• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.037 seconds

Calculation of depth dose for irregularly shaped electron fields (부정형 전자선 조사면의 심부선량과 출력비의 계산)

  • Lee, Byoung-Koo;Lee, Sang-Rok;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • The main cause factor for effective the output, especially in small & irregular shaped field of electron beam therapy, are collimation system, insert block diameter and energy. In the absorption deose of treatment fields, we should consider the lateral build-up ratio (LBR), which the ratio of dose at a point at depth for a given circular field to the dose at the same point for a 'broad-field', for the same incident fluence and profile. The LBR data for a small circular field are used to extract radial spread of the pencil beam, ${\sigma}$, as a function of depth and energy. It's based on elementary pencil beam. We consider availability of the factor, ${\sigma}$, in the small & irregular fields electron beam treatment.

  • PDF

Design optimization and fabrication of a magnetic roll in coater for reducing coat resin deviation (수지부착량 편차저감을 위한 수지 coater용 magnetic roll의 설계 및 제작)

  • 박언병;김상원
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.122-123
    • /
    • 2002
  • 현재 제철소 냉연공장에서는 수지처리 강판을 생산하기 위하여 수지 coater를 사용하고 있다. 그런데 강판의 이면 피복 시, applicator roll에 대한 back-up roll의 균일 하중 부하로 수지의 균일한 피복이 실현되나, 전면을 피복할 때 하중 부하를 위한 별도의 tool이 없는 상태로 강판의 hunting에 대응 불가능한 현장 layout으로 되어 전면 수지부착량 편차가 크게 발생되었다. (중략)

  • PDF

Properties of Acrylic Pressure Sensitive Adhesive Performance and Evaluation Using Combinatorial Methods (조합기법을 활용한 아크릴 점착제의 점착물성 평가)

  • Park, Ji Won;Lim, Dong-Hyuk;Kim, Hyun Joong;Kim, Kyoung Mahn;Kim, Hyung Il;Ryu, Jong Min
    • Journal of Adhesion and Interface
    • /
    • v.10 no.3
    • /
    • pp.127-133
    • /
    • 2009
  • Acrylic pressure sensitive adhesives (PSAs) are used in various field of high-technology industries such as semiconductor, display, mobile, automobile, and so on. Because of they have high durabilities and can be easily introduced functional groups in their molecular structures. PSA perfomances has an effect on their applications in industry process operation, reliability of final products. In this study, PSA performances as a function of fim thickness which is one of the impact factors effects on PSA performances will be investigated using combinatorial methods. Acrylic PSAs are synthesized using 2-ethylhexyl acrylate and acrylic acid. Thickness-gradient of acrylic PSA sample is made by a micro applicator. We compare general coating method with thickness-gradient coating method and evaluate the reappearance of combinatorial methods compared with existing coating method. Thickness-gradient of acrylic PSA sample shows rough and broad data tendency.

  • PDF

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

Risk Assessment of Baby Powder Exposure through Inhalation

  • Moon, Min-Chaul;Park, Jung-Duck;Choi, Byung-Soon;Park, So-Young;Kim, Dong-Won;Chung, Yong-Hyun;Hisanaga, Naomi;Yu, Il-Je
    • Toxicological Research
    • /
    • v.27 no.3
    • /
    • pp.137-141
    • /
    • 2011
  • This study was conducted to assess the exposure risk through inhalation to baby powder for babies and adults under simulated conditions. Baby powder was applied to a baby doll and the amount of baby powder consumed per application was estimated. The airborne exposure to baby powder during application was then evaluated by sampling the airborne baby powder near the breathing zones of both the baby doll and the person applying the powder (the applicator). The average amount of baby powder consumed was 100 mg/application, and the average exposure concentration of airborne baby powder for the applicator and baby doll was 0.00527 mg/$m^3$ (range 0.00157~0.01579 mg/$m^3$) and 0.02207 mg/$m^3$ (range 0.00780~0.04173 mg/$m^3$), respectively. When compared with the Occupational Exposure Limit of 2 mg/$m^3$ set by the Korean Ministry of Labor and the Threshold Limit Value (TLV) of 2 mg/$m^3$ set by the ACGIH (American Conference of Governmental Industrial Hygienists), the exposure concentrations were much lower. Next, the exposure to asbestos-containing baby powder was estimated and the exposure risk was assessed based on the lung asbestos contents in normal humans. As a result, the estimated lung asbestos content resulting from exposure to asbestos-containing baby powder was found to be much lower than that of a normal Korean with no asbestos-related occupational history.

