• Title/Summary/Keyword: area replacement ratio

Search Result 111, Processing Time 0.022 seconds

Modelling Pasture-based Automatic Milking System Herds: System Fitness of Grazeable Home-grown Forages, Land Areas and Walking Distances

  • Islam, M.R.;Garcia, S.C.;Clark, C.E.F.;Kerrisk, K.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.6
    • /
    • pp.903-910
    • /
    • 2015
  • To maintain a predominantly pasture-based system, the large herd milked by automatic milking rotary would be required to walk significant distances. Walking distances of greater than 1-km are associated with an increased incidence of undesirably long milking intervals and reduced milk yield. Complementary forages can be incorporated into pasture-based systems to lift total home grown feed in a given area, thus potentially 'concentrating' feed closer to the dairy. The aim of this modelling study was to investigate the total land area required and associated walking distance for large automatic milking system (AMS) herds when incorporating complementary forage rotations (CFR) into the system. Thirty-six scenarios consisting of 3 AMS herds (400, 600, 800 cows), 2 levels of pasture utilisation (current AMS utilisation of 15.0 t dry matter [DM]/ha, termed as moderate; optimum pasture utilisation of 19.7 t DM/ha, termed as high) and 6 rates of replacement of each of these pastures by grazeable CFR (0%, 10%, 20%, 30%, 40%, 50%) were investigated. Results showed that AMS cows were required to walk greater than 1-km when the farm area was greater than 86 ha. Insufficient pasture could be produced within a 1 km distance (i.e. 86 ha land) with home-grown feed (HGF) providing 43%, 29%, and 22% of the metabolisable energy (ME) required by 400, 600, and 800 cows, respectively from pastures. Introduction of pasture (moderate): CFR in AMS at a ratio of 80:20 can feed a 400 cow AMS herd, and can supply 42% and 31% of the ME requirements for 600 and 800 cows, respectively with pasture (moderate): CFR at 50:50 levels. In contrast to moderate pasture, 400 cows can be managed on high pasture utilisation (provided 57% of the total ME requirements). However, similar to the scenarios conducted with moderate pasture, there was insufficient feed produced within 1-km distance of the dairy for 600 or 800 cows. An 800 cow herd required 140 and 130 ha on moderate and high pasture-based AMS system, respectively with the introduction of pasture: CFR at a ratio of 50:50. Given the impact of increasing land area past 86 ha on walking distance, cow numbers could be increased by purchasing feed from off the milking platform and/or using the land outside 1-km distance for conserved feed. However, this warrants further investigations into risk analyses of different management options including development of an innovative system to manage large herds in an AMS farming system.

The Settlement Behavior Analysis of SCP of Multi-Layered Ground in Incheon (인천지역 다층지반에 시공된 SCP의 침하거동 분석)

  • Yoon, Won-Sub;Kim, Jong-Kook;Park, Sang-Jun;Cho, Chul-Hyun;Chae, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1042-1050
    • /
    • 2008
  • In this study, SCP method was used by purpose to improve loose sand and soft clay that is drilled Sand Compaction Pile in underground. Settlement behavior of field analyzed through SCP method. When sand Compaction Pile drilled in clay, forming composite ground that foundation and Sand Compaction Pile behavior. According to SCP method can expect bearing capacity improvement, Settlement reduction, lateral flow protection. SCP increase the consolidation settlement of ground and it reduce settlement for that purpose increase liquefaction resistance, lateral Resistance. Because SCP had been widely used for sand. Area of Inchon-A by sand compose clay and silt to upper Ground and compose soft clay to under ground. After pre-loading, it measured settlement by extensometer and settlement extensometer that purpose of ground improvement with 13% in replacement ratio. The result analyzed settlement behavior is similar to Multi-layered Ground that it happened to elastic settlement at upper ground and to consolidation settlement at under ground.

  • PDF

A Study on the Estimation of Ultimate Bearing Capacity of Granular Group Piles (조립토 군말뚝의 극한지지력 평가에 관한 연구)

  • 김홍택;강인규
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.143-162
    • /
    • 1998
  • In the present study, a procedure to predict the depth from the ground surface to the center of bulging failure zone in each of the square granular group piles under a rigid mat foundation is proposed. This analytical procedure is established on the basis of the conical modeling of bulging failure shape and the replacement ratio of soft foundation soils. considering the effect of a share of procedure to estimate the ultimate cylindrical pressure in the area reinforced with granular piles and the ultimate bearing capacity of each of granular piles in group. This analytical procedure is also established on the basis of the pre-determined depth to the zone of bulging failure and an iterative solution technique. Finally the analytical procedures proposed in this study are verified by analyzing the results of 3D finite element analyses, and the predictions of ultimate bearing capacity of granular piles are compared with the results obtained from the tests, empirical equation and 3D finite element analyses.

