• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.023 seconds

Radiotherapy Result of the Carcinoma of Uterine Cervix (자궁경부암의 방사선치료성적)

  • Park, Charn-Il;Ha, Sung-Whan;Kang, Soon-Beom;Lee, Hyo-Pyo;Shin, Myon-Woo
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.107-113
    • /
    • 1984
  • One hundred sixty one patients with the carcinoma of uterine cervix received curative radiotherapy at the Department of Therapeutic Radiology, Seoul National University Hospital between December, 1979 and December, 1982. According to FIGO classification; stage $I_a 1(0.6\%)\;1_b\;8(5.0\%),\;II_a\;31(19.3\%),\;II_b\;66(41.0\%),\;III_a\;3(1.8\;%),\;III_b\;46(28.6\%)\;and\;IV_a\;6(3.7\;%)$. The proportion of early stage cancer is too small because most of them treated by surgery. External beam whole pelvic irradiation was done first with 10MV x-ray or Co-60 gamma ray upto 4,000 or 5,000 rad for early and advanced cases, followed by one or two courses of intracavitary radiation using Fletcher-Suit Applicator loading c Cs-137. Supplementary external radiation to pelvic side wall to bring dose to 6,000 or 6,500 rads, if there is parametrial involvement or positive pelvic lymph node. Of the 161 Patients, 49 Patients were lost to follow-up but only 22 patients were lost in disease free state. And so, 86.3 percent of the patients were followed to time of recurrence or to date. The results are as follows ; 1. Locoregional control rates according to stage is: stage I $100\%,\;II_a\;90.3\;%,\;II_b\;75.8\%,\;III_a\;66.7\%,\;III_b\;58.7\%\;and\;IV_a\;16.7\%$, respectively. 2. Persistent or recurrent disease were localized in pelvic cavity in 32 of 50 patients and 6 had distant metastasis only. 3. Rectal bleeding was the most common complication and appeared mostly between 6 and 24 months after radiotherapy. Most of them had transient minor bleeding and only 2 patients needed transfusion and 1 patient needed colostomy due to rectovaginal fistula. 4. The 3 year disease free survival rate is: stage I $100\%,\;II_a\;78.0\%,\;II_b\;60.6\%,\;III_a\;66.7\;III_b\;46.3\%\;and\;IN_a\;16.7\%$, respectively.

  • PDF

Effect of Band Spotty Fertilization for Reduction of Nitrogen Fertilizer on Chinese Cabbage(Brassia campestris L.) in Plastic Film Mulching Cultivation (비닐피복 배추 재배시 국소시비에 의한 질소질비료의 절감 효과)

  • Yang, Chang-Hyu;Ryu, Chul-Hyun;Shin, Bok-Woo;Kang, Seung-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • This study was conducted to establish a low-input fertilization technique and increase of fertilization efficiency using the band spotty applicator(1999-2000) during the cultivation of mulching for chinese cabbage(Brassia campestris L.). The obtained results such as nitrogen efficiency, yield and soil improvement after cultivation of chinese cabbage were as follows. The content of $NO_3-N$ in soil increased in band spotty fertilization(BSF) by increasing application rate from the beginning stage to the middle stage. The content of total nitrogen increased but content of organic matter, available phosphate and exchangeable potassium decreased in comparison with the soil before experiment. Growth rate of Chinese cabbage increased in band spotty fertilization plot and uptake amount of nitrogen fertilized for chinese cabbage increased by increasing of the application rate. N use efficiency was higher by 5-21% in band spotty fertilization plot than in conventional fertilization(CF) plot. Yield of chinese cabbage increased by 16% in 70% band spotty fertilization plot and increased by 20% in 100% band spotty fertilization plot. It was found that 70% band spotty fertilization was more effective as fertilization method to reduce both environmental pollution and chemical nitrogen fertilizer in plastic film mulching cultivation.