Adhesion Properties of Hot-Melt Pressure Sensitive Adhesives Based on Metallocene Polyolefin (메탈로센 폴리올레핀을 이용한 핫멜트 점착제의 제조 및 특성)

  • Shim, Jaeho;Sung, Ickkyeung;Lee, Jungjoon
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.95-100
    • /
    • 2013
  • In this study, a series of hot-melt pressure sensitive adhesives (HMPSAs) based on metallocene polyolefin (me-PO) were prepared to investigate their possibility of replacing the HMPSAs based on styrenic block copolymers (SBCs). In addition, to optimize the performance of HMPSAs based on me-PO, several tackifiers having different softening point and molecular weight were evaluated. To achieve the HMPSAs which can satisfy the Dahlquist Criterion, hot melts required over 10% of process oil. To obtain the HMPSAs having low viscosity which can be applied by a spraying type applicator, secondary polymer having relatively low crystallinity was required. And, tackifier having high molecular weight attributed to increasing the cohesive strength of me-PO based HMPSAs.

Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer (자궁경부암의 고선량율 강내치료 선량계획 분석)

  • Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF

A Study on the Effect of Field Shaping on Dose Distribution of Electron Beams (전자선의 선량분포에 있어서 Field Shaping의 효과에 관한 연구)

  • Kang, Wee-Saing;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.165-172
    • /
    • 1986
  • In electron therapy, lead cutout or low-melting alloy block is used for shaping the field. Material for shaping electron field affects the output factor as wet 1 as the collimation system. The authors measured the output factors of electron beams for shaped fields from Clinac-18 using ionization chamber of Farmer type in polystyrene phantom. They analyzed the parameters that affect the output factors. The output factors of electron beams depend on the incident energy, collimation system and size of shaped field. For shaped field the variation of output factor for the field size (A/P) has appearence of a smooth curve for all energy and all applicator collimator combination. The output factors for open field deviate from the curves for shaped fields. An output factor for a given field can be calculated by equivalent field method such as A/P method, if a combination of applicator and collimator is fixed.

  • PDF

Dynamics and Instability of a Polymeric Paint in Roll Coating Process for Automotive Pre-coating Application (자동차 선도장을 위한 롤코팅 공정에서 고분자 도료의 동적 거동 및 불안정성)

  • Kim, Jin-Ho;Lee, In-Jun;Noh, Seung-Man;Kang, Choong-Yeol;Nam, Joon-Hyun;Jung, Hyun-Wook;Park, Jong-Myung
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.574-579
    • /
    • 2011
  • 3-Roll coating process as a key application technology for manufacturing automotive pre-painted metal-sheets has been studied. The 3-Roll coating system for this study consists of pick-up roll for picking up and distributing coating liquid from the reservoir, metering roll to properly meter coating liquid in metering gap regime, and applicator roll for directly transferring liquid into metal-sheet surface. Flow dynamics and operable coating windows of a polymeric paint (primer) with shear-thinning rheological property have been correlated with processing parameters such as speed ratio and metering gap between pick-up and metering rolls. In the uniform coating regime, dry coating thickness increased with increasing metering gap or decreasing speed ratio. Ribbing and cascade instabilities were observed in low speed and high speed ratio conditions, respectively. It is revealed that lower speed ratio makes severity and wavelength of the ribbing increase, aggravating flow instability in coating systems.

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF