• 제목/요약/키워드: argon

Search Result 1,172, Processing Time 0.033 seconds

The resistivity properties of tungsten nitride films deposited by RF sputtering (RF 스퍼터링 증착에 의한 질화 텅스텐 박막의 비저항 특성)

  • 이우선;정용호;이상일
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.196-203
    • /
    • 1995
  • We presented Tungsten and Tungsten Nitride thin films deposited by RF and DC sputtering. It deposited at various conditions that determining the resistivity and sheet resistivity by stabilizing the basic theory. We investigated properties of the resistivity and sheet resistivity of these films under various conditions, temperature of substrate, flow rate of the argon gas and content of nitrogen from nitrogen-argon mixtures. As the temperature of substrate increased and the flow rate of the argon gas decreased, the resistivities of these films reduced by structural transformation. We found that these resistivities were depend on the temperature of substrate, flow rate and electric power. Very highly resistive tungsten films obtained at 10W RF power. On the contrary, we found that films deposited by DC sputtering, from which very lowly resistive tungsten films were obtained. Tungsten nitride thin films deposited by reactive DC sputtering and the resistivities of these films increased as the content of nitrogen gas increased from nitrogen-argon mixture. And also we found the results show very good agreement, compared with experimental data.

  • PDF

A COMPARATIVE STUDY ON THE ANTICARIOGENICITY OF ENAMEL SURFACE ADJACENT TO RESIN RESTORATION POLYMERIZED BY VISIBLE LIGHT OR ARGON LASER. (가시광선과 아르곤 레이저에 의해 중합된 레진 수복물 주변 법랑질의 항우식효과에 관한 비교연구)

  • Park, Young-Soo;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.840-858
    • /
    • 1996
  • The main purpose of this study was to evaluate the anticariogenic effect of argon laser. Histological observations on lesion initiation and progression were performed under the polarized microscope. The results from the present study can be summarized as follows; 1. The specimens of laser cured group were shown to have more irregular and discontinuous lesion body in general than visible light cured group with rather continuous positive birefringence. 2. With lesion initiation and progression, almost all the specimens showed deeper body of lesion with shallower intact surface zone in the visible light cured group than the laser cured group(p<0.05). When the comparision was made between the two argon laser cured groups, the single-cure group showed deeper lesion body and the shallower surface layer than double-cure group. 3. Based upon the above mentioned results of this study, it can be assumed that the use of argon laser in the procedure of resin polymerization may provide the child and adolescent patient population with anticariogenic effect as well as efficient polymerization. Further studies using various materials and experimental conditions are being encouraged.

  • PDF

MICROLEAKAGE OF COMPOSITE RESINS POLYMERIZED WITH ARGON LASER AND VISIBLE LIGHT (가시광선과 아르곤 레이저로 복합레진 중합시 미세누출에 관한 비교 연구)

  • Jang, Ki-Taeg;Chung, Tae-Ryun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.899-905
    • /
    • 1996
  • For the purpose of evaluation of microleakage of class V resin restoration, 64 extracted bovine teeth were filled with two kinds of light curing composite resins(Z-100, Clearfil) and polymerized with 40 seconds of visible light and with 10 seconds of argon laser. After 1000 thermocycling($5^{\circ}C/55^{\circ}C$), specimens were placed in 1 % methylen blue dye solution for 72 hours in $37^{\circ}C$ water bath. The specimens were sectioned at center of filling body and the degree of dye penetration was observed with a stereomicroscope. The following results were obtained, 1. Differences of the microleakage of resin restorations polymerized with 10 seconds of argon laser and 40 seconds of visible light were statistically insignificant. 2. There was more microleakage in Z-100 than clearfil and there was a statistical significancy (p<0.05).