  • PDF

A Comparative Study on the Effect of Promoting Consolidation between SCP and GCP (SCP와 GCP의 압밀촉진효과에 관한 비교 고찰)

  • You, Seung-Kyong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • In this paper, a series of model tests were performed in laboratory to evaluate promoting consolidation of compaction pile methods for soft ground improvement. For the model tests, composite soil samples that have 10% replacement area ratio were prepared by using sand, gravel, and sandy gravel for the materials of compaction piles. After loading to each composite soil sample, the excess pore pressure dissipation and settlement were investigated. In addition, the behavior of clay mixed with each compaction pile was also monitored at the end of consolidation to evaluate clogging phenomenon. As a test result, the effects for decreasing settlement and promoting consolidation by GCP were prominent, and the mixed clay was not monitored in all of the three compaction piles.

  • PDF

A Study on the Behavior of Soft Clay Foundation Reinforced with Soil Cement Piles by Centrifugal Model Tests (원심모형실험에 의한 시멘트 개량말뚝으로 보강된 연약점토지반의 거동에 관한 연구)

  • Lee, Cheo-Keun;Shin, Bang-Woong;Heo, Yol;Ahn, Sang-Ro
    • Geotechnical Engineering
    • /
    • v.10 no.2
    • /
    • pp.109-120
    • /
    • 1994
  • One of problems being faced during construction of soil structures along the coastal regions is the stabilization of soft clay foundation, In this study, centrifugal model bests were conducted to investigate behavior effect of soft foundation reinforced by cement -soil piles for the stabilization of softs clay foundation during the embankment construction. This paper presents results of settlement and heaving behavior of reinforced and unreinforced foundation with time under the swaged loading for different best conditions. The test results have shown that the reductions of vertical settlement of the foundation and heaving of the ground surface adjacent to the embankment are greatly influenced by strength of improved pile, and moisture content, and especially the ratio of replacement area.

  • PDF

A Study on the Effectiveness of the Mortar Jet Method in Increasing the Strength of the Soft Ground (시멘트 몰탈형 고압분사공법(MJM)에 의한 연약지반 보강효과에 관한 연구)

  • Chun, Byung-Sik;Baek, Ki-Hyun;Jooi, Tae-Seong;Do, Jong-Nam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.59-64
    • /
    • 2005
  • Although high pressure discharge method is widely used for improving soft ground, it has various problems including lack of strength increase and the possibility of water pollution and soil contamination. MJM(Morta Jet Method) uses sand in addition to cement as the injection material. MJM uses triple rods with a built-in nozzle that allows easier discharge of the slime, resulting in higher replacement area ratio and more uniform formation of pillar hydrates, and thus results in significant increase in strength. MJM is expected to perform especially well as piles in marine clays. This study investigates the field applicability of the MJM through extensive laboratory and field tests.

  • PDF

Behavior of sand columns reinforced by vertical geotextile encasement and horizontal geotextile layers

  • Shamsi, Mohammad;Ghanbari, Ali;Nazariafshar, Javad
    • Geomechanics and Engineering
    • /
    • v.19 no.4
    • /
    • pp.329-342
    • /
    • 2019
  • In this paper, the effect of a group of sand columns in the loose soil bed using triaxial tests was studied. To investigate the effect of geotextile reinforcement type on the bearing capacity of these sand columns, Vertical encased sand columns (VESCs) and horizontally reinforced sand columns (HRSCs) were used. Number of sixteen independent triaxial tests and finite element simulation were performed on specimens with a diameter of 100 mm and a height of 200 mm. Specimens were reinforced by either a single sand column or three sand columns with the same area replacement ratio (16%) to evaluate the Influence of the column arrangement. Effect the number of sand columns, the length of vertical encasement and the number of horizontal reinforcing layers were investigated, in terms of bearing capacity improvement and economy. The results indicated that the ultimate bearing capacity of the samples with three ordinary sand columns (OSCs) is eventually about 11% more than samples with an OSC. Also, comparison of the column reinforcing modes showed that four horizontal layers of geotextile achieved similar performance to a vertical encasement geotextile at the 50% of the column height, from the viewpoint of strength improvement, while from the viewpoint of economy, the geotextile needed for encasing the single column is around 2.5 times of the geotextile required for four layers.

Numerical modelling of circular reinforced concrete columns confined with GFRP spirals using fracture-plastic model

  • Muhammad Saad Ifrahim;Abdul Jabbar Sangi;Shuaib H. Ahmad
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.527-536
    • /
    • 2023
  • Fiber Reinforced Polymer (FRP) bar has emerged as a viable and sustainable replacement to steel in reinforced concrete (RC) under severe corrosive environment. The behavior of concrete columns reinforced with FRP bars, spirals, and hoops is an ongoing area of research. In this study, 3D nonlinear numerical modelling of circular concrete columns reinforced with Glass Fiber Reinforced Polymer (GFRP) bars and transversely confined with GFRP spirals were conducted using fracture-plastic model. The numerical models and experimental results are found to be in good agreement. The effectiveness of confinement was accessed through von-mises stresses, and it was found that the stresses in the concrete's core are higher with a 30 mm pitch (46 MPa) compared to a 60 mm pitch (36 MPa). The validated models are used to conduct parametric studies. In terms of axial load carrying capacity and member ductility, the effect of concrete strength, spiral pitch, and longitudinal reinforcement ratio are thoroughly investigated. The confinement effect and member ductility of a GFRP RC column increases as the spiral pitch decreases. It is also found that the confinement effect and member ductility decreased with increase in strength of concrete.

Data allocation and Replacement Method based on The Access Frequency for Improving The Performance of SSD (SSD의 성능향상을 위한 접근빈도에 따른 데이터 할당 및 교체기법)

  • Yang, Yu-Seok;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.5
    • /
    • pp.74-82
    • /
    • 2011
  • SSD has a limitation of number of erase/write cycles and does not allow in-place update unlike the hard disk because SSD is composed of an array of NAND flash memory. Thus, FTL is used to effectively manage SSD of having different characteristics from traditional disk. FTL has page, block, log-block mapping method. Among then, when log-block mapping method such as BAST and FAST is used, the performance of SSD is degraded because frequent merge operations cause lots of pages to be copied and deleted. This paper proposes a data allocation and replacement method based on access frequency by allocating PRAM as checking area of access frequency, log blocks, storing region of hot data in SSD. The proposed method can enhance the performance and lifetime of SSD by storing cold data to flash memory and storing log blocks and frequently accessed data to PRAM and then reducing merge and erase operations. Besides, a data replacement method is used to increase utilization of PRAM which has limitation of capacity. The experimental results show that the ratio of erase operations of the proposed method is 46%, 38% smaller than those of BAST and FAST and the write performance of the proposed method is 34%, 19% higher than those of BAST and FAST, and the read performance of the proposed method is 5%, 3% higher than those of BAST and FAST, respectively.

Hypoalbuminemia and Albumin Replacement during Extracorporeal Membrane Oxygenation in Patients with Cardiogenic Shock

  • Jae Beom Jeon;Cho Hee Lee;Yongwhan Lim;Min-Chul Kim;Hwa Jin Cho;Do Wan Kim;Kyo Seon Lee;In Seok Jeong
    • Journal of Chest Surgery
    • /
    • v.56 no.4
    • /
    • pp.244-251
    • /
    • 2023
  • Background: Extracorporeal membrane oxygenation (ECMO) has been widely used in patients with cardiorespiratory failure. The serum albumin level is an important prognostic marker in critically ill patients. We evaluated the efficacy of using pre-ECMO serum albumin levels to predict 30-day mortality in patients with cardiogenic shock (CS) who underwent venoarterial (VA) ECMO. Methods: We reviewed the medical records of 114 adult patients who underwent VA-ECMO between March 2021 and September 2022. The patients were divided into survivors and non-survivors. Clinical data before and during ECMO were compared. Results: Patients' mean age was 67.8±13.6 years, and 36 (31.6%) were female. The proportion of survival to discharge was 48.6% (n=56). Cox regression analysis showed that the pre-ECMO albumin level independently predicted 30-day mortality (hazard ratio, 0.25; 95% confidence interval [CI], 0.11-0.59; p=0.002). The area under the receiver operating characteristic curve of albumin levels (pre-ECMO) was 0.73 (standard error [SE], 0.05; 95% CI, 0.63-0.81; p<0.001; cut-off value=3.4 g/dL). Kaplan-Meier survival analysis showed that the cumulative 30-day mortality was significantly higher in patients with a pre-ECMO albumin level ≤3.4 g/dL than in those with a level >3.4 g/dL (68.9% vs. 23.8%, p<0.001). As the adjusted amount of albumin infused increased, the possibility of 30-day mortality also increased (coefficient=0.140; SE, 0.037; p<0.001). Conclusion: Hypoalbuminemia during ECMO was associated with higher mortality, even with higher amounts of albumin replacement, in patients with CS who underwent VA-ECMO. Further studies are needed to predict the timing of albumin replacement during ECMO.