• 제목/요약/키워드: arm CT

검색결과 67건 처리시간 0.031초

Determination of In-Vivo Glenohumeral Translation During Loaded and Unloaded Arm Elevation

  • Nishinaka, Naoya;Mihara, Kenichi;Suzuki, Kazuhide;Makiuchi, Daisuke;Matsuhisa, Takayuki;Tsutsui, Hiroaki;Kon, Yoshiaki;Banks, Scott A.
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2009년도 제17차 학술대회
    • /
    • pp.44-44
    • /
    • 2009
  • The purpose of this study was to investigate humeral translation relative to the glenoid invivo during loaded and unloaded shoulder abduction. CT scans of 9 healthy shoulders were acquired and 3D models were created. The subject was positioned in front of a fluoroscope and motions were recorded during active abduction. The subjects performed two trials of holding a 3kg weight and unload. 3D motions were determined using model-based 3D-to-2D registration to obtain 6 degrees of freedom kinematics. Glenohumeral translation was determined by finding the location on the humeral head with the smallest separation from the glenoid. Humeral translation was referenced to the glenoid center in the superior/inferior direction. The humerus moved an average of 2 mm, from inferior to central on the glenoid, during arm abduction for both conditions. The humeral head was centered within 1mm from the glenoid center above $70^{\circ}$. There were no statistically significant differences for both conditions. The standard deviation decreased gradually over the motion, with significantly lower variability at the end of abduction compared to the initial unloaded position. We assumed that the humeral translation to the center of the glenoid provides maximum joint congruency for optimal shoulder function and joint longevity. We believe this information will lead to better strategies to prevent shoulder injuries, enhance rehabilitation, and improve surgical treatments.

  • PDF

Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears

  • Yuji Yamada;Yoshihiro Kai;Noriyuki Kida;Hitoshi Koda;Minoru Takeshima;Kenji Hoshi;Kazuyoshi Gamada;Toru Morihara
    • Clinics in Shoulder and Elbow
    • /
    • 제25권4호
    • /
    • pp.265-273
    • /
    • 2022
  • Background: Massive rotator cuff tears (MRCTs) with subscapularis (SSC) tears cause severe shoulder dysfunction. In the present study, the influence of SSC tears on three-dimensional (3D) shoulder kinematics during scapular plane abduction in patients with MRCTs was examined. Methods: This study included 15 patients who were divided into two groups: supraspinatus (SSP) and infraspinatus (ISP) tears with SSC tear (torn SSC group: 10 shoulders) or without SSC tear (intact SSC group: 5 shoulders). Single-plane fluoroscopic images during scapular plane elevation and computed tomography (CT)-derived 3D bone models were matched to the fluoroscopic images using two-dimensional (2D)/3D registration techniques. Changes in 3D kinematic results were compared. Results: The humeral head center at the beginning of arm elevation was significantly higher in the torn SSC group than in the intact SSC group (1.8±3.4 mm vs. -1.1±1.6 mm, p<0.05). In the torn SSC group, the center of the humeral head migrated superiorly, then significantly downward at 60° arm elevation (p<0.05). In the intact SSC group, significant difference was not observed in the superior-inferior translation of the humeral head between the elevation angles. Conclusions: In cases of MRCTs with a torn SSC, the center of the humeral head showed a superior translation at the initial phase of scapular plane abduction followed by inferior translation. These findings indicate the SSC muscle plays an important role in determining the dynamic stability of the glenohumeral joint in a superior-inferior direction in patients with MRCTs.