  • PDF

Development and Application of a Nonequilibrium Molecular Dynamics Simulation Method to Study Shock Waves Propagating in Argon Gas (아르곤 기체에서 진행하는 충격파 연구를 위한 비평형 분자동역학 모의실험 개발 및 응용)

  • Hwang, Hyon-Seok;Kwon, Chan-Ho;Kim, Hong-Lae;Kim, Seong-Shik;Park, Min-Kyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.156-163
    • /
    • 2010
  • A nonequilibrium molecular dynamics(NEMD) simulation method is developed and applied to study shock waves propagating through argon gas. In this simulation method, shock waves are generated by pushing a piston at a constant speed from one side of a simulation box filled with argon molecules. A linear relationship between piston speeds and shock speeds is observed. Thermodynamic properties including density, temperature, and pressure before and after the shock front are obtained from the simulations and compared with the well-known Rankine-Hugoniot equations based on ideal gases. The comparison shows an excellent agreement, indicating that this NEMD simulation method can be employed to investigate various physical properties of shock waves further.

AN INVESTIGATION ON THE CHARACTERIZATION OF COMPOSITE RESIN POLYMERIZED BY THE USE OF AN ARGON ION LASER (Argon 이온 레이저 중합에 의한 Composite resin의 물성에 관한 연구)

  • Cho, Hyung-Kyung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.69-82
    • /
    • 1992
  • An experimental investigation of the physical properties of light curing composite resin P-50 was performed, in which an argon ion laser beam was irradiated. The physical and mechanical properties of laser polymerized composite resin were determined by measuring the compressive strength, diametral tensile strength, curing depth and microhardness depending upon the experimental conditions such as the laser irradiation time(10sec, 20sec, 30sec) and laser power(300mW, 500mW, 1000mW). These observations were compared with a conventional visible light curing technique. In addition, to evaluate the marginal adaptation, Class V cavity was prepared on the buccal or lingual surface of the extracted premolar and filled with P-50 light curing resin. The test samples were irradiated with both light sources so that the interface between the restoration and the tooth structure were observed under scanning electron microscope. The most of physical and mechanical properties of the laser cured resin showed a remarkable improvement than those treated with the conventional light source, while the observations with the scanning electron microscope provided no significant difference for two polymerized sources. From the results in the experiment it appears that the potential of an argon ion laser is of important value of the use in the polymerization of composite resin.

  • PDF

Luminescence Properties of Argon and Neon Gas Using an Inductively Coupled Plasma (유도결합형 Ar, Ne 가스에서의 플라즈마 발광 특성)

  • Her, In-Sung;Lee, Young-Hwan;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.220-223
    • /
    • 2004
  • Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. Optical characteristics significantly depend on the RF power and gas pressure of the plasma. This paper describes the measurement of luminance as a function of RF power and gas pressure with a goal of finding optimal operating conditions of the electrodeless lamp. The gas pressure was varied from 10[mTorr] to 300[mTorr] or 500[mTorr] and the RF power was varied from 10[W] to 200[W]. It was found that the luminance tends to be decreased when argon and neon pressure is increased, and the luminance is increased as RF power is increased. It was also found that the luminance per unit RF power is high when the argon and neon pressure is low and when the RF power is in the range of $30[W]{\sim}40[W]$ or 10[W].

  • PDF

A simple analysis on the abnormal behavior of the argon metastable density in an inductively coupled Ar plasma

  • Park, Min;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.438-438
    • /
    • 2010
  • The abnormal behavior of the argon metastable density during the E-H mode transition in argon ICP discharge was investigated. Lots of investigations including global models expected that during and after the mode transition of ICP discharge, the density of metastable increases with applied rf power (i.e. electron density). However, recent direct measurement of metastable density revealed that the metastable density of argon decreases with the applied power during and after the mode transition. This result may not be explained by the previous global model which is based on the assumption of the Maxwellian electron energy distribution function (EEDF). In this paper, to explain this abnormal behavior with simple manners, a simple global model taking account of the effect of the non-Maxwellian EEDFs incorporating into a set of coupled rate equations is proposed. The result showed that the calculated metastable density taking account of non-Maxwellian EEDF and its evolution during the transition has an abnormal behavior with electron density and is in good agreement with the previous measurement results, indicating the close coupling of electron kinetics and the behavior of metastable density. The proposed simple model is expected to provide qualitative kinetic insight to understand the behavior of the metastable density in various plasma discharges which typically exhibit non-Maxwellian distribution.

