• Title/Summary/Keyword: application method

Search Result 22,754, Processing Time 0.06 seconds

Skin Improvement Effects and Development of Liposome Capsule Technology Using Centella Asiatica Extract Powder (센텔라아시아티카정량추출물의 리포좀 캡슐기술 개발과 피부개선효과)

  • Kim, Seong Jang;Ju, Yeon Jeong;Kim, In-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1285-1297
    • /
    • 2020
  • In this study, we report the results of a study on the clinical evaluation of wrinkle improvement by developing a method for liposome of high-purity Centella asiatica extract used in pharmaceuticals and cosmetics, and a cream using the same. In order to make Centellasome-10EX stabilizing centella asiatica extract in liposome lamella vesicle, it could be completed using 5% hydrogenated lecithin and 2% sucrose distearate. The appearance of Centellasome-10EX was a creamy form of low viscosity, the color was pale yellow, and the odor had the inherent odor of the raw material. The pH was about 6.12, the specific gravity was 1.09, and the acid value was about 0.35. The content of the main constituents of centella asiatica extract contained in the liposome vesicle contains 10,800 ppm of asiatic acid, 10,900 ppm of asiaticoside, 6,000 ppm of madecasic acid, and 1,600 ppm of madecassoside, and long-term storage. There was no discoloration even at the time, and it was found that the main component remained stable thermodynamically. To mechanistically analyze the structure of the liposome vesicle of Centellasome-10EX, as a result of observation with a transmission electron microscope (Cryo-TEM), the multilayer vesicles are formed and filled with moisture, and there are 10 to 60 multilayers around it. It was confirmed that the liposome lamella vesicle was formed. As a clinical trial (in-vivo) test, the moisturizing effect of centellasome cream after application for 5 weeks was 28.3%, which was significantly increased compared to placebo. The skin elasticity effect was 13.6%, which significantly increased the moisturizing power than the placebo. The effect of improving fine wrinkles around the eyes was improved by 23.52% compared to placebo cream. Through the results of this study, it was possible to study the formulation and manufacturing method for encapsulation and stabilization of the developed Centellasome-10EX in the liposome vesicle. It is expected that the results obtained through clinical research on the wrinkle improvement effect of the cream using this can be widely used to study skin science in the cosmetic industry and to develop high-quality cosmetics with high efficacy.

Tissue Engineered Cartilage Formation on Various PLGA Scaffolds (PLGA 종류와 담체의 형성 방법에 따른 인간의 조직공학적 연골형성)

  • 김유미;임종옥;정호윤;박태인;백운이
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.147-153
    • /
    • 2002
  • The purpose of this study was to evacuate the effect of different types of Poly(lactic-co-glycolic acid) (PLGA) scaffolds on the formation of human auricular and septal cartilages. All of the scaffolds were formed in a tubular shape for potential application for artificial trachea or esophagus with either 110,000 g/mol PLGA. 220,000 g/mol PLGA. or a combination of both. In order to maintain the tubular shape in vivo, two methods were used. One method was inserting polyethylene tube at the center of scaffolds made of 110,000 g/mol PLGA. The other method involved combination of the two different molecular weight PLGA's. The inner surface of tubular shaped scaffold made with 110,000 g/mol PLGA was coated with 220,000 9/mol PLGA to give more mechanical rigidity. Elastic cartilage was taken from the ear of a patient aged under 20 nears old and hyaline cartilage was taken from the nasal septum. The chondrocytes were then isolated. After second passage, the chondrocytes were seeded on the PLGA scaffolds followed by in vitro culture for one week. The cells-PLGA scaffold complex were implanted subcutaneously on the back of nude mice for 8 weeks. The tissue engineered cartilages were separated from nude mice and examined histologically after staining with the Hematoxylin Eosin. The morphology of the scaffolds were examined by scanning electron microscopy. The pores were well formed and uniformly distributed in the various PLGA scaffolds. After 8 weeks in vivo culture, cartilage was well formed with 110,000 g/mol PLGA. however lumen had collapsed. In contrast. a minimal amount of neocartilage was formed with 220,000 g/mol PLGA, while the architecture of scaffold and lumen were well preserved. Elastic cartilage formed more neocartilage than hyaline. Hyaline and elastic neocartilage were well formed on 110,000 g/mol PLGA with the polyethylene tube, exhibiting mature chondrocytes and preservation of the tubular shape. It was found that 110,000 g/mol PLGA was more appropriate for cartilage formation but higher molecular weight polymer was necessary to maintain the three dimensional shape of the scaffold.

