• 제목/요약/키워드: arc-attenuation

검색결과 16건 처리시간 0.025초

개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험 (Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit)

  • 이성민;김효성
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

Thin-Section CT Findings of Arc-Welders' Pneumoconiosis

  • Daehee Han;Jin Mo Goo;Jung-Gi Im;Kyung Soo Lee;Do Myung Paek;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.79-83
    • /
    • 2000
  • Objective: To describe the thin-section CT findings of arc-welders' pneumoconiosis. Materials and Methods: Eighty-five arc-welders with a three to 30 (mean, 15)-year history of exposure underwent thin-section CT scanning. The extent of abnormalities detected was correlated with the severity of dyspnea and pulmonary function tests. For comparison, images of 43 smoking males (mean 25 pack-year) who underwent thin-section CT for other reasons (smokers' group) were also analyzed. Results: Fifty-four welders (63.5%) and six smokers (14.0%) showed positive findings. Predominant thin-section CT findings were poorly-defined centrilobular micronodules (30/54, 55.6%), branching linear structure (18/54, 33.3%), and ground-glass attenuation (6/54, 11.1%). In the smokers' group, poorly-defined micronodules were found in four patients, branching linear structures in one, and ground-glass attenuation in one. In welders, the extent of abnormalities seen on thin-section CT showed no significant correlation with the severity of dyspnea or the results of pulmonary funotion test. Conclusion: Poorly-defined centrilobular micronodules and branching linear structures were the thin-section CT findings most frequently seen in patients with arc-welders' pneumoconiosis. Less commonly, extensive ground-glass attenuation was also seen.

  • PDF

지진에 대한 사면의 재해위험지도 작성 - 울산시 울주군 지역을 중심으로- (Seismic Landslide Hazard Maps in Ul-Ju Ul-san Korea)

  • 조성원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.89-96
    • /
    • 2000
  • Landslide damage comprise most part of the damages from the earthquake and it only causes the damage to lives and structures directly but also cease the operation of social system by road or lifeline failure. For these reasons hazard assesment on the landslides has been recognized very important. And hazard maps have been used to visualize the hazard of the landslide. In this study as first step for application of hazard map to domestic cases hazard maps are made for the Ul-Joo Ul-san Korea, Where the Yan-san faults are located. For building hazard maps the degree of hazard are evaluated based on Newmark displacement and the resulting maps are constructed by GIS technique. In hazard assesment maximum ground acceleration obtained from attenuation equation of wave propagation and design earthquake acceleration suggested by Ministry of construction are used for acceleration term. Hazard maps are made by GIS programs Arc/Info and Arc/View based on the digital maps and data from lab tests and elastic wave surveys The maps show the possible landslide regions significantly and the displacements of slide are proportional to the slope angles.

  • PDF

초전도 마그네트 시스템 내부 아크방전에 의한 발생 서어지의 전파특성 (Propagation Characteristics of Surge Generated due to Internal Arc Discharge in Superconducting Magnet)

  • 최병주;말광 순야;원아칙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1904-1906
    • /
    • 1996
  • Transient voltage distribution tests are carried out to evaluate effects of a high frequency oscillating voltage generated in a superconducting magnet as a result of the arc discharge extinction. Especially, the effects of temperature and conduction state of the magnet conductor on surge behavior are carefully investigated. Based on the results of simulation tests, it is shown that internal voltage waveforms are influenced by its transmission along the superconducting wire and reflection at the terminal and that attenuation process of the waveforms depends considerably on the conductor resistance which decreases with lowering the temperature.

  • PDF

감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구 (The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation)

  • 전춘생
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험 (Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-attenuation Circuit)

  • 이성민;유태식;김효성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.417-418
    • /
    • 2012
  • 최근 들어 디지털 제품의 급증으로 인해 직류를 사용하는 부하가 증가하고, 태양광, 풍력발전 등의 직류를 생산하는 신재생에너지원의 발달로 인하여 부하에 직류를 직접 공급 할 수 있게 되었다. 직류배전은 가전기기 내부의 전력 변환단계를 줄임으로써 교류배전에 비해 에너지 변환 효율을 높일 수 있는 장점이 있다. 하지만 직류는 교류와 다르게 고장 전류의 차단이 어렵다. 본 논문은 유도성 부하에서 효과적인 직류차단을 위한 자기소호회로와 아크전압 억제회로를 제안하고 실험을 통하여 그 효과를 검증하였다.