Learning Curve of C-Arm Cone-beam Computed Tomography Virtual Navigation-Guided Percutaneous Transthoracic Needle Biopsy

  • Su Yeon Ahn;Chang Min Park;Soon Ho Yoon;Hyungjin Kim;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.844-853
    • /
    • 2019
  • Objective: To evaluate the learning curve for C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous transthoracic needle biopsy (PTNB) and to determine the amount of experience needed to develop appropriate skills for this procedure using cumulative summation (CUSUM). Materials and Methods: We retrospectively reviewed 2042 CBCT virtual navigation-guided PTNBs performed by 7 novice operators between March 2011 and December 2014. Learning curves for CBCT virtual navigation-guided PTNB with respect to its diagnostic performance and the occurrence of biopsy-related pneumothorax were analyzed using standard and risk-adjusted CUSUM (RA-CUSUM). Acceptable failure rates were determined as 0.06 for diagnostic failure and 0.25 for PTNB-related pneumothorax. Results: Standard CUSUM indicated that 6 of the 7 operators achieved an acceptable diagnostic failure rate after a median of 105 PTNB procedures (95% confidence interval [CI], 14-240), and 6 of the operators achieved acceptable pneumothorax occurrence rate after a median of 79 PTNB procedures (95% CI, 27-155). RA-CUSUM showed that 93 (95% CI, 39-142) and 80 (95% CI, 38-127) PTNB procedures were required to achieve acceptable diagnostic performance and pneumothorax occurrence, respectively. Conclusion: The novice operators' skills in performing CBCT virtual navigation-guided PTNBs improved with increasing experience over a wide range of learning periods.

유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상 (The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA)

  • 최인호;차경석;정동화
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.213-230
    • /
    • 2008
  • 최근 치료기간의 단축과 심미성을 동시에 충족시키는 6전치를 설측에서 견인하는 레버암을 이용한 견인방법이 사용되고 있다. 본 연구에서는 상악골의 고전적인 2가지 물성으로 구성된 유한 요소 모델 (단순모델)과 새로이 개발된 24가지 물성으로 구성된 모델 (복합모델)을 생성하여 상악 6전치를 후방 견인 시, 각 치아와 치주인대에 나타나는 초기 이동량과 응력분포를 분석하였다. 23세 성인 남자의 CT 촬영으로 얻은 DICOM 영상정보를 3차원 리버스 엔지니어링 컴퓨터영상프로그램 Mimics를 이용하여 상악골 및 상악 전치부의 3차원 입체영상모델로 재구성하여 finite element analysis (FEA) 모델을 완성하였다. 모델은 상악골, 상악 전치부 각 치아의 치주인대, lingual traction arm의 부분으로 구성되었다. 상악 6전치의 저항중심 부위를 지나도록 교합면에 대하여 평행하게 200g의 후방견인력을 적용한 후 나타나는 초기 이동량 및 응력 분포를 3차원 유한 요소법을 이용한 해석을 통해 비교하였다. 실험 결과 24가지 물성으로 구성된 복합모델이 2가지 물성으로 구성된 단순 모델에 비해 상악 중절치에서 보다 후방 이동되는 양상이 크게 나타났으며 수직적인 회전 양상 역시 크게 나타났다. 두 모델 모두 중절치와 측절치는 조절성 경사이동의 형태로 후방이동양이 견치보다 크게 나타났으나 견치는 이동량이 적은 대신 치근의 이동이 더 크게 나타났다. 수직적 이동양상에 있어 두 모델 모두 측절치와 견치의 접촉점을 중심으로 절치는 하방으로 견치는 상방으로 움직이는 회전양상을 나타났다. 응력의 비교에서는 단순 모델과 복합 모델에서 유사한 결과를 보였다. 비록 각기 다른 물성으로 인해 후방 이동량에서는 차이가 나타났으나 기본적인 치아의 이동양상은 두 모델에서 모두 같게 나타났다.

코뼈 골절 환자 452례에 대한 임상 통계학적 분석 (Clinical and Statistical Analysis in 452 Cases of Nasal Bone Fracture Patients)