The application of alternative methods for skin irritation evaluation on pesticides (농약에 대한 피부자극성 대체시험법 적용연구)

  • Jeong, Mi-Hye;Kim, Mi-Kyoung;Park, Soo-Jin;You, Are-Sun;Hong, Soon-Sung;Park, Kyung-Hun;Park, Jae-Eup
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.261-266
    • /
    • 2012
  • It is common to use many experiment animals to evaluate the toxicity of chemicals including pesticides. For protecting animal, the concepts of 3R (Reduction, Replacement, Refinement) were introduced and in vitro alternatives methods actively have been developed all over the world. Many experimental animals for toxicological tests have been used, so that it is important to establish the alternative methods. In this study, the alternative method using reconstituted human skin model (Keraskin$^{TM}$) was conducted for classification of skin irritation on pesticides. Sixteen formulations selected on the basis of the degree of irritation were treated by Keraskin$^{TM}$ test. The percent of cell viability was measured into the culture medium collected after treatment of the pesticides for 24-72 hrs. The skin irritations of formulations were evaluated by the cell viability. In this study, The 4 formulations with mild irritation in rabbits were evaluated as nonirritant, the 6 formulations with moderate and severe irritation were evaluated as irritant in human skin model test. We suggest that the alternative test using Keraskin$^{TM}$ model could be used as toxicity evaluation for primary irritation index (P.I.I.) score of greater than or equal to 2.1 of pesticides. The further studies should be required to apply for hazardous assessment of pesticides on alternative skin irritation methods because of the interindividual variability of the sensitivity of skin irritation on pesticides.

Field Tests for Assessing the Bioremediation Feasibility of a Trichloroethylene-Contaminated Aquifer (관측정 자연표류 실험을 통한 트리클로로에틸렌(Trichloroethylene) 오염 지하수의 생물학적 복원 타당성 연구)

  • Kim Young;Kim Jin-Wook;Ha Chul-Yoon;Kim Nam-Hee;Hong Kwang-Pyo;Kwon Soo-Yul;Ahn Young-Ho;Ha Joon-Su;Park Hoo-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.38-45
    • /
    • 2005
  • The feasibility of stimulating in situ aerobic cometabolic activity of indigenous microorganisms was investigated in a trichloroethylene (TCE)-contaminated aquifer. A series of single-well natural drift tests (SWNDTs) was conducted by injecting site groundwater amended with a bromide tracer and combinations of toluene, oxygen, nitrate, ethylene and TCE into an existing monitoring well and by sampling the same well over time. Three field tests, Push-pull Transport Test, Drift Biostimulation Test, and Drift Surrogate Activity Test, were performed in sequence. Initial rate of toluene degradation was much faster than the rate of bromide dilution resulting from natural groundwater drift, indicating stimulation of indigenous toluene-oxidizing microorganisms. Transformation of ethylene, a surrogate probing overall activity of TCE transformation, was also observed, and its transformation results in the production of ethylene oxide, suggesting that some tolueneoxidizing microorganisms stimulated may express a orthomonooxygenase enzyme. Also in situ transformation of TCE was confirmed by greater retardation of TCE than bromide after the stimulation of toluene-oxidizing microorganisms. These results indicate that, in this environment, toluene and oxygen additions stimulated the growth and aerobic cometabolic activity of indigenous microorganisms expressing orthomonooxygenase enzymes. The simple, low-cost field test method presented in this study provides an effective method for conducting rapid field assessments and pilot testing of aerobic cometabolism, which has previously hindered application of this technology to groundwater remediation.

