• 제목/요약/키워드: arches

검색결과 351건 처리시간 0.028초

Validity of the Nielsen-type hanger arrangement in spatial arch bridges with straight decks

  • Mirian Canovas-Gonzalez;Juan M. Garcia-Guerrero;Juan J. Jorquera-Lucerga
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.51-69
    • /
    • 2023
  • In tied-arch bridges, a properly designed connection between the arch and the deck may become crucial, since the forces in the structure may be significantly reduced. This implies substantial material savings and, consequently, cheaper constructions. The introduction of the Nielsen cable arrangement (composed of V-shaped inclined hangers) in the last century was a milestone because it was able to reduce deflections and bending moments both in the arch and in the deck. So far, the Nielsen cable arrangement has proven to be successful in traditional vertical arch bridges. However, despite its advantages, it has not been widely applied to spatial arch bridges. Thus, this article analyses the difference between the structural behavior of spatial arch bridges with Nielsen-type cable arrangements with respect to those with classical vertical hanger configurations. The main goal is to verify whether the known effectiveness of the Nielsen cable arrangement for classical arch bridges is still preserved when applied to spatial arch bridges. In order to achieve this objective, and as the first part of our study, a set of different all-steel bridges composed of vertical and inclined arches with straight decks have been compared for both cable arrangements. As a major conclusion, for planar vertical arch bridges, the Nielsen-type cable arrangement is always the most effective. In addition, it also seems that, for spatial arch bridges composed of a straight deck and an inclined arch, it still keeps most of its effectiveness as long as the arch is moderately inclined.

A novel method for testing accuracy of bite registration using intraoral scanners

  • Lydia Kakali;Demetrios J. Halazonetis
    • 대한치과교정학회지
    • /
    • 제53권4호
    • /
    • pp.254-263
    • /
    • 2023
  • Objective: The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners. Methods: Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch. Results: The average maximum error in interocclusal registration exceeded 50 ㎛. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 ㎛ or more. The models with acrylic teeth exhibited higher errors. Conclusions: A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.

The tunnel model tests of material development in different surrounding rock grades and the force laws in whole excavation-support processes

  • Jian Zhou;Zhi Ding;Jinkun Huang;Xinan Yang;Mingjie Ma
    • Geomechanics and Engineering
    • /
    • 제36권1호
    • /
    • pp.51-69
    • /
    • 2024
  • Currently, composite lining mountain tunnels in China are generally classified based on the [BQ] method for the surrounding rock grade. Increasingly, tunnel field construction is replicated indoors for scale down model tests. However, the development of analogous materials for model tests of composite lining tunnels with different surrounding rock grades is still unclear. In this study, typical Class III and V surrounding rock analogous materials and corresponding composite lining support materials were developed. The whole processes of excavation-support dynamics of the mountain tunnels were simulated. Data on the variation of deformations, contact pressures and strains on the surrounding rock were obtained. Finally, a comparative analysis between model tests and numerical simulations was performed to verify the rationality of analogous material development. The following useful conclusions were obtained by analyzing the data from the tests. The main analogous materials of Class III surrounding rock are barite powder, high-strength gypsum and quartz sand with fly ash, quartz sand, anhydrous ethanol and rosin for Class V surrounding rock. Analogous materials for rockbolts, steel arches are replaced by aluminum bar and iron bar respectively with both shotcrete and secondary lining corresponding to gypsum and water. In addition, load release rate of Class V surrounding rock should be less than Class III surrounding rock. The fenestration level had large influence on the load sharing ratio of the secondary lining, with a difference of more than 30%, while the influence of the support time was smaller. The Sharing ratios of secondary lining in Class III surrounding rock do not exceed 12%, while those of Class V surrounding rock exceed 40%. The overall difference between the results of model tests and numerical simulations is small, which verifies the feasibility of similar material development in this study.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

Study on bearing capacity of combined confined concrete arch in large-section tunnel

  • Jiang Bei;Xu Shuo;Wang Qi;Xin Zhong Xin;Wei Hua Yong;Ma Feng Lin
    • Steel and Composite Structures
    • /
    • 제51권2호
    • /
    • pp.117-126
    • /
    • 2024
  • There are many challenges in the construction of large-section tunnels, such as extremely soft rock and fractured zones. In order to solve these problems, the confined concrete support technology is proposed to control the surrounding rocks. The large-scale laboratory test is carried out to clarify mechanical behaviours of the combined confined concrete and traditional I-steel arches. The test results show that the bearing capacity of combined confined concrete arch is 3217.5 kN, which is 3.12 times that of the combined I-steel arch. The optimum design method is proposed to select reasonable design parameters for confined concrete arch. The parametric finite element (FE) analysis is carried out to study the effect of the design factors via optimum design method. The steel pipe wall thickness and the longitudinal connection ring spacing have a significant effect on the bearing capacity of the combined confined concrete arch. Based on the above research, the confined concrete support technology is applied on site. The field monitoring results shows that the arch has an excellent control effect on the surrounding rock deformation. The results of this research provide a reference for the support design of surrounding rocks in large-section tunnels.

