• 제목/요약/키워드: application window

검색결과 488건 처리시간 0.026초

Fabrication and Characterization of the BLT/STA/Si Structure for Fe-FETs Application

  • Park, Kwang-Huna;Jeon, Ho-Seung;Park, Jun-Seo;Im, Jong-Hyun;Park, Byung-Eun;Kim, Chul-Ju
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.73-74
    • /
    • 2006
  • Ferroelectric thin films have been widely investigated for future nonvolatile memory application. We fabricated the BLT ($(Bi,La)_4Ti_3O_{12}$) films on Si using a STA ($SrTa_2O_6$) buffer layer BLT and STA film were prepared by sol-gel method. Measurement data by XRD and AFM, showed that BLT film and STA films were well crystallized and a good surface morphology. From C-V measurement reward that the Au/BLT/STA/Si structure showed a clockwise hysteresis loop with a memory window of 1.5 V for the bias voltage sweep of ${\pm}5$ V. From results, the Au/BLT/STA/Si structure is useful for FeFETs.

  • PDF

생물의료용 연 X-선 현미경 시스템 개발 (Development of a soft X-ray microscopy system for Biological Application)

  • 김경우;권영만;김규겸;민종환;박정권;임종혁;남기용;윤권하;민진영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2005년도 제16회 정기총회 및 동계학술발표회
    • /
    • pp.264-265
    • /
    • 2005
  • In this paper the conceptual design and development of a compact vertical type soft x-ray microscope is described. This x-ray microscope operates in the water window wavelength region(2.3 ${\sim}$ 4.4nm), where natural contrast between carbon(protein) and oxygen(water) allows imaging of unstained biological material their natural, hydrated environment. Until now, operational x-ray microscopes are based on synchrotron radiation sources, which limit their accessibility. Many biologists would benefit from having the x-ray microscope as a tool among other tools in their own laboratory, For this purpose we introduced the compact vertical type soft X-ray microscope with 50 nm resolution for biomedical application. The compact vertical type soft x-ray microscope is based on a laser plasma x-ray source, doubled ellipsoidal condenser reflective optics, diffractive zone plate optics and MCP coupled with CCD to record an x-ray image.

  • PDF

MPMTP-AR: Multipath Message Transport Protocol Based on Application-Level Relay

  • Liu, Shaowei;Lei, Weimin;Zhang, Wei;Song, Xiaoshi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권3호
    • /
    • pp.1406-1424
    • /
    • 2017
  • Recent advancements in network infrastructures provide increased opportunities to support data delivery over multiple paths. Compared with multi-homing scenario, overlay network is regarded as an effective way to construct multiple paths between end devices without any change on the underlying network. Exploiting multipath characteristics has been explored for TCP with multi-homing device, but the corresponding exploration with overlay network has not been studied in detail yet. Motivated by improving quality of experience (QoE) for reliable data delivery, we propose a multipath message transport protocol based on application level relay (MPMTP-AR). MPMTP-AR proposes mechanisms and algorithms to support basic operations of multipath transmission. Dynamic feedback provides a foundation to distribute reasonable load to each path. Common source decrease (CSD) takes the load weight of the path with congestion into consideration to adjust congestion window. MPMTP-AR uses two-level sending buffer to ensure independence between paths and utilizes two-level receiving buffer to improve queuing performance. Finally, the MPMTP-AR is implemented on the Linux platform and evaluated by comprehensive experiments.

레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계 (Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application)

  • 김경우;윤권하
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구 (Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM))

  • 송영학;김기태;구보경;이건호
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

3-5 $\mu m$ 적외선 흡수체를 가진 전면 건식 식각된 서모파일과 NDIR $CO_2$ 가스 센서의 응용 (A Front-side Dry-Etched Thermopile Detector with 3-5 $\mu m$ Infrared Absorber and Its Application to Novel NDIR $CO_2$ Gas Sensors)

  • 유금표;김시동;최우석;;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1470-1471
    • /
    • 2008
  • We present a front-side micromachined thermopile with high sensitivity in the 3-5${\mu}m$ window, and discuss its application to a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. The micromachined thermopile shows a measured sensitivity of 30 mV/W and a $D^*$ of $0.3{\times}10^8cm^{\surd}Hz/W$. Using this newly fabricated thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

컴퓨터 그래픽 표준에 대한 조사연구 (A Survey of the Computer Graphics Standards)

