and to confirm the used rate of illegal dyes in the production process of commercial drops (candy), from Dec. 10, 1972 to Feb. 10, 1973. In this study, it was used thin layer chromatography, the samples were divided into two groups, group A of inscribed trade name and group B of not inscribed trade name. To contrast with group A and group B, 100 samples were randomly collected in the market places, 50 samples from group A and 50 samples from group B. The following conclusions were obtained: 1) used rate of illegal dyes were 2% of group A and 9% of group B. 2) used rate of illegal dyes were 2% of red, 2% of yellow, 1% of violet and 6% of green, not in blue. 3) used rate of illegal dyes 3% of Rhodamine B, 3% of Auramine and 6% of Light green S.F. Yellowish. 4) Out of 20 cases those used mixed dyes, only one case was confirmed as two illegal dyes, and 4 cases were used one illegal dye.

  • PDF

레이저 형광법을 이용한 인접면 우식증의 진단 (DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE)

  • 설재헌;오유향;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.236-246
    • /
    • 2004
  • 레이저 형광법을 이용하여 초기 인접면 우식증을 탐지할 수 있는지의 여부와 그 탐지 감도를 평가하여 인접면 우식증의 진단에 활용가능한지의 여부를 규명하기 위하여 사람의 치아를 사용하여 다양한 깊이의 인공우식병소를 유발시키고 이를 가시광선 투과법에 의한 시진, 교익 방사선사진 촬영, 레이저 형광법, 광활성 염료를 이용한 레이저 형광법 등으로 관찰하여 검사법 간의 일치도, 상관관계, 병소 깊이에 따른 광밀도 등을 분석하여 다음과 같은 결과를 얻었다. 1. 탈회시간과 각 검사법들과 일치도 검사에서 시진의 경우 tau-c 값이 0.08로 탈회시간에 따른 시진의 검사 수치가 일치하지 않았으나 교익 방사선사진, 레이저 형광법, 광활성 염료를 이용한 레이저 형광법의 tau-c 값은 각각 0.60, 0.48, 0,64로 일치하는 것으로 나타났다. 2. 탈회시간에 따른 병소깊이와 각 검사법 간의 상관관계는 광활성 염료를 이용한 레이저 형광법$({\gamma}=0.51)$, 레이저 형광 법$({\gamma}=0.43)$, 교익 방사선사진$({\gamma}=0.35)$, 시진$({\gamma}=0.33)$ 순으로 높았으며 광활성 염료를 이용한 레이저 형광법과 레이저 형광법은 탈회 시간과 상관관계가 있었다(P<0.05). 3. 교익 방사선사진을 기준 검사법으로 한 레이저 형광법과 광활성 염료를 이용한 레이저 형광법의 진단학적 민감도는 각각 67%, 100%였으며 특이도는 57%, 11%로 민감도에 비해 상대적으로 낮게 나타났다. 4. 병소의 깊이에 따른 병소 표면에서의 건전 치질과 우식 치질 사이의 광밀도의 차이(DFR)는 광활성 염료를 이용한 레이저 형광법이 레이저 형광법에 비해 크게 나타났으며(P<0.05) 병소 깊이의 변화에 따른 광밀도 변화는 레이저 형광법의 경우 유의한 변화를 보이는데 반해 광활성 염료를 이용한 레이저 형광법에서는 변화를 보이지 않았다. 이상의 결과를 종합하면 초기 인접면 우식증의 진단에 있어 레이저 형광법과 광활성 염료를 이용한 레이저 형광법은 교익 방사선사진에 뒤지지 않은 진단능을 가지고 있으나 우식 병소의 정성적인 분석뿐 아니라 정량적 분석이 가능한지의 여부는 향후 더 많은 연구가 필요하리라 사료된다.

  • PDF

Proteomic Analysis of Bovine Pregnancy-specific Serum Proteins by 2D Fluorescence Difference Gel Electrophoresis

  • Lee, Jae Eun;Lee, Jae Young;Kim, Hong Rye;Shin, Hyun Young;Lin, Tao;Jin, Dong Il
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권6호
    • /
    • pp.788-795
    • /
    • 2015
  • Two dimensional-fluorescence difference gel electrophoresis (2D DIGE) is an emerging technique for comparative proteomics, which improves the reproducibility and reliability of differential protein expression analysis between samples. The purpose of this study was to investigate bovine pregnancy-specific proteins in the proteome between bovine pregnant and non-pregnant serum using DIGE technique. Serums of 2 pregnant Holstein dairy cattle at day 21 after artificial insemination and those of 2 non-pregnant were used in this study. The pre-electrophoretic labeling of pregnant and non-pregnant serum proteins were mixed with Cy3 and Cy5 fluorescent dyes, respectively, and an internal standard was labeled with Cy2. Labeled proteins with Cy2, Cy3, and Cy5 were separated together in a single gel, and then were detected by fluorescence image analyzer. The 2D DIGE method using fluorescence CyDye DIGE flour had higher sensitivity than conventional 2D gel electrophoresis, and showed reproducible results. Approximately 1,500 protein spots were detected by 2D DIGE. Several proteins showed a more than 1.5-fold up and down regulation between non-pregnant and pregnant serum proteins. The differentially expressed proteins were identified by MALDI-TOF mass spectrometer. A total 16 protein spots were detected to regulate differentially in the pregnant serum, among which 7 spots were up-regulated proteins such as conglutinin precursor, modified bovine fibrinogen and IgG1, and 6 spots were down-regulated proteins such as hemoglobin, complement component 3, bovine fibrinogen and IgG2a three spots were not identified. The identified proteins demonstrate that early pregnant bovine serum may have several pregnancy-specific proteins, and these could be a valuable information for the development of pregnancy-diagnostic markers in early pregnancy bovine serum.

Ferric Oxinate를 標職物質로 사용한 人工汚染布의 洗滌特性 (Characteristics of Artificially Soiled Fabrics Containing Ferric Oxinate as a Tracer)

  • Ahn, Kyung Cho;Kim, Sung Reon
    • 한국염색가공학회지
    • /
    • 제8권1호
    • /
    • pp.83-89
    • /
    • 1996
  • Carbon black has been used as a particulate soil to prepare artificial soiled fabrics for detergent study but it has two major defects. The one is the difficulty of quantitative analysis of carbon black for evaluate the detergency, the other is that there is no reliable correlation between the removal of carbon black and oily soil which is the major component of natural soil. In this study ferric oxinate was used as a particulate soil since it is in black color and can be soiled on fabric by suspension in water or by solution in chloroform and it is easily analysed quantitatively by extracting it from soiled fabric with chloroform to get correct value of soil removal. The characteristics of soil removal of ferric oxinate were compared with that of carbon black and Sudan black, an oil soluble dye, which had been proved that it's detergency correlated with that of oily soil The soil removal of ferric oxinate and Sudan black estimated from quantitative analysis and from K/S value were in good agreement whereas the result calculated by simple reflectance was consistently low. The soil removal of ferric oxinate was exceeded from that of carbon black without regard to surfactants, Triton and Las, but the effect of washing conditions such as temperature and washing time on soil removal of both soils with different suffactants showed no considerable difference. Though the soil removal of Sudan black was little effected by the conditions, the soil removal in Triton exceeded considerably that of in Las, which is the characteristic of oily soil. Thus the soil removal of Sudan black was in good agreement with ferric oxinate in Triton, a non-ionic surfactant, and with carbon black in Las, an artionic surfactant. We concluded that ferric oxinate is a more realistic model particulate soil for artificial soiled cotton fabric washed with non-ionic surfactant than carbon black.

  • PDF

Evaluation of Marginal and Internal Integrity of Modified Resin-Bonded Fixed Partial Dentures: An In Vitro Study

  • Ahn, Sung-Hyeon;Choi, Jae-Won;Jeon, Yong-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • 제10권1호
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the microleakage of various types of resin-bonded fixed partial dentures (RBFPDs) after artificial aging. Materials and Methods: Forty models with missing first molar were fabricated using artificial resin teeth and were divided into four groups: Group A, conventional RBFPDs design; Group B, modified RBFPDs design; Group C, assembled 3-piece RBFPDs design; and Group D, assembled 3-piece RBFPDs with different occlusal rest positions. Half of the specimens underwent chewing simulation process (240,000 cycles, 50 N load, 1.7 Hz) and thermocycling (temperatures $5^{\circ}C{\sim}55^{\circ}C$, dwelling time 30 seconds) and the remaining 20 specimens didn't receive any treatment. All the specimens were immersed in 2% methylene blue solution for 24 hours to evaluate microleakage, and were sectioned at the middle part of abutment teeth. To evaluate the microleaskage, a dye penetration was calculated. Result: With artificial aging, cyclic loading and thermocycling, a 3-piece RBPFD and a 2-piece RBPFD using original tooth undercuts have significantly lower microleakge (P<0.05) compared to the conventional design of RBPFD and modified RBPFD. Conclusion: Within the limit of this experiment, the assembled RBFPDs exhibited a smaller microleakage than the conventional RBFPDs, implying that the assembled RBFPDs can be more effective for reducing the dislodgement of the RBFPDs.

접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출 (SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT)

  • 박주식;이석종;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF