• Title/Summary/Keyword: array sensors

Search Result 479, Processing Time 0.023 seconds

Recognition resolution enhancement of ultrasonic sensors via multiple steps of transmitter voltages

  • Na, Seung-You;Park, Min-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.409-412
    • /
    • 1996
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensing are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensor has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained with neither the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

Disturbance Elimination Performance Improvement of A Magnetic Levitation System by Array-Sensor Calibration (센서 배열의 보정에 의한 자기 부상 시스템의 외란 제거 성능 개선)

  • An, Myung-Kook;Na, Seung-You
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.278-281
    • /
    • 2002
  • In this paper we propose a controller which has the capability of disturbance measurement calibration for Cds array sensors in a magnetic levitation system. Steady state error due to environment light condition or external disturbance is corrected constantly. The correction is made by the sensors to measure the ball position of the system without additional deployment of sensors.

  • PDF

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Design and fabrication of wafer scale microlens array for image sensor using UV-imprinting (UV 임프린팅을 이용한 이미지 센서용 웨이퍼 스케일 마이크로렌즈 어레이 설계 및 제작)

  • Kim, Ho-Kwan;Kim, Seok-Min;Lim, Ji-Seok;Kang, Shin-Ill
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.100-103
    • /
    • 2007
  • A microlens array has been required to improve light conversion efficiency in image sensors. A microlens array can be usually fabricated by photoresist reflow, hot-embossing, micro injection molding, and UV-imprinting. Among these processes, a UV-imprinting, which is operated at room temperature with relatively low applied pressure, can be a desirable process to integrate microlens array on image sensors, because this process provides the components with low thermal expansion, enhanced stability, and low birefringence, furthermore, it is more suitable for mass production of high quality microlens array. In this study, to analyze the optical properties of the wafer scale microlens array integrated image sensor, another wafer scale simulated image sensor chip array was designed and fabricated. An aspherical square microlens was designed and integrated on a simulated image sensor chip array using a UV-imprinting process. Finally, the optical performances were measured and analyzed.

  • PDF

Beam Analysis of Underwater Conformal Array by Using Cylindrical Acoustic Holography (원통면 음향 홀로그래피를 이용한 수중음향 곡면배열센서의 빔 해석)

  • Kwon, Hyu-Sang;Park, Seong-Chol;Seo, Hee-Seon;Shin, Gu-Kyun;Joh, Ghee-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.987-995
    • /
    • 2009
  • As an experimental technique to analyze the far-field characteristics of underwater cylindrical array sensors, cylindrical acoustic holography is studied. Inside an laboratory water tank, far-field directivity patterns as well as near-field source images are reconstructed from the measured hologram by hydrophone array. Approximate equation for far-field directivity estimation is derived based on stationary phase method. The simulation and experiment show well usefulness of the proposed method in application of underwater array sensors.

Beam analysis of underwater conformal array by using cylindrical acoustic holography (원통면 음향 홀로그래피를 이용한 수중음향 곡면배열센서의 빔 해석)

  • Kwon, Hyu-Sang;Park, Seong-Chol;Seo, Hee-Seon;Shin, Gu-Kyun;Joh, Ghee-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.111-116
    • /
    • 2009
  • As an experimental technique to analyze the far-field characteristics of underwater cylindrical array sensors, cylindrical acoustic holography is studied. Inside an laboratory water tank, far-field directivity patterns as well as near-field source images are reconstructed from the measured hologram by hydrophone array. Approximate equation for far-field directivity estimation is derived based on stationary phase method. The simulation and experiment show well usefulness of the proposed method in application of underwater array sensors.

  • PDF

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

Post-processing Technique for Improving the Odor-identification Performance based on E-Nose System

  • Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.368-372
    • /
    • 2015
  • In this paper, we proposed a post-processing technique for improving classification performance of electronic nose (E-Nose) system which may be occurred drift signals from sensor array. An adaptive radial basis function network using stochastic gradient (SG) and singular value decomposition (SVD) is applied to process signals from sensor array. Due to drift from sensor's aging and poisoning problems, the final classification results may be showed bias and fluctuations. The predicted classification results with drift are quantized to determine which identification level each class is on. To mitigate sharp fluctuations moving-averaging (MA) technique is applied to quantized identification results. Finally, quantization and some edge correction process are used to decide levels of the fluctuation-smoothed identification results. The proposed technique has been indicated that E-Nose system was shown correct odor identification results even if drift occurred in sensor array. It has been confirmed throughout the experimental works. The enhancements have produced a very robust odor identification capability which can compensate for decision errors induced from drift effects with sensor array in electronic nose system.

Analysis of Breath from Diabetic Patients Based on a One-chip-type Sensor Array

  • Yu, Joon-Boo;Jang, Byoung Kuk;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.221-224
    • /
    • 2019
  • Based on the results of studies on acetone excretion in diabetic patients, a one - chip sensors array was fabricated by combining acetone-selective sensor materials and volatile-organic-compound sensitive sensor materials. An electonic-nose was implemented using a sensor array and confirmed selectivity for five gases. In this system, the excretion of diabetic patients and controls was sampled with solid phase microextraction fiber and transferred to the sensor array. Although the control and diabetic patients were distinct, several samples failed. In the control group, the results of blood tests were normal, but patients were highly obese. In addition, the gas chromatography mass spectrometry results for the subjects revealed chemicals that are external factors.

Demonstration of Robust Micromachined Jet Technology and Its Application to Realistic Flow Control Problems

  • Chang Sung-Pil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.554-560
    • /
    • 2006
  • This paper describes the demonstration of successful fabrication and initial characterization of micromachined pressure sensors and micromachined jets (microjets) fabricated for use in macro flow control and other applications. In this work, the microfabrication technology was investigated to create a micromachined fluidic control system with a goal of application in practical fluids problems, such as UAV (Unmanned Aerial Vehicle)-scale aerodynamic control. Approaches of this work include: (1) the development of suitable micromachined synthetic jets (microjets) as actuators, which obviate the need to physically extend micromachined structures into an external flow; and (2) a non-silicon alternative micromachining fabrication technology based on metallic substrates and lamination (in addition to traditional MEMS technologies) which will allow the realization of larger scale, more robust structures and larger array active areas for fluidic systems. As an initial study, an array of MEMS pressure sensors and an array of MEMS modulators for orifice-based control of microjets have been fabricated, and characterized. Both pressure sensors and modulators have been built using stainless steel as a substrate and a combination of lamination and traditional micromachining processes as fabrication technologies.