Fabrication and characterization of 3-D porous scaffold by polycaprolactone (폴리카프로락톤을 이용한 3차원 다공성 지지체 제조 및 특성 분석)

  • Kim, Jin-Tae;Bang, Jung Wan;Hyun, Chang-Yong;Choi, Hyo Jeong;Kim, Tae-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.58-65
    • /
    • 2016
  • This study was a preparatory experiment aimed the development of membrane scaffolds for tissue engineering. A PCL composite solution contained sodium chloride(NaCl). PCL porous membrane scaffolds were formed on a glass casting plate using a film applicator and immersed in distilled water to remove the NaCl reaching after drying. NaCl was used as a pore former for a 3 dimensional pore net-work. The dry condition parameters were $4^{\circ}C$, room temperature (RT) and $40^{\circ}C$ for each different temperatures in the drying experiment. SEM revealed the morphology of the pores in the membrane after drying and evaluated the in vitro cytotoxicity for basic bio-compatibility. The macro and micro pores existed together in the scaffold and showed a 3-dimensional pore net-working morphology at RT. The in vitro cytotoxicity test result was "grade 2" in accordance with the criterion for cytotoxicity by ISO 10993-5. The dry condition affected the formation of a 3 dimensional pore network and micro and macro pores. Therefore, these results are expected provide the basic process for the development of porous membrane scaffolds to control degradation and allow drug delivery.

The Dose Characteristics of Designed Ir-192 Micro-source for Brachytherapy (근접조사용 Ir-192 마이크로선원의 디자인과 선량 특성)

  • 최태진;김진희
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.81-89
    • /
    • 2003
  • The dose distributions of designed Ir-192 micro-source were investigated by dose computations which were accomplished by employing shape of encapsule material and thickness of the source for self-absorption. The computation dose derived from air-kerma rate (S$_{k}$ ) and dose rate constant (Λ) includes the anisotropy of dose distribution around the source. We got the dose rate constants in a water medium is 1.154 cGy h$^{-1}$ U$^{-1}$ . The size of the source was 0.5 mm in diameter and 3.5 mm in length and it was encapsuled in 1.1 mm$\Phi$${\times}$5.5 mm of stainless steel sealed with 0.3 mm of filter thickness. The tissue dose of reference point at 1.0 cm radial distance of the source axis was delivered 1.154 Uh$^{-1}$ (1.3167${\times}$10$^{-3}$ cGy/mCi-sec) from the S$_{k}$ 4.108U/mCi of Ir-192 source. The filtration effect contributed to air-kerma strength as exponential filtering effect of 86.2% in total attenuation, but self-absorption was 88.4% from radial dose distributions. In particular, the dose attenuations showed a rapid anisotropic distributions as 56% of reference dose along to $\pm$10 degrees from the tip of source axis and 50% for of that to source-cable direction. We persist in use the large diameter of applicator will avoid the dose anisotropy by the filtered attenuation effects along the axis of Ir-192 micro-source.

  • PDF

A Study on the Wearing Condition and Satisfaction of Pesticide Protective Clothing (농약방제복 착용실태 및 만족도에 관한 연구)

  • Oh, Young-Soon;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Kyung-Ran;Kim, Sung-Woo
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.4
    • /
    • pp.217-228
    • /
    • 2014
  • The purpose of this study is to grasp inconveniences and improvements by examining wearing condition and satisfaction of protective clothing targeting 114 Korean farmers and to suggest basic data for enhancement of pattern and wearing satisfaction of protective clothing by understanding problems of pesticide-proof clothing through comparative analysis on the size of its commercial products. Most of male subjects were in charge of spraying pesticide, whereas female were most likely to play an assistant role to hold the hose of pesticide applicator. Both of female and male subjects were very aware of the harmful effect of pesticide on human body and tried to take off the clothes immediately after spraying it to reduce possible damage caused by pesticide. As a result of examining wearing condition, the farmers avoided wearing protective clothing because that it feels hot, stuffy, and uncomfortable to move. This hesitant response of wearing the clothing was not shown significantly in case of female subjects who play an assistant role for spraying. Although the farmers wore protective equipments such as mask or gloves in a proper way as compared to protective clothing, they seemed to choose alternative way rather than best way to block pesticide completely. The satisfaction regarding to the fitting of protective clothing which the subjects showed low in all items of upper-lower clothes except waistline. It is necessary to improve the functionality such as relief from heat stress and convenience for movement rather than design or economic in protective clothing development. As a result of comparing the size of five kinds of commercial protective clothing, the farmers got confused to choose the product since designation method of size across companies showed a significant difference in an identical clothing size. In addition, the sizing system developed on a basis of a well-built man has become a hindering factor in wearing satisfaction of female farmers.