완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적 (Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches)

  • 허윤혁;이양진;권민정;김영균;차민상
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.183-189
    • /
    • 2013
  • 연구 목적: 이 연구의 목적은 완전무치악 환자에서 임플란트 지지 고정성 하이브리드 수복물로 수복한 환자의 임상성적을 알아보는 것이다. 연구 대상 및 방법: 분당서울대병원에서 2003년 10월부터 2009년 11월 사이에 4-6개의 임플란트 지지 고정성 하이브리드 수복물로 수복을 하고 1년 이상 기능한 환자를 대상으로 하였다. 방사선 사진상에서 변연골 흡수량을 측정하고 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기, 식립 경사도에 따른 차이를 비모수 검정(Mann-Whitney U test) 하고, 외팔보의 길이에 따른 영향을 회귀분석하였으며 합병증을 조사하였다. 유의 수준P<.05로 검정하였다. 결과: 총 16명, 16개 수복물에서 84개의 임플란트의 평균 28개월 후의 골흡수량은 $0.53{\pm}0.39mm$였다. 환자의 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기에 따른 골흡수량의 유의차는 관찰되지 않았으며(P>.05) 회귀분석 결과 외팔보의 길이와 외팔보 인접 최후방 임플란트의 골흡수량 사이에도 유의성이 없었다(P>.05). 16명중11명의 환자에서 합병증이 발생하였으며 전장재 파절과 인공치 탈락이 가장 많았다. 결론: 짧은 기간의 후향적 연구라는 한계 내에서, 임플란트 지지 고정성 하이브리드 수복물의 평균 골흡수는 매우 적었지만 높은 빈도의 합병증 발생을 보였다. 외팔보 인접 최후방 임플란트의 경사와 관계 없이 외팔보 인접 최후방 임플란트보다 나머지 전방부 임플란트의 변연골 흡수량이 유의하게 컸다. 모든 증례의 외팔보 길이(< 17 mm)는 외팔보 인접 최후방 임플란트 변연골 흡수량에 영향을 주지 않았다.

참복과(복어목) 어류의 속별 척추골과 담기골 특징 (Generic Characters of Vertebrae and Pterygiophore of the Fishes of the Family Tetraodontidae (Teleostei: Tetraodontiformes))

  • 한경호;김용억
    • 한국수산과학회지
    • /
    • 제31권5호
    • /
    • pp.645-653
    • /
    • 1998
  • 참복과 (Tetraodontidae) 어류의 형태와 골격 및 분류를 연구하기 위하여, 1991년 3월부터 1994년 3월까지 우리나라 20개 지점에서 10속 27종의 표본을 채집하여, 척추골 및 담기골의 형태에 대하여 조사하였다. 1. 참복과 어류의 척추골수는 밀복속(Lagocephalus), 은띠복속 (Pleurancanthus), 불룩복속 (Spheoides), 꺼끌복 속(Arothron), 첼로복속(Chelonoeon) 및 청복속(Canthigaster)이 17$\~$19개이며, 수지복속(Ephippion), 별복속 (Boesemanichthys) 및 대치복속(Feroxodon)의 어류는 20개이고, 반면에 참복속(Takifugu) 어류는 19$\~$25개였다. 2. 참복과 어류의 척추골수는 17$\~$25개로, 밀복속의 밀복 (L. lunaris과 은띠복속의 은띠복 (P. sceleatus), 청복속 등이 17개로 최소치를, 참복속의 황복 (T. obscurus)이 24$\~$25개로 복어과 가운데 최대치를 보였다. 3. 밀복속의 척추골수는 밀복이 17개, 민밀복 (L. inermis)이 18개, 흑밀복 (L. gloveri), 은밀복 (L. wheeleri) 및 은민밀복 (L. larigatus)이 19개로 다른 속 어류들 보다 적은 수의 척추골을 가지고 있는 점에서 더 분화되어 있다. 4. 척추골 가운데 복추골의 신경극이 참복속의 졸복(T. pardalis)과 황복이 제$1\~5$번째 척추골의 신경극까지 쌍으로 되어 있고, 나머지 다른 종과 속 어류들은 제1$\~$4 번째 척추골의 신경극이 쌍으로 되어 있다. 5. 밀복속과 은띠복속의 큰 특징은 등쪽과 배쪽 담기골에 뒷 돌기가 있으며, 상미축골 (epural)이 넓은 판 모양이고, 복추골의 혈관극에 돌기가 없는 점에서 다른 속과 쉽게 구별된다. 6. 은띠복속의 은띠복은 꼬리자루 부분이 날씬하고 측편되어 있어서, 미추골 뒷부분의 신경극과 혈관극이 다른 속 어류와 비교해 짧은 점에서 구별된다 7. 청복속은 등지느러미와 뒷지느러미를 지지하는 제1 담기골이 다른 속에 비하여 매우 비대하여 큰 편이다. 또한 복추골의 뒷부분에 혈관극과 혈관궁이 둥글고 판판하게 잘 발달되어 참복과의 다른 속과 큰 차이를 보였다.

