가스차단기내 아크의 복사에너지 측정에 관한 연구 (Study on the Measurement of Radiation Energy of the Arc in GCBs)

  • 송기동;오연호;정진교;조용성
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.

A COMPARISON OF SIMULATION MODELS BASED ON ARC METABOLIZABLE ENERGY SYSTEM AND NRC NET ENERGY SYSTEM WITH SPECIAL REFERENCE TO GROWING STEERS

  • Hirooka, H.;Yamada, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제2권4호
    • /
    • pp.599-605
    • /
    • 1989
  • A comparison of the ARC metabolizable energy system and the NRC net energy system was made with special reference to growing steers. Two simulation models, one based on the ARC and other on the NRC system, were constructed to examine differences between the energy systems. The average daily live-weight gains predicted from both models for growing steers were compared under various conditions in which equal feeding levels and metabolizabilities were assumed. The two simulation models yielded similar results with very high energy intake with high quality feed. Difference between the two systems became larger as feeding conditions deviated from the above. The ARC system generally predicted higher daily live-weight gains than the NRC system. This appeared to be due to the higher efficiency of utilization of metabolizable energy ($k_m$ and $k_f$) and basal metabolism (F), and lower energy value of growth (EVG) in the ARC system.

50kW 태양광 설비의 아크 검출 알고리즘 개발 (Development of Arc Detection Algorithm for 50 kW Photovoltaic System)

  • 김상규;이창성;지평식
    • 전기학회논문지P
    • /
    • 제67권1호
    • /
    • pp.27-32
    • /
    • 2018
  • In this paper, we developed an algorithm to detect arc of PV power plant through frequency analysis. For arc detection based on frequency analysis, the filter should be designed to emphasize the difference between the arc state and the normal state. Therefore, in this paper, we analyzed the arc detection performance according to various filter structures. The arc detection algorithm developed in this paper extracts the filtering signal on current by using various filters and then calculates the frequency components and total energy using the FFT. In the final step, the arc is detected using the calculated energy magnitude. In order to verify the performance of the proposed arc detection algorithm, experiments were conducted on 51 kW solar inverters connected to power line. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

태양광 직렬 아크 검출기의 오검출 방지를 위한 DWT 기반 파라미터 및 반복 알고리즘 (DWT-Based Parameter and Iteration Algorithm for Preventing Arc False Detection in PV DC Arc Fault Detector)

  • 안재범;이진한;이진;류홍제
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.100-105
    • /
    • 2022
  • This paper applies the arc detection algorithm to prevent the false detection in photo voltaic series arc detection circuit, which is required not only to detect the series arc quickly, but also not falsely detect the arc for the non-arc noise. For this purpose, this study proposes a rapid and preventive false detection method of single peak noise and short noise signals. First, to prevent false detection by single peak noise, Discrete wavelet transform (DWT)-based characteristic parameters are applied to determine the shape and the amplitude of the noise. In addition, arc fault detection within a few milliseconds is performed with the DWT iterative algorithm to quickly prevent false detection for short noise signals, considering the continuity of serial arc noise. Thus, the method operates not only to detect series arc, but also to avoid false arc detection for peak and short noises. The proposed algorithm is applied to real-time serial arc detection circuit based on the TMS320F28335 DSP. The serial arc detection and peak noise filtering performances are verified in the built simulated arc test facility. Furthermore, the filtering performance of short noise generated through DC switch operation is confirmed.

발전소용 인버터에 의한 절전형 아크용접기에 관한 연구 (A Study on Inverter Arc Welder for Energy Saving in Power Station)

  • 윤병도;정재윤;김찬기;이병송
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권2호
    • /
    • pp.85-93
    • /
    • 1994
  • 본 논문에서는 절전형 인버터 아크용접기의 용접특성에 대하여 연구한다. 특히, 펄스아크와 고주파아크의 중첩이 연구되었다. 시뮬레이션과 실험결과에 따라 고주파 중첩아크가 에너지절감과 용접특성의 관점에서 다른 용접법에 비해서 우수함을 확인하였다.