  • PDF

Effect of Band Spotty Fertilization on the Yield and Growth of Peanut(Arachis hypogaea L.) in Plastic Film Mulching Cultivation (비닐피복 땅콩 재배시 생육 및 수량에 미치는 국소시비 효과)

  • Yang, Chang-Hyu;Yoo, Chul-Hyun;Shin, Bok-woo;Cheong, Young-Keun;Kang, Seung-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.298-302
    • /
    • 2006
  • This study was carried out to establish low-input fertilization and seeding technique using the simultaneous with seeding and fertilizer application machine and band spotty applicator which were manufactured for experiment during cultivation of mulching for peanut(Arachis hypogaea L.). The labor hour for seeding by simultaneous with seeding and fertilizing machine was appeared over 90% reduction effect compared with control plot($17.3hr\;10a^{-1}$). In band spotty fertilization plots, the emergence date was delayed about 4 days and the seedling stand rate was decreased 11~18% compared with control plot(man power). The content of total nitrogen of soil after experiment was increased while the contents of organic matter, available phosphate and exchangeable potassium were decreased than before experiment. The content of nitrogen forming nitrate was increased in band spotty fertilization(BSF) plots by increasing the amount of applied fertilizer from early growth stage till the middle growth stage. Growth rate was increased in band spotty fertilization plots and the absorbed amount of phosphate and potassium for peanut were increased in 70% band spotty fertilization plot compared with control plot. Yield of peanut was increased 70% in band spotty fertilization plot due to high pod kernel ratio and ripened pod rate compared with control plot($3,150kg\;ha^{-1}$). It was found that 70% band spotty fertilization was more effective as fertilization method to reduce both environmental pollution and chemical nitrogen fertilizer in plastic film mulching cultivation of peanut.

An Experimental Study on the Effect of Combined X-ray and Microwave Hyperthermia on the Rectum and Urinary Bladder of Rats (흰쥐의 직장과 방광에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.115-128
    • /
    • 1986
  • Hyperthermia can enhance the radiation effect as a synergistic reaction in combined X-ray irradiation and hyperthermia; hyperthermia sensitize radioresistant S-phase cells and inhibit cellular recovery from sublethal damage. We fabricated 100 watts, 2450 MHz microwave applicator for hyperthermia and planned the method and condition of heating and measured the temperature by using Agar phantom as a preliminary test. For biological examination, 102 rats were divided into 4 groups as hyperthermia, X-ray irradiation (6Gy-15Gy), combined X-ray and hyperthermia, and normal control groups. Microscopic examination of the rectum and bladder was done and the results were as followings: 1. The microwave generator with 100 watts, 2450MHz magnetron could be heating up to $40^{\circ}{\sim}50^{\circ}C$ for one hour in living tissue. 2. The thermal distribution in tissue equivalent phantom with microwave can be maintained at $40^{\circ}{\sim}44^{\circ}C$ in area of 3cm in depth and 2-10cm in diameter. 3. In Hyperthermia alone group, there was submucosal edema of the rectum but no histologic change in the urinary bladder was seen. 4. The minimal necrosis of the mucosa was appeared in the rectum and bladder after 15 days of 6 Gy and 8 Gy irradiation respectively. The minimal necrosis of the muscle layer of rectum and bladder was appeared after 15 days of 8Gy and 60days of 10Gy irradiation respectively. 5. In combined group of radiation and hyperthermia, thermal enhancement ratio (calculated at necrosis of mucosa and muscle layer) of rectum and bladder was 1.0, and it suggest that there is no change of tolerance dose of normal rectum and bladder.

  • PDF

Intraoperative Radiotherapy (IORT) for Locally Advanced Colorectal Cancer (대장-직장암의 수술중 방사선 치료)

  • Kim, Myung-Se;Kim, Sung-Kyu;Kim, Jae-Hwang;Kwan, Koing-Bo;Kim, Heung-Dae
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.265-270
    • /
    • 1991
  • Colorectal cancer is the second most frequent malignant tumor in the United States and fourth most frequent tumor in Korea. Surgery has been used as a primary treatment modality but reported overall survivals after curative resection were from $20\%\;to\;50\%$. Local recurrence is the most common failure in the treatment of locally advanced colorectal cancer. Once recurrence has developed, surgery has rarely the role and the five year survival of locally advanced rectal cancer is less than $5\%$, in spite of massive combination therapy. Intraoperative radiotherapy (IORT) with or without external beam irradiation has been advocated for reducing local recurrence and improving survival. The recent report of local failure by this modality was only $5\%$, this indicated that significant improvement of local control could be achieved. We performed 6 cases of IORT for locally advanced colorectal cancer which is the first experience in Korea. Patient's eligibility, treatment applicator, electron energy, dose distribution on the surface and depth within the treatment field and detailed skills are discussed. We hope that our IORT protocol can reduce local failure and increase the long term survival significantly.

  • PDF

Herbicidal Effects on the Differential Rice Cultivation Condition and Damage of No-target Plants of Macro Granule Herbicide for Remote-controlled Aerial Application (무인헬기용 Macro granule 제초제의 벼 작형별 살초효과 및 주변작물에 미치는 영향)

  • Yoon, Cheol-Su;Bae, Chang-Hyu;Lee, Sheong-Chun;Kim, Kyung-Hyun;Lee, Kye-Hwan;Cho, Tae-Kyoung;Hwang, In-Cheon
    • Korean Journal of Weed Science
    • /
    • v.31 no.4
    • /
    • pp.375-383
    • /
    • 2011
  • This experiment was carried out to confirm characteristics of macro granule (GG) for herbicidal efficacy by using remote-controlled aerial application (RCAA) to control annual and perennial weeds in rice paddy field, and phytotoxicity to rice and non target plants of formulation types. Herbicidal efficacy of GG applied by using RCAA was 93.6~96.6% in flooded direct sowing cultivation. There was no difference in phytotoxicity between the hand and the power applicator methods in terms of height, number of tiller and yield component. Herbicidal efficacy of GG applied by using RCAA was 92.7~97.3% in machine transplanting rice field. There was no difference in phytotoxicity between the hand and RCAA methods in terms of height, number of tiller and yield component. When suspension concentrate (SC) and GG were applied directly on Chinese cabbage, lettuce, cucumber, pepper, soybean and wild sesame, several symptoms of injury such as, the inhibition of growth, yellowish, leaf fall and withering was observed.

Verification of Balloon Catheter for Rectal Dose Reduction in Brachytherapy (강내 방사선치료에 있어 직장선량 감소를 위한 풍선형 카테터의 검증)

  • To-Sol, Yu;Young-Min, Moon;Wan, Jeon;Chul-Won, Choi;Bae, Sang-Il;Jin-Young, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.735-740
    • /
    • 2022
  • In order to reduce side effects such as rectal bleeding in the Brachytherapy, the rectal retractor and wet gauze have been used to increase the distance between the rectum and the tandem. However, there were disadvantages that it was difficult to insert through a narrow entrance into the vagina and poor reproducibility. Also, based on the CT image of the selected catheter, the distance from the tandem to the rectum with or without the balloon catheter was checked and the reduction of the dose to the rectum was confirmed. As a result of the experiment, catheter No. 7 was selected considering the maximum balloon size at a level that does not affect the distance between the start point of the balloon and the end of the catheter, and the ovoid applicator. Based on the CT image of the selected catheter, the degree of expansion according to the presence or absence of the balloon catheter was compared, and it was found that the distance difference was 0.3 - 1 cm. In addition, it was confirmed that a decrease of about 32% was observed due to this distance difference. Therefore, the actual clinical application of the selected catheter can be used as a substitute for the existing rectal retractor and wet gauze.