  • 강재훈;방유현;이용해;최창용
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.775-782
    • /
    • 2011
  • Purpose: Nasal bone fracture is most common facial bone fracture. The cause of fractures is mainly trauma such as fighting, automobile accident and fall down, and it commonly involves young males. Very frequently nasal bone fractures are associated with other facial injuries such as orbital bone fracture, maxillary bone fracture and nasal septal deformities. Because of various dynamic directions of power are involved, phenomenon of fractures are also various and treatment cannot be simple. Methods: We studied and analyzed retrospectively 452 cases nasal bone fractures from January 2008 to December 2010. Diagnosis were made with physical examination, Nasal bone X-rays, Facial bone CT and 3D facial bone CT. Four surgeons are involved in treatments of these patients and applied different procedure along patient's condition and deformity. We analyzed the cause of nasal bone fractures, deformities, associate injuries and applied surgical technique, and patient's satisfaction rate. In this study, old nasal bone fractures were excluded. Results: Young male group was most commonly sustained nasal bone fracture and physical violence was most common cause of injury. 64 of 452 patient was involved associate injuries of face. Closed reduction were applied 246 cases and C-arm quide reduction were 167 cases and in 20 cases lateral osteotomy were applied. Approximately, more than 80% of the Patients were satisfied with the outcomes. Conclusion: Diagnosis and treatment of nasal bone fractures are considered simple but because of various deformity and associate injuries, treatment is not always simple and universal. Time to time, we face unsatisfied patient after treatment of nasal bone fractures. For obtaining satisfactory result, cause of injury and state of deformities and associate injuries such as nasal septal deformity should be evaluated properly and proper treatment should be applied.

Percutaneous Sacroplasty : Effectiveness and Long-Term Outcome Predictors

  • Lee, Jaehyung;Lee, Eugene;Lee, Joon Woo;Kang, Yusuhn;Ahn, Joong Mo;Kang, Heung Sik
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.747-756
    • /
    • 2020
  • Objective : To evaluate the effectiveness and long-term outcome predictors of percutaneous sacroplasty (PSP). Methods : This single-center study assessed 40 patients with sacral insufficiency fractures using the short-axis technique under C-arm flat-panel detector computed tomography (CT). Two radiologists reviewed the patients' magnetic resonance and CT images to obtain imaging findings before PSP and determine technical success, respectively. The short-term outcomes were visual analog scale score changes and opioid usage reductions. Long-term outcomes were determined using telephone interviews and the North American Spine Society (NASS) patient-satisfaction index at least one year after PSP. Results : Technical success was achieved without any significant complications in 39 patients (97.5%). Telephone interviews were possible with 12 patients and failed in 10 patients; death was confirmed in 18 patients. Fifteen patients (50%) re-visited the hospital and received conservative treatment, including spinal injections. Nine patients reported positive satisfaction (NASS patient-satisfaction index 1 or 2), while the negative satisfaction group (NASS patient-satisfaction index 3 or 4, n=3) showed a higher incidence of compression fractures at the thoracolumbar spine level (66.7% vs. 22.2%) and previous spinal injection history (66.7% vs. 33.3%). The poor response group also showed higher incidences of facet joint arthrosis (100% vs. 55.6%), central canal stenosis (100% vs. 22.2%), neural foraminal stenosis (33.3% vs. 22.2%), scoliosis (100% vs. 33.3%), and sagittal malalignment (100% vs. 44.4%). Conclusion : PSP was effective for sacral insufficiency fractures and showed good long-term outcomes. Combined compression fractures in the thoracolumbar spine and degenerative lumbar pathologies could be possible poor outcome predictors.

Slip-Related Changes in Plantar Pressure Distribution, and Parameters for Early Detection of Slip Events

  • Choi, Seungyoung;Cho, Hyungpil;Kang, Boram;Lee, Dong Hun;Kim, Mi Jung;Jang, Seong Ho
    • Annals of Rehabilitation Medicine
    • /
    • 제39권6호
    • /
    • pp.897-904
    • /
    • 2015
  • Objective To investigate differences in plantar pressure distribution between a normal gait and unpredictable slip events to predict the initiation of the slipping process. Methods Eleven male participants were enrolled. Subjects walked onto a wooden tile, and two layers of oily vinyl sheet were placed on the expected spot of the 4th step to induce a slip. An insole pressure-measuring system was used to monitor plantar pressure distribution. This system measured plantar pressure in four regions (the toes, metatarsal head, arch, and heel) for three events: the step during normal gait; the recovered step, when the subject recovered from a slip; and the uncorrected, harmful slipped step. Four variables were analyzed: peak pressure (PP), contact time (CT), the pressure-time integral (PTI), and the instant of peak pressure (IPP). Results The plantar pressure pattern in the heel was unique, as compared with other parts of the sole. In the heel, PP, CT, and PTI values were high in slipped and recovered steps compared with normal steps. The IPP differed markedly among the three steps. The IPPs in the heel for the three events were, in descending order (from latest to earliest), slipped, recovered, and normal steps, whereas in the other regions the order was normal, recovered, and slipped steps. Finally, the metatarsal head-to-heel IPP ratios for the normal, recovered, and slipped steps were $6.1{\pm}2.9$, $3.1{\pm}3.0$, and $2.2{\pm}2.5$, respectively. Conclusion A distinctive plantar pressure pattern in the heel might be useful for early detection of a slip event to prevent slip-related injuries.

3차원 입체조형치료에 의한 아교모세포종의 방사선 선량증가 연구 (Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy)

  • 조재호;이창걸;김경주;박진호;이세병;조삼주;심수정;윤덕현;장종희;김태곤;김동석;서창옥
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.237-246
    • /
    • 2004
  • 목적: 아교모세포종의 방사선치료에서 국소제어율과 생존율을 향상시켜 보고자 3차원 입체조형치료기법을 이용한 방사선선량 증가 연구를 전향적으로 시행하였다. 대상 및 방법: 1997년 1월부터 2002년 7월까지 아교모세포종으로 조직학적 진단이 되고 전신수행도(KPS)가 60 이상으로 수술 후 방사선치료를 받은 환자를 대상으로 하였다. 프로토콜에 따라 전향적으로 연구에 참여한 42예의 고선량군과 후향적 대조군인 33예의 저선량군을 비교 분석하였다 고선량군은 3차원 입체조형치료법에 의해 $63.0\~70.2$ Gy (중앙값 66 Gy)의 고선량 방사선을 조사받았으며, 저선량군은 2차원 치료방식으로 현재 표준선량으로 여겨지고 있는 59.4 Gy 정도(최소선량 50.4 Gy, 중앙선량 59.4 Gy)의 계획된 방사선치료를 종료할 수 있었던 환자들을 대상으로 하였다. 수술절제범위에 따라 나누어보면 전절제술 30예($40\%$), 준전절제술 30예($40\%$), 부분절제술 8예($11\%$), 그리고 조직생검만 시행된 환자가 7예($9\%$)였다. 각 환자의 육안종양체적은 CT 혹은 MRI상 수술절제연 및 잔류종양에 의해 정의되었다. 종양주변 부종은 저선량군에서는 임상표적체적에 포함되었지만, 고선량군에서는 재발양상 및 선량증가에 따른 합병증 증가의 가능성을 고려하여 제외하였다. 환자의 전체 및 무진행생존기간은 수술 받은 날을 기준으로 Kaplan-Meier법으로 산출하였고, 기존 문헌에 보고되고 있는 예후인자들과 각 환자에 조사된 방사선 선량, 표적체적 등이 생존율에 미치는 영향을 Log rank test 및 Cox regression analysis로 분석하였다. 추적관찰을 위해 정기적으로 MRI가 시행되었다. 결과: 전체환자의 중앙 생존기간 및 무진행 생존기간은 각각 $15{\pm}1.65$, $11{\pm}0.95$개월이었다. 중앙생존기간은 저선량군 및 고선량군이 각각 $14{\pm}0.94$개월, $21{\pm}5.03$개월로 고선량군에서 보다 나은 치료성적을 보여주었으며, 중앙무진행생존기간은 저선량군 $10{\pm}1.63$개월, 고선량군 $12{\pm}1.59$개월이었다. 특히 2년 생존율에 있어서 고선량군은 $44.7\%$$19.2\%$인 저선량군에 비해 훨씬 좋은 예후를 보였다. 단변량분석에서 예후에 영향을 미치는 중요인자로는 환자의 나이, 전신수행도, 종양의 위치, 수술절제범위, 표적체적, 방사선총선량 등이었다 다변량분석에서 통계적으로 유의한 인자는 환자의 나이(p=0.012), 수술절제범위(p=0.000), 방사선선량군(p=0.049)이었다. 방사선괴사와 같은 방사선으로 인한 직접적인 만성합병증은 추적관찰기간 동안 발생하지 않았다. 결론: 3차원 입체조형치료기법을 통하여 70 Gy까지의 방사선을 부작용 없이 조사할 수 있었고, 근치적 국소요법의 일환으로 방사선 선량증가가 전체 생존기간 및 무진행 생존기간을 향상시킬 수 있을 것으로 기대한다.

CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함) (Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN))

  • 장위잉;정하오양;정강교;조유진;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.567-573
    • /
    • 2017
  • 본 연구의 목적은 흉 복부 다중검출기전산화단층촬영(multi-detector computed tomography; MDCT)에서 상지를 머리 위로 위치 잡이 할 수 없는 경우 흉 복부에서 거리에 따른 인공유무를 평가하고자 하였다. 128-채널 MDCT로 흉 복부 CT를 위한 인체대상과 흉부 팬텀을 현재 임상에서 검사하고 있는 조건(120 kVp, 110 mAs, standard algorithm)으로 검사하였다. 인체 검사 시 한번은 팔을 머리 쪽으로 올리고 검사하고, 팔을 내린 후 동일한 조건으로 한 번 더 검사하였다. 흉부 팬텀 실험은 환자와 동일한 조건으로 검사를 하고, 상지팬텀을 흉 복부에서 일정한 거리(0, 3, 7 cm)를 두고 검사하였다. 목적하는 부위에 관심영역을 설정하여 CT 값, 노이즈, 신호 대 잡음비, 대조도 대 잡음비를 측정하여 평가하였다. 인체를 대상으로 획득한 영상에서 노이즈는 팔을 올렸을 때와 비교하여 팔을 내렸을 때 지방, 갈비뼈, 근육 모두에서 증가하였다(0.79, 47.8, 27%). 팬텀 영상에서도 상지를 아래로 내렸을 경우 근육, 폐 실질에서 노이즈가 증가하였다(31.2, 9.4%). 또한 상지의 위치가 흉 복부에서 멀어질수록(0, 3, 7 cm) 노이즈가 감소하였다. 근육에서 노이즈는 상지가 흉부와 붙어있을 경우(0 cm)를 기준으로 3 cm, 7cm 떨어졌을 때 5, 25.12% 감소하였고, 폐실질에서 5.6, 15.35% 감소하였다. 흉 복부 CT 촬영 시 갠트리 내 검사 이외의 부위(상지 등)가 위치할 경우 흉 복부로부터 약 3 cm 이상 거리를 유지시킨 후 검사를 진행하면 발생할 수 있는 인공음영을 최소화시킬 수 있을 것으로 사료된다.

Late-onset Brachial Artery Occlusion caused by Subclavian Artery Stenosis after Clavicular Fracture: A Case Report

  • 조철현;송광순;민병우;배기채
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2008년도 제16차 학술대회
    • /
    • pp.175-175
    • /
    • 2008
  • We report a rare case of late-onset brachial artery occlusion caused by subclavian artery stenosis with excessive scar tissue after open reduction and plate fixation for clavicular fracture. When he referred to us, the right hand were pale and the radial and ulnar pulses at the wrist were absent. CT-angiogram showed compression of subclavian artery by excessive scar tissue beneath the fracture site and angiography revealed stenosis of subclavian artery with thrombus and complete obstruction of blood flow in the brachial artery with emboli. Therefore, we performed embolectomy. 2 years after operation, patient was essentially asymptomatic except mild pain after long standing elevation of arm. We recommend that minimal soft tissue dissection should be needed in the operative treatment of clavicular fracture, especially soft tissue beneath the clavicle should be protected maximally.

  • PDF