  • PDF

릴레이 접점의 자기적 아크 저감 분석 (Analysis of Magnetic Arc Reduction of Relay Contacts)

  • 최순호;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제32권3호
    • /
    • pp.234-240
    • /
    • 2019
  • In this work, the magnetic arc reduction phenomena encountered in AC relay contacts were analyzed. To this end, arc duration, instantaneous voltage, and current changes due to changes in the magnetic field were observed. The arc generated at the contact point was affected by the magnitude of the applied magnetic field; the voltage and current waveforms rapidly intersected, resulting in a decrease in arc duration and arc energy. Furthermore, the orientation of the N pole of the magnetic field was found to play a role in the effectiveness of potential arc prevention.

태양광 직렬 아크 검출기의 검출 성능 및 DWT 알고리즘 연산 속도 개선 (Arc Detection Performance and Processing Speed Improvement of Discrete Wavelet Transform Algorithm for Photovoltaic Series Arc Fault Detector)

  • 조찬기;안재범;이진한;이기덕;이진;류홍제
    • 전력전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.32-37
    • /
    • 2021
  • This study proposes a DC series arc fault detector using a frequency analysis method called the discrete wavelet transform (DWT), in which the processing speed of the DWT algorithm is improved effectively. The processing time can be shortened because of the time characteristic of the DWT result. The performance of the developed DC series arc fault detector for a large photovoltaic system is verified with various DC series arc generation conditions. Successful DC series arc detection and improved calculation time were both demonstrated through the measured actual arc experimental result.

옥내배선 길이에 따른 단락 특성의 실험적 연구 (An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length)

  • 송재용;김진표;조영진;최돈묵;오부열;길경석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

DWT 및 고주파 노이즈 성분 분석을 이용한 PV 시스템 인버터 노이즈 구분 및 직렬 아크 검출 (Separation Inverter Noise and Detection of DC Series Arc in PV System Based on Discrete Wavelet Transform and High Frequency Noise Component Analysis)

  • 안재범;조현빈;이진한;조찬기;이기덕;이진;임승범;류홍제
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.271-276
    • /
    • 2021
  • Arc fault detector based on multilevel DWT with analysis of high-frequency noise components over 100 kHz is proposed in this study to improve the performance in detecting serial arcs and distinguishing them from inverter noise in PV systems. PV inverters generally operate at a frequency range of 20-50 kHz for switching operation and maximum power tracking control, and the effect of these frequency components on the signal for arc detection leads to negative arc detection. High-speed ADC and multilevel DWT are used in this study to analyze frequency components above 100 kHz. Such high frequency components are less influenced by inverter noise and utilized to detect as well as separate DC series arc from inverter noise. Arc detectors identify the input current of PV inverters using a Rogowski coil. The sensed signal is filtered, amplified, and used in 800kSPS ADC and DWT analysis and arc occurrence determination in DSP. An arc detection simulation facility in UL1699B was constructed and AFD tests the proposed detector were conducted to verify the performance of arc detection and performance of distinction of the negative arc. The satisfactory performance of the arc detector meets the standard of arc detection and extinguishing time of UL1699B with an arc detection time of approximately 0.11 seconds.

Modified FLIC법과 아크 모델을 이용한 차단기 내의 아크 유동 해석 (The Analysis of Arc-Flow Interaction in the GCB using the Modified FLIC Method and the Arc Model)

  • 신승록;김홍규;정현교
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.172-179
    • /
    • 2000
  • In this paper, the analysis of the arc-flow in the GCB is presented by using the modified FLIC method and the arc model. The modified FLIC method adopts the upwind scheme and requires short calculation time. The arc model used in this paper treats the arc as a energy source in the energy equation. The energy source is composed of the ohmic heating and the radiation energy transfer. At each step, the movement of electrode is simulated. From the simulation, reasonable results can be obtained.