• Title/Summary/Keyword: area measurement

Search Result 3,984, Processing Time 0.03 seconds

An Analysis of Pre-Service Teachers' Mathematical Content Knowledge about the Area of a Circle (예비교사의 원의 넓이에 대한 내용지식 분석)

  • Choi, Eun Ah;Kang, Hyangim
    • School Mathematics
    • /
    • v.16 no.4
    • /
    • pp.763-782
    • /
    • 2014
  • The purpose of this study is to investigate mathematics content knowledge(MCK) of pre-service teachers about the area of a circle. 53 pre-service teachers were asked to perform four tasks based on the central ideas of measurement for the area of a circle. The results of this study are as follows. First, pre-service teachers had some difficulty in describing the meaning of the area of a circle. Quite a few of them didn't recognize the necessity of counting the number of area units. Secondly, pre-service teachers had insufficient content knowledge about the central ideas of measurement for the area of a circle such as partitioning, unit iteration, rearranging, structuring an array and approximation. Lastly, few pre-service teachers understood the concept of actual infinity. Most students regarded the rectangle as the figure having the approximation error instead of the limitation from rearranging the parts of a circle.

  • PDF

An Analysis on the status of Measurement Investment in Korean Industry (한국산업의 계측투자실태분석)

  • Kim, Dong-Jin;Nam, Gyeong-Hui
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.76-93
    • /
    • 1992
  • The purpose of this study, by surveying the status of firms, measurement-related investment and the defect rate, is to analyze the effect of measurement-related investment and to propose a scheme of efficient measurement-related investment which reduces the defect rate. For this project we obtain the data of the status of the measurement-related investment and the defect rate of 928 firms in Korean manufacturing industry by mailing survey. One of our results shows that the firms which have measurement standard laboratory, i.e, which invest in measurement-related area comparatively high, have the defect rate about 0.8% lower than those firms which don't have measurement standard laboratory. Also we find that the small-and-middle size firms have worse measurement-related facility than the large firms and the firms in the heavy-chemical industry have higher measurement-related investment effect than the firms in the light industry.

  • PDF

Distribution of Culturable Bacteria of Bioaerosol according to Land Type in Winter in the City Center (도심지 겨울철 토지피복 유형별 바이오에어로졸 중 배양성 세균 분포)

  • Kim, Jeong-Ho;Yun, Yong-Han;Kim, Hak-Gi;Lee, Myeong-Hun;Park, Yeong-jin;Lee, Dong-Jae;Sin, Yong-jin
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.6
    • /
    • pp.669-678
    • /
    • 2021
  • This study surveyed three land cover types in Chungju City in Chungcheongbuk Province to check the distribution of cultured bacteria in bio-aerosols according to land cover type. It was possible to compare and analyze the distribution of bacteria according to microclimatic changes at each measurement point by examining meteorological factors and bio-aerosols according to land cover. The microclimate temperature in each measurement point was 8.7℃ for the urban forest, 10.8℃ for the waterside green area, and 10.2℃ for the urban area, indicating the urban forest had the lowest temperature among the measurement points. The relative humanity was 61.8% fin the urban forest, 59.3% in the waterside green area, and 55.7% in the urban area, indicating that the urban forest was the most humid among the measurement points. The identified bacteria were found to be 43 genera and 99 species. In terms of species diversity of cultured bacteria, 22 genera were found in the waterside green area, 21 genera in the urban forest, and 17 genera in the urban area, 37 species were found in the waterside green area, 31 species in the urban area, and 31 species in the urban forest. Bacillus toyonensis and Pseudarthrobacter oxydan were the species present in all three types of measurement sites, and Herbiconiux flava was confirmed to inhabit green areas such as urban forests and waterside green areas. The analysis result of the bacterial concentration according to the microclimatic environment in each measurement point was 333 CFU/m3 in the urban forest, 287 CFU/m3, in the waterside green area, and 173 CFU/m3 in the downtown area. The relative humidity and wind speed were analyzed to show a similar trend as the concentration. This study is expected to provide basic data for healthy urban management and green area creation by identifying the distribution of cultured bacteria in bio-aerosols according to land cover type and comparing and analyzing the traits of bio-aerosol in each measurement point.

Stydy of Pool Boiling under Steady State using Ultrasonic Measurement (초음파 측정법을 이용한 정상상태의 푸울비등 연구)

  • 장길홍
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.35-40
    • /
    • 1992
  • A recently developed new technique for measuring the fraction of wetted area has applied to pool boiling of water. The basis of the new applied technique of ultrasonic makes use of the reflection of ultrasonic from the vapour surface to measure the fraction of wetted area values. The results are the measured fraction of wetted area values in nucleate and transition boiling and the pool boiling curve for water under steady state conditions. The measurement of this paper shows a fraction of wetted areaf around 0.98 at the critical heat flux for water.

  • PDF

Real Time Wide Area Voltage Stability Index in the Korean Metropolitan Area

  • Han, Sang-Wook;Lee, Byong-Jun;Kim, Sang-Tae;Moon, Young-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.451-456
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability has become one of the achievements we can obtain from PMUs. It is very important to select the most appropriate method for the Korea Electric Power Corporation (KEPCO) system since there are many voltage stability indices. In this paper, we propose an advanced WAVI (Wide Area Voltage Stability) that is well suited for the purposes of monitoring the dynamic voltage stability of KEPCO's PMU installation plan. The salient features of the proposed index are: i) it uses only PMU measurements without coupling with EMS data; ii) it is computationally unburdened and can be applied to real-time situations. The proposed index is applied to the KEPCO test system and the results show that it successfully predicts voltage instability through comparative studies.

A Study on the Use of Photogrammetry in Survey and Recording of Modern Architectural Properties (근대건축문화재 기록에서의 사진실측기법 활용)

  • Kwon, Soon-Chan
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.2
    • /
    • pp.9-16
    • /
    • 2013
  • This paper is to discover how the photogrammetry method can be utilized for recording modern architectural properties. As a result of conducting photogrammetry aimed at the main building and water supply tower of Goesan Middle School, it was possible to measure actually either complicated patterns or a damaged area on the facade. However, there appeared errors in the actual measurement of the hollow or protruded area on the facade to measure actually or of an object in the cylinder form. First, for the actual measurement of the protruded area, it is possible to complete a facade by measuring actually the protruded area separately after dividing it and complementing it on the facade, Second, concerning an object in the cylinder form, it is possible to complete one facade by matching a facade which is measured actually with a Diaver method among the MSR photogrammetry methods, and three dimensional standard coordinates which are obtained through Totalstation.

CHARACTERISTICS OF RESIDUAL CARBON DERIVED FROM THE COMBUSTION OF VACUUM RESIDUE IN A TEST FURNACE

  • Park, Ho-Young;Seo, Sang-Il
    • Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 2007
  • The characteristics of carbonaceous particles collected from the combustion of Vacuum Residue (VR) in a test furnace have been investigated. The physical and chemical characterization includes particle size, scanning electron microscopy of the surface structure, measurement of porosity, surface area and density, EDX/XRD analyses and measurement of chemical composition. The studies show that the carbonaceous VR particles are very porous and spheroidal, and have many blow-holes on the surface. The particles become smaller and more sponge-like as the reaction proceeds. The present porosity of VR particles is similar to that of cenospheres from the combustion of heavy oil, and the majority of pores are distributed in macro-pores above $0.03\;{\mu}m$ in diameter. Measurements of pore distribution and surface area showed that the macro-pores contributed most to total pore volume, whereas the micro-pores contributed to total surface area.

Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement (대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가)

  • Jeon, Eui-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

Study on Freak Wave Characteristics and Approximation of Wave Spectrum in Uljin Sea Area (울진해역의 Freak wave 특성과 스펙트럼 근사에 대한 연구)

  • Ryu, Hwang-Jin;Hong, Sa-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.8-13
    • /
    • 2012
  • This paper investigates the statistical properties of waves in the sea area of Uljin, which is located in the East Sea area of Korea. The wave data were measured using AWAC (Acoustic Wave and Current Meter), which was installed at a 16-m water depth from November 2010 to March 2011. The wave data acquisition rate, Hmax, monthly mean Hs, Tz, Tp, and wave direction are summarized. The distributions of Hs and Tz were analyzed using the Hs-Tz scatter diagrams. The measurement wave data were analyzed to investigate freak wave characteristics. By comparing the wave spectrum using the measurement wave data with the wave spectrum obtained by varying the JONSWAP wave spectrum, it was possible to approximate the wave spectrum shape at the Uljin Sea area.

A Study on Determination of the Area Function of Nano Indenter Tip with AFM (AFM을 이용한 나노 인덴터 팁의 면적함수 결정에 관한 연구)

  • 박성조;이현우;한승우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.145-152
    • /
    • 2004
  • Depth-sensing indentation is wifely used for evaluation of mechanical properties of thin films. It is generally accepted that the most significant source of uncertainty in nanoindentation measurement is the geometry of the indenter tip. Therefore the successful application of the technique requires accurate calibration of the indenter tip geometry. The direct measurement of geometry of a Berkovich indenter was determined using a atomic force microscope. The indentation geometrical calibration of contact area was performed by analyzing the indenter tip profile. The equations of area functions were proposed for nanoscale thin films..