  • 한순흥;서승완
    • 대한조선학회논문집
    • /
    • 제29권2호
    • /
    • pp.18-29
    • /
    • 1992
  • 컴퓨터 그래픽의 사용이 보편화 되어감에 따라 컴퓨터 그래픽에 대한 표준화가 필요하게 되었다. 국가적인 차원의 공용(共用) 시스템을 개발하려는 CSDP 사업을 위해서도 공통적으로 쓰일 그래픽 라이브러리의 선정이 필요하다. 이 글에서는 여러가지 그래픽 표준들에 대해 조사 및 정리하고, 전체적인 관점에서 그들의 상관관계를 살펴보았으며, 우리가 추진해 나가야할 방향에 대하여 검토해 보았다. 따라서 ISO 같은 국제적인 공공기관에서 채택된 표준들도 중요하지만, 산업계에서 널리 사용되므로서 표준이나 마찬가지인 그래픽 라이브러리들도 중요하다. De facto standard라고 부르는 이러한 그래픽 라이브러리들을 함께 다루어 보았다.

  • PDF

통계적 접근법에 의한 수압파쇄 자료해석용 전산 프로그램 개발 및 적용 (Developement and application of Statistical Hydrofracturing Data Processing Program)

  • 류동우;최성웅;이희근
    • 터널과지하공간
    • /
    • 제6권3호
    • /
    • pp.209-222
    • /
    • 1996
  • Shut-in pressure, reopenting pressure and fracture orientation are very important parameters to be evaluated precisely in in-situ stress measurement by hydraulic fracturing. Graphical methods on pressure-time curves have been conventionally used, even though these are seriously dependent on subjectivity of interpreters. So there have been many demands on new method to objectivity in determining parameters. We have developed integrated hydrofracturing data processing program (HYDFRAC), based on nonlinear regression analysis and can be invoked under the Window graphical user interface. HYDFRAC consiste of three routines, that is shut-in pressure routine, reopening pressure routine, and fracture delineation routine. Each of routines include independent modules according to parameter determination methods. Its application to field tests ensured both objectivity and facility in determining of hydraulic fracturing parameters. Determining shut-in pressures at each pressurization cycles, we adopted the exponential pressure-decay method(EPD method), the bilinear pressure-decay-rate method (PDR method), and the tangent intersection method in order to find the pressurization-cyclic tendency of shut-in pressures. The estimated pressure by PDR method exists in the range of the upper and lower values by EPD method, and lies near to the upper value more than the lower. Being the pressurization cycle increased, the range of upper and lower limits come to be stabilized gradually. By graphical superposition method and bilinear pressure-accumulated volume method, reopening pressures were determined. Vertical and inclined fracture attitudes were determined by applying the directional statistics and sinusoidal curve fitting, respectively. The results of evaluation of hydrofracturing parameters showed that statistical methods could enhance the objectivity better than graphical methods.

  • PDF

동계에 차양 적용에 의한 실내 환경 측면의 효과에 관한 실험적 연구 (An Experimental Study on the Effect on Indoor Environment by the Application of the Shading Device in Winter)

  • 백주영;김지현;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.854-859
    • /
    • 2006
  • This study aims to evaluate the effect on indoor environment by the application of the shading device on winter season. Therefore, thermal and visual experiments were conducted at two side-by-side mock-Lip test cells which were equipped with the shading device(venetian blind & roll blind) at interior and exterior side of the window. The results of this study are as follows: 1) At night of winter, the shading device can prevent internal heat from going out. 2) Exterior shading device is more effective in winter as well as in summer. 3) At daytime of winter, the shading device can provide the uniformity of illuminance, and the interior shading device is more effective.

  • PDF

Change reaction of fatigue recovery material before and after taping during isokinetic exercise

  • CHOI, Seung-Chul;LEE, Sang-Ho;KIM, Jun-Su
    • 식품보건융합연구
    • /
    • 제7권3호
    • /
    • pp.25-32
    • /
    • 2021
  • This study examined the effects of kinesio taping on recovery from fatigue induced by an exercise of concentric contraction using an isokinetic machine. The fatigue was introduced by a mode of exercise at 60°/sec, 50 repetitions for three sessions. The changes of blood ammonia, lactate, LDH, and CK as a marker of fatigue were monitored. Eight healthy collegiate students participated in two experiments; 1) kinesio taping application condition and 2) no kinesio taping application condition. Before experiments, their physical characteristics were measured. For the experiment, blood samples were taken before and immediately after exercise, and 24hr as well as 72hr of recovery period. Window SPSS package 12.0 version was used and one-way ANOVA with repeated measures were employed. The results were as follows. 1) Blood ammonia tended to reduce along the recovery, but no differences between conditions were noticed. 2) Blood lactate tended to reduce during the recovery period, but differences between conditions were not noticed. 3) The LDH was not different between conditions and CK tended to reduce during the recovery period, but differences between conditions were not noticed. Based on the results, kinesio taping did not influence on recovery phase of blood ammonia, lactate concentration, LDH, and CK.