• 제목/요약/키워드: applied load

검색결과 6,405건 처리시간 0.034초

모멘트 하중을 고려한 깊은 홈 볼 베어링의 정등가 하중에 관한 연구 (The Static Equivalent Radial Load under the Moment and Radial Force for the Deep Groove Ball Bearings)

  • 이재선;한동철
    • Tribology and Lubricants
    • /
    • 제14권3호
    • /
    • pp.94-99
    • /
    • 1998
  • Generally not only the radial load but also the moment may be applied to the ball bearings for a shaft system. However it has been difficult to determine the static equivalent load because there is the radial static equivalent equation only for the axial and radial force on the bearings. In this paper, the same static equivalent radial load which makes the maximum contact force at the interface between the ball and groove as the applied radial force and moment generate is calculated under the condition that the radial force and the moment are applied to the bearings simultaneously. The relation between the static equivalent load and applied force is studied. Therefore the simple and effective equation for the static equivalent radial load of the radial load and moment is proposed for the deep groove ball bearings.

임계 CTOA조건을 이용한 파괴해석 (Fracture Analysis Based on the Critical-CTOA Criterion)

  • 구인회
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2223-2233
    • /
    • 1993
  • An engineering method is suggested to calculate the applied load versus crack extension in the elastic-plastic fracture. The condition for an increment of crack extension is set by a critical increment of crack-up opening displacement(CTOD). The ratio of the CTOD increment to the incremental crack extention is a critical crack-tip opening angle(CTOA), assumed to be constant for a material of a given thickness. The Dugdale model of crack-tip deformation in an infinite plate is applied to the method, and a complete solution for crack extension and crack instability is obtained. For finite-size specimens of arbitrary geometry in general yielding, an approximate generalization of the Dugdale model is suggested so that the approximation approaches the small-scale yielding solution in a low applied load and the finite-element solution in a large applied load. Maximum load is calculated so that an applied load attains either a limit load on an unbroken ligament or a peak load during crack extension. The proposed method was applied to three-point bend specimens of a carbon steel SM45C in various sizes. Reasonable agreements are found between calculated maximum loads and experimental failure loads. Therefore, the method can be a viable alternative to the J-R curve approach in the elastic-plastic fracture analysis.

극한상태의 정재하시험결과를 이용한 타입말뚝의 안전율 적용성 평가 (An Applicative Estimation of Safety Factors about Driven Pile Using the Results of Static Loading Test on the Ultimate State)

  • 기완서;박노환;김선학
    • 지질공학
    • /
    • 제19권4호
    • /
    • pp.441-457
    • /
    • 2009
  • 본 연구는 국내 외의 사질지반에 시공된 타입말뚝에 대해 파괴가 현저하게 나타날 때까지 재하한 정재하시험 실측값을 이용하여 극한하중 항복하중 침하량기준의 각각 판정법으로 극한하중을 추정하였다. 추정된 극한하중을 실측된 파괴하중으로 정규화하고 말뚝특성에 따라 판정법별 비교 분석 하였다. 또한 극한하중 추정시 적합한 판정법을 검토하고 허용하중 결정시 안전율을 재평가하여 다음과 같은 결론을 얻었다. 극한하중 판정법으로 구한 극한하중은 Chin 방법에 의해 해석된 값이 실측값 보다 과대평가하는 경향을 나타냈으며 B. Hansen 80%기준과 Stability Plot 방법이 실측치와 거의 일치하여 가장 신뢰성이 있는 방법으로 판단되었다. 허용하중 산정시 극한하중 판정법에 의해 구한 파괴하중에 적용해야 할 안전율을 구조물기초설계기준에 적용된 안전율을 기준으로 환산하면 B. Hansen 90% 방법을 제외하고 3.0보다 큰 값이 적용되어야 할 것으로 판단되었으며 항복하중 판정법들의 경우 기준안전율 2.0보다 큰 값이 적용되어야 할 것으로 판단되었다. 침하량 기준에 의해 구한 하중에 적용해야 할 안전율을 극한하중에 대한 안전율 3.0을 기준으로 환산해 보면, 전침하량 기준 및 순침하량 기준은 3.0보다 작은 값이 적용되어야 할 것으로 판단되었다.

용사법에 의해 제조된 Al/SiC 복합재료의 마모거동 (2) - 작용하중의 영향 - (Wear Behavior of Al/SiC Composites Fabricated by Thermal Spray Process (2) - Effect of Applied Load on Wear Behavior -)

  • 이광진;김균택;김영식
    • Tribology and Lubricants
    • /
    • 제29권5호
    • /
    • pp.298-303
    • /
    • 2013
  • In this work, the effect of applied load on the wear behavior of Al/SiC composites was studied. Al/SiC composites were fabricated following the thermal spray process. Dry sliding wear tests were performed on these composites under four different applied loads, i.e., 5, 10, 15, and 20 N. The wear behaviors of the composites under these applied loads were investigated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Under applied loads of up to 15 N, the wear rates of Al/SiC composites decreased with an increase in the applied load because of the formation of an adhesion layer on the worn surface. However in the case of an applied load of 20 N, the wear rate was significantly high because the formation and fracture of the adhesion layer were repeated continuously. These results show that the wear behaviors of the tested composites are significantly influenced owing to the applied loads.