  • PDF

선형 위상 신호를 이용한 위상속도 측정에 관한 연구 (A Study on Phase Velocity Measurement using Linear Phase Signal)

  • 고덕영;김계국;이종악
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.51-54
    • /
    • 1988
  • In this paper, Digital signal processing method is deserved by the tissue characteristic quantization. Linear phase velocity is studied using linear signal, and the slope which attenuation characteristics are decreased is analysed according to frequency increase. A more efficient method determining the minimum phase function is developed from the spectral magnitud function.

  • PDF

Advances in Ultrasonic Testing of Austenitic Stainless Steel Welds

  • Moysan, J.;Ploix, M.A.;Corneloup, G.;Guy, P.;Guerjouma, R. El;Chassignole, B.
    • 비파괴검사학회지
    • /
    • 제28권3호
    • /
    • pp.245-253
    • /
    • 2008
  • A precise description of the material is a key point to obtain reliable results when using wave propagation codes. In the case of multipass welds, the material is very difficult to describe due to its anisotropic and heterogeneous properties. Two main advances are presented in the following. The first advance is a model which describes the anisotropy resulting from the metal solidification and thus the model reproduces an anisotropy that is correlated with the grain orientation. The model is called MINA for modelling anisotropy from Notebook of Arc welding. With this kind of material model1ing a good description of the behaviour of the wave propagation is obtained, such as beam deviation or even beam division. But another advance is also necessary to have a good amplitude prediction: a good quantification of the attenuation, particularly due to grain scattering, is also required as far as attenuation exhibits a strong anisotropic behaviour too. Measurement of attenuation is difficult to achieve in anisotropic materials. An experimental approach has been based both on the decomposition of experimental beams into plane waves angular spectra and on the propagation modelling through the anisotropic material via transmission coefficients computed in generally triclinic case. Various examples of results are showed and also some prospects to continue refining numerical simulation of wave propagation.

도시교통소음예측에 의한 주거지역 소음지도제작 (Noise Mapping of Residential Areas by Estimating Urban Traffic Noise)

  • 어재훈;유환희
    • 한국측량학회지
    • /
    • 제29권3호
    • /
    • pp.229-235
    • /
    • 2011
  • 교통소음공해가 도시생활에 있어서 건강에 중요한 영향을 주고 있으며 소음을 효과적으로 측정하기 위해 소음분포에 관한 소음지도제작은 매우 긴요한 일이 되고 있다. 도시교통소음지도는 소음을 조정하기 위한 효과적인 방안을 찾고 실질적인 근거를 마련하는데 도움을 주고 있으며, 소음이 도로로부터 주거지역으로 어떻게 전파되는지를 시각적으로 이해하기 쉽게 정보를 주고 있다. 본 연구에서는 도로와 거주지역간의 개발형태를 3가지로 구분하여 고려하였고, 주거지역내에서의 필지별 소음정도를 도로로부터 거리가 떨어짐에 따른 소음감쇄를 ArcGIS의 보간법을 적용하여 계산하고 그 결과를 이용하여 소음지도를 제작하였다. 그 결과 주거지역내의 교통 소음수준이 국내 환경기준을 초과하고 있음을 알 수 있었고, 각각의 필지별 소음수준을 추정할 수 있었다. 이것은 향후교통소음조정계획을 수립하거나 공시지가평가 시 활용될 수 있을 것으로 판단된다.

다공벽을 이용한 충격파 강도의 피동제어 (Passive control of strength of shock wave)

  • 최영상;권순범;조철영
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.174-184
    • /
    • 1997
  • A shock wave, being an irreversible process, gives rise to entropy increase. A great deal of effort has been made to control shock wave and boundary layer interaction related to energy losses as well as problems of vibration and noise. In the present study, tests are performed on a roof mounted half circular arc in an indraft type supersonic wind tunnel to evaluate the effects of porosity, length and depth of cavity in passive control of shock wave on the attenuation of shock strength by reviewing the measured static pressures at the porous wall and cavity. Also the flow field is visualized by a Schlieren system. The results show that in the present study the porosity of 8% produced the largest reduction of pressure fluctuations and that for the same porosity, the strength of shock wave decreases with the increasings of the depth and length of cavity.