  • PDF

ESTIMATION OF ALUMINUM AND ARGON ACTIVATION SOURCES IN THE HANARO COOLANT

  • Jun, Byung-Jin;Lee, Byung-Chul;Kim, Myung-Seop
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.434-441
    • /
    • 2010
  • The activation products of aluminum and argon are key radionuclides for operational and environmental radiological safety during the normal operation of open-tank-in-pool type research reactors using aluminum-clad fuels. Their activities measured in the primary coolant and pool surface water of HANARO have been consistent. We estimated their sources from the measured activities and then compared these values with their production rates obtained by a core calculation. For each aluminum activation product, an equivalent aluminum thickness (EAT) in which its production rate is identical to its release rate into the coolant is determined. For the argon activation calculation, the saturated argon concentration in the water at the temperature of the pool surface is assumed. The EATs are 5680, 266 and 1.2 nm, respectively, for Na-24, Mg-27 and Al-28, which are much larger than the flight lengths of the respective recoil nuclides. These values coincide with the water solubility levels and with the half-lives. The EAT for Na-24 is similar to the average oxide layer thickness (OLT) of fuel cladding as well; hence, the majority of them in the oxide layer may be released to the coolant. However, while the average OLT clearly increases with the fuel burn-up during an operation cycle, its effect on the pool-top radiation is not distinguishable. The source of Ar-41 is in good agreement with the calculated reaction rate of Ar-40 dissolved in the coolant.

Studies on Nusselt and Sherwood number for diffusion-advective convection during physical vapor transport of Hg2Br2

  • Kim, Geug Tae;Kwon, Moo Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.3
    • /
    • pp.127-136
    • /
    • 2021
  • This paper is dedicated to numerical simulation for diffusion-advective convection in a square cavity during physical vapor transport of Hg2Br2. Flow characteristics of the temperature difference between the source and crystal regions, 50℃ (300℃ → 250℃), partial pressures of component argon of 20 Torr and 100 Torr are investigated and presented as velocity vectors and streamlines, isotherms and iso-mass concentrations contours. Moreover, alterations of average Nusselt and average Sherwood numbers with (a) the source and crystal regions, (b) the pressures of component argon of 20 Torr and 100 Torr are analyzed and addressed in details. Both average Nusselt and average Sherwood numbers are seen to decrease with the increasing values of the partial pressures of component argon. Also, it is found that for the two different partial pressures of component argon, average Nusselt numbers at the source region are greater than at the crystal region, and inversely, average Sherwood numbers at the crystal region are greater than the source region by a factor of 3.

Surface Modification of Steel Tire Cords via Plasma Etching and Plasma Polymer Coating : Part I. Adhesive properties (플라즈마 고분자 코팅에 의한 강철 타이어 코드의 표면 개질 : 제1부. 타이어 코드의 접착성)

  • Kang, H.M.;Chung, K.H.;Kaang, S.;Yoon, T.H.
    • Elastomers and Composites
    • /
    • v.35 no.1
    • /
    • pp.53-62
    • /
    • 2000
  • Zinc plated steel tire cords were treated with RF plasma polymerization coating of acetylene or butadiene in order to enhance adhesion to rubber compounds. Plasma polymerization was carried out as a function of plasma power, treatment tune and gas pressure. In order to maximize adhesion, argon plasma etching was performed, with carrier gas such as argon, nitrogen and oxygen, while the adhesion of tire cords was evaluated via TCAT. Best results were obtained from a combination treatment of argon etching (90 W. 10 min, 30 mTorr) and acetylene plasma polymerization coating (10 W, 30 sec, 30 mTorr) with argon carrier gas (25/5:acetylene/argon). These samples exhibited a pull out force of 285N which is comparable to that obtained from the brass plated tire cords (290N).

  • PDF