  • PDF

전부 피개관의 치아 형성 시 축면 경사각에 대한 조사 (Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns)

  • 김성진;배아란;우이형;김형섭
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.21-32
    • /
    • 2010
  • 삭제된 치아의 경사도는 치관 수복물의 유지와 저항에 있어 매우 중요한 요소이다. 하지만 다양한 구강 내 환경과 술자의 능력에 따라 이상적인 경사도를 얻는 것은 쉽지 않다. 따라서 이상적으로 삭제된 치아의 경사도와 실제 임상에서 삭제된 치아의 경사도를 조사하고자 한다. 본 실험의 연구 자료는 K대학 부속 치과병원 중앙 기공실을 통하여 보철과 전공의가 시술한 환자의 모형과 일반 기공소를 통해 일반 개업의가 시술한 환자의 모형을 수집한다. 연구 방법은 각 치아의 근원심면과 협설면을 디지털 카메라를 통해 촬영한 뒤 'ImageJ' 프로그램 상에서 치아의 삭제 각도를 측정 한 뒤 항목별( 1. 술자 집단별 분류, 2. 치열궁 내에서의 위치에 따른 분류, 3. 삭제 양식에 따른 분류 )로 분류하여 비교 분석한다. 이번 연구를 통해 조사한 결과 국내 임상가의 지대치 형성시 축면 경사각의 평균은 $15.02^{\circ}$ 표준 편차는 ${\pm}10.13^{\circ}$였다. 1. 술자 집단별 분류에 대한 분석 일반 치과의 집단의 측면 경사각과 보철과 전공의 집단의 축면 경사각에서 유의성 있는 차이를 보였다(p<0.05). 2. 치열궁 내에서의 위치에 따른 분석 치아의 근원심면과 협설측면에 따라 일반 치과의 집단의 경우 유의성 있는 차이가 없었으며(p>0.05) 보철과 전공의 집단에서는 유의성 있는 차이를 보였다(p<0.05). 치아의 전후적인 위치에 따라 일반 치과의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며 (p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며(p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 상악과 하악으로 분류하여 분석한 경우 일반 치과의 집단에서 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단에서도 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 악궁을 좌측과 우측으로 분류하여 분석한 경우 일반 치과의 집단과 보철과 전공의 집단에서 각각 유의성 있는 차이가 없었다(p>0.05). 3. 삭제 양식에 따른 분석 단일 치관을 위한 지대치와 3본 고정성 부분 의치를 위한 지대치로 분류하여 분석한 결과 일반 치과의 집단에서 근원심면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이를 보였으며(p<0.05) 협설측면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이가 없었다(p>0.05). 보철과 전공의 집단에서는 협설측면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이가 없었으며(p>0.05) 근원심면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이를 보였다(p<0.05). 이상에서 임상에서 치아 삭제시 이상적인 축면 경사각을 얻기 힘들며 이는 술자의 경험과 악궁 내에서의 위치, 삭제 양식에 따라 영향을 받을 수 있다.

생쥐 배자발생초기의 세포자기사 발현 양상에 관한 연구 (TEMPOROSPATIAL PATTERNS OF PROGRAMMED CELL DEATH DURING EARLY DEVELOPMENT OF THE MOUSE EMBRYOS)