STS316 용사코팅의 마모거동에 미치는 작용하중 및 미끄럼속도의 영향 (Effect of Applied Load and Sliding Speed on Wear Behavior of Thermally Sprayed STS316 Coating)

  • 이재홍;김영식
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.74-79
    • /
    • 2014
  • This article aims at investigating the effect of applied load and sliding speed on wear behavior of thermally spraryed STS316 coating. STS316 coatings were fabricated by flame spray process according to optimal parameters on steel substrates. Dry sliding wear tests were performed on STS316 coating using four different applied load as 10, 15, 20 and 25 N and four different sliding speed as 15, 30, 45 and 60 rpm. Wear behavior on worn surface was investigated using scanning electron microscope(SEM) and energy disperive X-ray spectroscopy(EDS). The dominant wear mechanism of STS316 coating under low applied load and sliding speed was oxidation on worn surface. However, under high applied load and sliding speed the principal wear mechanism was abrasion on oxidation film and damage of oxidation film.

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

한발서기 동안 동측, 반대측 방향의 상지부하가 다리근육의 근활성도에 미치는 영향 (Effects of ipsilateral and contralateral loading on lower extremity muscle activity during one leg standing)

  • 허재석;이상열
    • 대한물리치료과학회지
    • /
    • 제27권1호
    • /
    • pp.34-42
    • /
    • 2020
  • Background: The purpose of this study was to investigate the effects of ipsilateral and contralateral load changes during single-leg standing on the leg muscle activities of healthy people. Design: Randomized controlled trial. Methods: For all the subjects, a load was randomly applied to the ipsilateral or the contralateral side. While the load was applied, the subject raised a hand and then performed single-leg standing for 10 seconds using the dominant side. Results: During single-leg standing, the muscle activity of the gluteus medius, peroneus longus on the supporting side increased statistically significantly when an upper limb load was applied contralaterally, but no statistically significant differences were detected in the muscle activities of the tibialis anterior and the gastrocnemius using a test of within-subjects effects. Conclusion: It can be seen that muscle activities increase during exercise when the amount and frequency of a load are increased and when the same load is applied to different sides of the body. Such muscle activity increases may be applied to change the intensity of exercise when one is in a static posture, such as during single-leg standing.

원격제어 에어컨 개발 보급현황 및 향후전망 (A development of direct load control system for air-conditioner)

  • 강원구;김충환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

직접 구동형 서보밸브와 전진 보상기를 적용한 유압식 토크 부하 시뮬레이터의 설계에 관한 연구 (The Study of the Design of a Hydraulic Torque Load Simulator Equipped with a Direct Drive Servo Valve and a Feed forward Compensator)

  • 이성래
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.16-27
    • /
    • 2018
  • Hydraulic torque load simulator is essential to test and qualify the performance of various angle control systems. Typically a flapper-type second stage servovalve is applied to the load simulator, but here the direct drive servovalve, which is a kind of one-stage valve and affected by the large flow force, is applied. Since the torque load is applied not to the stationary shaft but to the rotating shaft of the angle control system, the controlled torque of load simulator is not accurate due to the rotating speed of the angle control system. A feedforward compensator is designed and applied to minimize the disturbance-like effect. A mathematical model is derived and linearized to analyze the stability, accuracy and responsiveness of the torque load simulator. The parameter effects of a controller, servovalve, hydraulic motor, rotating spring shaft are analyzed and summarized. The goodness of the linear analysis is verified by the digital computer simulations using both the linear and nonlinear mathematical models.

Finite Element Stress Analysis according to Apical-coronal Implant Position

  • Kang, Tae-Ho;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권1호
    • /
    • pp.52-59
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the influence of apical-coronal implant position on the stress distribution after occlusal and oblique loading. Materials and Methods: The cortical and cancellous bone was assumed to be isotropic, homogeneous, and linearly elastic. The implant was apposed to cortical bone in the crestal region and to cancellous bone for the remainder of the implant-bone interface. The cancellous core was surrounded by 2-mm-thick cortical bone. An axial load of 200 N was assumed and a 200-N oblique load was applied at a buccal inclination of 30 degrees to the center of the pontic and buccal cusps. The 3-D geometry modeled in Iron CAD was interfaced with ANSYS. Results: When only the stress in the bone was compared, the minimal principal stress at load Points A and B, with a axial load applied at 90 degrees or an oblique load applied at 30 degrees, for model 5. The von Mises stress in the screw of model 5 was minimal at Points A and B, for 90- and 30-degree loads. When the von Mises stress of the abutment screw was compared at Points A and B, and a 30-degree oblique load, the maximum principal stress was seen with model 2, while the minimum principal stress was with model 5. In the case of implant, the model that received maximum von Mises stress was model 1 with the load Point A and Point B, axial load applied in 90-degree, and oblique load applied in 30-degree. Discussion and Conclusions: These results suggests that implantation should be done at the supracrestal level only when necessary, since it results in higher stress than when implantation is done at or below the alveolar bone level. Within the limited this study, we recommend the use of supracrestal apical-coronal positioning in the case of clinical indications.