• 제목/요약/키워드: area calculation

검색결과 1,540건 처리시간 0.036초

새만금 주변지역의 중심기능 분석 (Central Function Analysis in the Saemangeum Area)

  • 최수명;김홍균;박용진
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.115-118
    • /
    • 2003
  • This study was carried out to analyse the central functions of district-load areas (Eup or Myon in Korea) in the neighbourhood zone of Saemankeum Reclamation Area. From the calculation results of their functional indices, only 4 areas were selected as the second-order centers, while remaining 12 areas as the third-order centers. (key villages)

  • PDF

ADSL용 4D TCM Decoder 저전력 구조 설계 연구 (A low-power VLSI architecture of 4D TCM decoder for ADSL)

  • 이금형;김재석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.871-874
    • /
    • 1999
  • We propose a low complexity M-D(multidimensional) TCM decoder VLSI architecture for ADSL System. We use the shared subset decoder module by modifying the whole decoding procedure. We reduce power consumption by using the MSA (modulo set area) operation, which removes multiplication in 4D metric calculation. Also the proposed TCM decoder reduces chip area. It can be adopted in high-speed xDSL system.

  • PDF

UAV를 활용한 건물철거 지역 변화탐지 (Change Detection of Building Demolition Area Using UAV)

  • 신동윤;김태헌;한유경;김성삼;박제성
    • 대한원격탐사학회지
    • /
    • 제35권5_2호
    • /
    • pp.819-829
    • /
    • 2019
  • 붕괴사고가 발생하였을 시, 피해악화를 방지하기 위해 즉각적인 대응이 필요하며 피해면적 산출, 대응 및 복구 계획 수립 등이 이루어져야 한다. 이를 위해선 피해지역에 대한 정확한 탐지가 이루어져야 한다. 본 연구는 붕괴사고 피해탐지를 위해 신속하고 실시간 대응이 가능한 Unmanned Aerial Vehicle(UAV)를 활용하여 피해지역 탐지를 수행하였다. 연구대상지역은 재개발 사업이 착수되면서 주택 및 아파트의 철거가 진행 중에 있는 울산 중구 B-05 주택재개발 지역으로 선정하였다. 이 지역은 건물의 철거 모습이 붕괴된 상태와 유사하고 철거 전후의 변화가 뚜렷하게 나타나 있으며, 2019년 5월 17일, 7월 9일 각각 UAV 영상을 획득하였다. 건물의 붕괴 전후 영상에서 변화지역을 피해지역으로 판단하였으며, 이를 위해 대표적인 변화탐지 기법인 분광벡터 변화분석 기법(Change Vector Analysis)과 SLIC(Simple Linear Iterative Clustering)기반 superpixel 기법을 이용하였다. 피해지역을 정확하게 탐지하기 위해 비관심지역(식생)을 ExG(Excess Green)를 이용하여 1차적으로 제거해주었고, 변화탐지가 된 객체들 중 면적으로 인한 오탐지가 된 객체들은 최소면적을 계산하여 최종적으로 제거해주었다. 그 결과 변화지역 탐지의 전체결과는 95.39%를 나타냈으며, 추후 붕괴사고에 대한 대응 및 복구대책 및 피해액 산출 등 다양한 자료로 활용할 수 있을 것으로 기대된다.

지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로 (A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권4호
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구 (A Numerical Study on the Effect of Volute Geometry on the Performance of Centrifugal Pump)

  • 김덕수;전상규;윤준용;최영석
    • 한국유체기계학회 논문집
    • /
    • 제9권2호
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the effects of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

Ray-Tracing Method를 이용한 일영면적 산정방식 고찰 (A Study on the Calculation of Overshadowing Area by Ray-Tracing Method)

  • 최정민;조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.36-41
    • /
    • 2011
  • Nowadays, the solar expose right is very important with people's life. Therefore, in calculating the sunshine hours, the point analysis and area analysis methods are used in previous studies. Previous two methods have merits and faults. Therefore, ray-tracing method is used as a alternative. Ray-tracing method is adopted by the software of Autodesk Ecotect which is a widely used program by the architectural company and academic university. In this study first, ray-tracing methodology is studied with how to calculate the overshadowing area and, secondly, the sensitivity of the two major factors, overshadowing accuracy and sky subdivision, is analyzed. With these results, appropriate application of the ray-tracing method is presented.

일반 치과의원의 공간계획에 관한 사례 연구 (A Case Study on the Space Planning of Dental Clinic)

  • 이재영;이영한
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.125-131
    • /
    • 2013
  • This is a study on space planning of dental clinic by case analysis of 30 dental clinics that were cons tructed or designed in metropolitan area in recent years, It is analyzed as the following, required basic or additional rooms according to size divisions of gross floor area, relationship of treatment chair number and floor area, ratio of gross floor area and waiting zone, medical treatment zone, supporting zone, management zone, and zoning planning, space types of medical treatment zone, etc. This study can be used as basic data for planning of dental clinic and related future researches.

볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구 (A Numerical Study on the effect of Volute Geometry on the Performance of Centrifugal Pump)

  • 김덕수;최영석;전상규;윤준용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.497-502
    • /
    • 2005
  • In this study. the effect of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate. the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

  • PDF

볼류트 단면적 변화가 원심펌프의 성능곡선에 미치는 영향 (Effect of Volute Area Distributions on the Performance Characteristic Curve of a Centrifugal Pump)

  • 김덕수;이경용;윤준용;최영석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.558-563
    • /
    • 2005
  • In this paper, the effect of volute area distribution on the performance characteristic curve of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequency required. In order to control the shutoff head of a pump, several volute area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the characteristic curve of a centrifugal pump can be controlled by modifying the area distribution with the same volute outlet area.

  • PDF

순간전압강하 가혹지역에 기반한 사고예방 대책 수립 (Establishment of Preventive Measures against Faults Based on the Area of Severity to Voltage Sags)

  • 박창현;이계병;이한상;윤동희
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1611-1617
    • /
    • 2015
  • This paper presents an effective approach for establishing countermeasures against voltage sags based on the concept of area of severity. In order to apply preventive measures against faults such as lightning arrester, overhead earth wires and so on, it is important to find optimal points for installing the preventive measures. The optimal points can be determined by the calculation of the area of severity(AOS) to voltage sags and the expected sag frequency per unit length of line. In this paper, an effective method to find optimal points to apply countermeasures against voltage sags is addressed with case studies.