• Title/Summary/Keyword: arson

Search Result 63, Processing Time 0.025 seconds

Implementation of Emergency Evacuation Support System in Panic-type Disaster (돌발성 재해에 대비한 긴급 피난 지원 시스템의 구현)

  • Hwang, Jun-Su;Choi, Young-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1269-1276
    • /
    • 2016
  • Recently, natural disasters including earthquakes, tsunamis, floods, and snowstorms, in addition to disasters of human origin such as arson, and acts of terror, have caused numerous injuries and fatalities around the world. During such disasters, victims need to obtain information such as the exact location of the disaster and appropriate evacuation routes in order to relocate to safe areas. In this study, We propose the algorithm for Emergency Rescue Evacuation Support System(ERESS). In case a emergency disaster occurs, ERESS is possible to detect it quickly using through the movement of people. The mobile terminal analyzes behavior and location of indoor pedestrian. And it sends the result to the server. The server determines whether an emergency situation occurred or not based on the received transmission information. When an emergency situation occurs, the server will notify it to the mobile terminal. Then, indoor pedestrian conduct emergency evacuation using mobile terminal.

Crime Patterns of CBD in Cheongiu City (청주시 도심의 범죄 특성)

  • 고준호
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.3
    • /
    • pp.329-341
    • /
    • 2001
  • The purpose of this study focused on the distribution of crimes in Cheongju City. This study emphasized the characteristics of place and spatial pattern of crime in Central Business District(CBD). The crime core areas were delineated and explained through land-use based on fieldwork and GIS analysis For this aim. the police crime data of Cheongju Dongbu(east). Seobu(west) for 1998 were collected In which 3.909 indictable or similar offenses were reported. In this study, Included climes are murder. rape, robbery. arson, theft, burglary, assault and vandalism. Because theme crimes are related with site-specific crime. As a result. land-use patterns are often related to specific type of offenses. The climes in Cheongju City were concentrated in the CBD Most crimes were assaults and thefts Crime areas can be classified by the age of the offender Around Chungang and Pungmul Market in the CBD. the offender's ages were 30-50 dominantly Assaults and thefts were concentrated in Songan-gil(street). which is a place teen-ages and youngsters meet frequently The result of the buffering analysis with roads, explained 40% of crime within a 30m buffer area( including both sides) of a principal road The rest of the climes mainly occurred in the vicinity of narrow streets and alleys.

  • PDF

Frequent Forest Fire in Kosong-Gun, Kangwon Province (고성지방의 산불발생)

  • 이장렬
    • The Korean Journal of Quaternary Research
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • In this paper, the writer attempts to clarify causes by general man and weather factor on forest fire occurrence in Kosong-Area, 1995-2001. The major results are summarized as follows: The forest fire at Kojin-ri, Sonyusil-ri and Majwa-ri occurred at the same area over 3 times and that Hakya-ri, Songdae-ri and Inhung-ri, at the adjoining land over 3times. In the total 46 times of forest fire, fire frequence was greatest in March(11 time) and April(11 time) followed by November(7 time), January(6 time), February(6 time). December(3 time), October(2 time). Hours on frequent forest fire are from 11:00 till 18:00. Number for forest fire occurrence by causes was greatest in military training followed by burning paddy fields, debris burning, burning agricultural debris, visiting a grave, cigarette and arson. Frequent forest fire in Kosong-Area coincide not only with above normal temperatures, but also with below normal relative humidity. When the strong winds appear at Kosong-Area, the properties of daily surface chart re the south high and north low pressure pattern in the Far East Asia.

  • PDF

Arson Fire Analysis Involving the Use of Flammable Liquilds as Accelerants (인화성액체를 촉진제로 사용한 방화화재의 감식기법에 관한 연구)

  • Choi, Min-Ki;Han, Dong-Hun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.64-72
    • /
    • 2014
  • Flammable liquids residues in fire debris and pyrolysis products of flammable materials were analyzed by using Gas detecting tube, Gas Chromatograph/Mass Spectrometers (GC/MS), and Pyrolyzer. Comparison studies between chemical components detected in debris fired with and without Flammable liquids were performed. Though Flammable liquids were not present in debris, Gas detecting tube colors were also changed. Chemical components produced from conventional combustions were different from those produced from pyrolysis. Due to the difference of the reaction conditions between combustions and pyrolysis, different chemical products were produced. Petrochemical products of PVC wood-linoleum block could produce ignitable chemicals, such as toluene, ethylbenzene, undecane, and dodecane. So, for better fire investigation more consideration of those chemicals will be porformed.

The Comparison on the Investigative Training between the Current Korean National Police and the Law Enforcement Agencies of U.S.A. and Germany (현 대한민국 경찰의 수사교육과 미국, 독일 수사기관과의 비교)

  • Kim, Dae-Sik;Lee, Sang-Han
    • Journal of forensic and investigative science
    • /
    • v.2 no.1
    • /
    • pp.52-80
    • /
    • 2007
  • In the rapidly changing current society, the Korean National Police(KNP) is facing a lot of demands from the citizens like the protection of subject/victim rights, independence of investigation authority, disclosure of actual truth, and prevention & eradication of crimes. It is widely recognized among the Korean people and the police that the KNP is always standing for the rights of the people and it is high time that the KNP should be restored as the pioneer for the protection of human right. In this situation, the tremendous emphasis is given on the importance of investment in investigative training through the long-term master-plan in order to renovate its constitution, to level up its quality, and to cope with the highly sophisticated crime patterns. Korean police have already shown its outstanding investigative skills of identification of the deceased throughout large cases like Daegu subway arson and tsunami in Southeast Asia. In addition, the skills of cyber crime investigation are highly recognized by foreign law enforcement agencies. However, the investigative skills and abilities are being degraded and the morale of the investigative personnel are falling due to the insufficiently of the finite training budget. Lack of financial support results in the lack of training program and poor training environment, which subsequently leads to the inefficiency of training. Additionally, no long-term budget for fostering specialized investigative agents is allotted. Considering the fact that more than 95% of crimes in Korea are being primarily investigated by the Korean police, we have to understand the importance of the police. By the tremendous investment in investigative training which can lead to the high-quality investigations, the Korean police can ultimately contribute to the protection of safety and life of its people.

  • PDF

Research and Analysis of the Causes and Preventive Measures of Fires Caused by a Disposable Gas Lighter (1회용 가스라이터로 인한 화재 원인과 예방대책의 조사·분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This study analyzed the regulatory actions of disposal gas lighters as well as the situations, causes, and preventive measures of fires, and accidents caused by disposal gas lighters. Since child-resistant lighters became mandatory, the percentage of fires caused by playing with fire has decreased in Korea as it did in America and Japan. Fires caused by disposal gas lighters can occur by afterburning, unintentional lighting, large flames, or explosion or bursting as well as by arson and playing with fire. This study suggests the preventive measures of fires caused by disposal gas lighters as follows: Taking a step not to be used as child's tool for playing with fire, the warning of fire cases caused by afterburning, warning of the dangers of leaving disposal gas lighters on the car dashboard or high temperature places, improving the protective synthetic resin cover of the stop part of a vehicle seat rail, and providing information on precautions for keeping in drawers or disposition methods.

The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties (스프링클러 소화설비의 목조문화재 소화성능에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Dong-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.51-57
    • /
    • 2011
  • The domestic wooden cultural properties applied to the sprinkler extinguishing system was confirmed extinguishing performance through fire experiments. Consists of wooden cultural properties of a fire, a flammable material is vulnerable in terms of. The scale of fire will occur to vary appearance of the initial fire in case of arson. Sprinkler nozzles of the characteristics, the discharging pressure is 1 bar and the flow rate is 80 lpm, applied in this experiment. Fire performance experiments were tested in two separated in each of the scale of the fire and cultural properties. Fire extinguishing performance test results was low in high ceilings and two or more units of the fire scale. Fire growth environment of the actual wooden cultural properties to experimental models when you consider that it is more vulnerable, sprinkler extinguishing system is required sufficient verification in order to apply fire protection of the wooden cultural properties.

A Study on the Possibility of Ignition by Disposable Lighter (사례를 통한 화재사(火災死)의 이해)

  • Jae, J.J.;Lee, C.W.;Keon, H.S.;Son, J.B.;Lee, J.I.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.59-75
    • /
    • 2007
  • The causes of the fire casualties were the heat burns, contacted by flame, before the period of industrialization. According to the economic has been developed drastically since 1990, residing space has been become bigger and sophistication and interior finishing materials have been diversified. Therefore, the suffocation casualties, caused by inspiration of toxic combustion gases, have been more increased than the flame casualties in recently. Also, the arson casualties have been increasing with the increasing of insurance crime to take the Insurance money. According to National Emergency Management Agency announcement, 31,778 fires was occurred nationwide in 2006 and the total casualties were 2,180 occurred. 446 persons were died among them. Because the exact investigation of fire, occurred the death, is very especially important that civil and criminal cases will be happened. Therefore, we studied about the cause of fire, the place of origin, and the group of casualties age on the axies of fires, which were occurred recently. And the identification method of fire casualties, the human behavior characteristic, the flame casualties and the suffocation casualties at fire scene.

  • PDF

He Study of Fire Suppression Capability of Low Pressure Water-Mist System for Wooden Cultural Properties (목조한옥에 대한 저압식 미분무 소화설비의 소화성능에 관한 연구)

  • Roh, Sam-Kew;Kim, Dong-Cheol;Ham Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.401-410
    • /
    • 2012
  • The study verified the extinguishing performance of the low pressure water-mist system, which is used to extinguish fire at domestic wooden architecture, through a fire test. Made of inflammable materials, a wooden house is vulnerable to fire, and the size of fire may vary from the early stage in case of arson. With the discharging pressure of 8 bar and the flow rate of 35 lpm, the low pressure water-mist nozzle used in the experiment has considerable discharging amount compared to other water-mist nozzles. The extinguishing performance was tested based on the size of fire and architecture. Test results demonstrated that the extinguishing performance was not affected by the size of a house, but decreased significantly when the size of fire was above unit 1. Taking into account that the environment of actual wooden cultural properties is more vulnerable than that of the experiment model, sufficient investigation on extinguishing performance is required to apply the water-mist extinguishing system to wooden architecture.

Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures (3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.