  • 백병주;이승익;김재곤;박병용;박병건
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.709-727
    • /
    • 2001
  • 세포자기사(programmed cell death)는 배자발생과정에서 중요한 역할을 하는 정상적인 생리적현상으로 알려져왔다. 생쥐 배자에서 세포자기사에 관한 많은 연구가 있었지만 초기 형태발생기동안의 전반적이고 구체적인 세포자기사 양상에 관한 보고는 없었다. 이에 본 연구에서는 발생 4.5일$\sim$11.5일째의 Balb/c생쥐배자에서 생쥐발생초기의 세포자기사가 일어나는 양상을 알아보았다. 세포자기사가 일어나는 양상은 배자 조직절편과 온전한 배자에 in situ terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) 반응을 시켜 알아보았다. 주머니포배시기 (발생 4.5일째)에는 세포자기사 과정에 있는 세포가 극히 드물게 속세포명이에서 관찰되었다. Egg cylinder시기 초기(발생 $5.0\sim5.5$일째)에는 소수의 세포자기사 세포가 배자외배엽과 배자내배엽, 원시양막공간에서 나타났다. Egg cylinder시기 후반부(발생 $5.5\sim6.5$일)에는 세포자기사 세포가 배자외배엽, 배자내배엽, 원시양막공간 뿐만 아니라 바깥배자외배엽과 바깥배자내배엽 에서도 관찰되었다. Streak 시기 (발생 $6.75\sim7.75$일)에는 많은 세포자기사 세포가 ectoplacental cone부위에서 관찰된 반면에, 배자바깥 부위에서는 융모막과 바깥배자내배엽에서 매우 적은 수의 세포자기사 세포가 관찰되었고, 배자부위에서는 소수의 세포자기사 세포가 무작위적으로 배자외배엽과 중배엽, 그리고 배자내배엽 부위에서 관찰되었다. 체절형성기 초기 (발생 $8.0\sim8.5$일)에는 많은 수의 세포자기사 세포가 신경주름(neural fold)의 가장 앞쪽(머리쪽)에 주로 분포하는 것이 관찰되었다. 체절형성기 중기(발생 $9.0\sim9.5$일)에 귀기원판(otic placode)부위에서 처음으로 세포자기사 세포가 관찰되었고, 적은 수의 세포자기사 세포들이 또한 눈기원판(optic placode)과 아가미궁에서도 관찰되기 시작하였다. 발생 $9.5\sim9.75$일째에 크게 세가지 흐름의 세포자기사 세포들이 머리쪽 부위에서 관찰되었다. 발생 10.5일째에는 세포자기사 세포들이 발생중인 눈 부위와 안쪽코돌기와 바깥쪽코돌기 그리고 상악돌기가 만나는 부위, 아가미궁의 가쪽부위, 양쪽 하악돌기가 만나는 중앙부위, 그리고 팔다리싹의 꼭대기외배엽능선에 국한되어 관찰되었다. 발생 11.5일째에는 세포자기사 세포가 발생중인 팔다리부위와 꼬리부위를 제외한 나머지 부위에서는 현저히 감소되어 나타났다. 본 연구에서는 생쥐 발생초기 동안에 나타나는 세포자기사 세포가 발생시기에 따라 어느 부위에 발현되는 가는 알아보았는데, 이러한 연구 결과는 배자의 형태발생을 연구하는데 기초적인 자료로 활용될 수 있을 것으로 사료된다.

  • PDF

효율개선을 위한 다중제어 인버터방식의 아치형 PV System 성능 분석 (The Arch Type PV System Performance Evaluation of Multi Controlled Inverter for Improve the Efficiency)

  • 이용미;박정민
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5452-5457
    • /
    • 2012
  • 태양전지를 실제적인 건물의 한 구성요소로 이용하는 건물일체형 태양광발전(BIPV : Building Integrated Photovoltaic) 시스템은 기존의 건물재료를 대체하여 재료비용 및 건설비용의 절감효과를 가져다주며 건물의 미적인 가치를 높여주는 장점을 가지고 있다. BIPV에 대한 연구가 유럽 및 미국, 일본 등의 나라에서 오래전부터 활발히 수행되고 있으며, 시장성 또한 무한 확대되고 있다. 아치형 PV 시스템은 PV 어레이의 직병렬 연결 상태 및 아치각에 따라 효율 특성이 상이하지만 이에 관한 분석은 미흡하며, 아치형 PV 시스템을 설계함에 있어서 미적인 요소만 고려하고 이러한 발전효율에 관한 요소는 전혀 고려되지 않은 채 설계되고 있다. 본 논문에서는 아치형 PV 시스템의 효율에 관한 파라미터인 위도와 경도, 온도 및 일사량, 아치각, 시스템 구성에 따른 각종 손실 등 이에 대한 세부적인 기술검토와 각 장비들의 특성을 정합시켜 아치형 PV 시스템의 최적화를 이루어 효율을 개선시키고자 한다. 아치형 PV 시스템의 효율개선을 위하여 다중제어 인버터 방식을 제안하고 시뮬레이션 툴인 Solar Pro를 이용하여 평판형 및 다양한 아치형 PV 시스템을 구성하여 운전특성을 비교 분석하였다.