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Use of Chicken Meat and Processing Technologies (가금육의 이용과 가공기술)

  • Ahn, Dong-Uk
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.07b
    • /
    • pp.67-88
    • /
    • 2003
  • The consumption of poultry meat (chicken and turkey) grew the most during the past few decades due to several contributing factors such as low price. product research and development. favorable meat characteristics, responsive to consumer needs, vertical integration and industry consolidation, new processing equipments and technology, and aggressive marketing. The major processing technologies developed and used in chicken processing include forming/restructuring, tumbling, curing, smoking, massaging, injection, marination, emulsifying, breading, battering, shredding, dicing, and individual quick freezing. These processing technologies were applied to various parts of chicken including whole carcass. Product developments using breast, thigh, and mechanically separated chicken meat greatly increased the utilization of poultry meat. Chicken breast became the symbol of healthy food, which made chicken meat as the most frequent menu items in restaurants. However, the use of and product development for dark meat, which includes thigh, drum, and chicken wings were rather limited due to comparatively high fat content in dark meat. Majority of chicken are currently sold as further processed ready-to-cook or ready-to-eat forms. Major quality issues in chicken meat include pink color problems in uncured cooked breast, lipid oxidation and off-flavor, tenderness PSE breast, and food safety. Research and development to ensure the safety and quality of raw and cooked chicken meat using new processing technologies will be the major issues in the future as they are now. Especially, the application of irradiation in raw and cooked chicken meat products will be increased dramatically within next 5 years. The market share of ready-to-eat cooked meat products will be increased. More portion controlled finished products, dark meat products, and organic and ethnic products with various packaging approaches will also be introduced.

  • PDF

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method (Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰)

  • Lee, Juyoung;Nam-Kung, Sik;Kim, Ji-Hyeon;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

  • PDF

Comparison of Patency and Viability in Fresh and Cryopreserved Arterial and Venous Allograft Conduits in Dogs (개에서 동맥과 정맥 동종 이식편의 냉장, 보존 방법에 따른 개존율 및 생육성에 관한 연구)

  • Song, Hyun;Kang, Shin-Kwang;Ryu, Yang-Gi;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.149-159
    • /
    • 2008
  • Background: With increasing coronary bypass and peripheral vascular surgeries, the demand for homologous vascular or synthetic conduits has continued to grow, but wide-spread application has been limited by dismal patency rates. Although cryopreserved allograft valves may provide a suitable alternative, current viability or patency of implanted allograft vascular conduits has been unsatisfactory. Material and Method: We serially analyzed the outcomes of canine femoral artery and saphenous vein allograft implants after storage in either $4^{\circ}C\;or\;-170^{\circ}C$. Result: There were no differences in graft flow rate (patency) (p=0.264), rate of thrombosis (p=0.264), presence of endothelium (p=0.587), or immunohistochemical staining for thrombomodulin (p=0.657) were detected between grafts stored in $4^{\circ}C\;and\;-170^{\circ}C$. Greater flow occurred in the arterial grafts versus the venous grafts (p=0.030), irrespective of the preservation method, with a significantly lower incidence of thrombosis (p=0.030) in arterial allografts. There was a correlation coefficient of -0.654 between thrombosis and positive immunohistochemical staining for thrombomodulin (p=0.006) and a correlation coefficient of 0.520 (p=0.0049) between the endothelial presence and positive immunohistochemical staining for thrombomodulin. The relationship between the presence of endothelium and thrombomodulin expression failed to show any correlation within the first 2 weeks (p=0.306). However, a strong correlation was seen after 1 month (p=0.0008). Conclusion: Tissue storage in either $4^{\circ}C\;or\;-170^{\circ}C$ in 10% DMSO/RPMI-1640 preservation solution preserved grafts equally well. In terms of thrombosis and graft patency, arterial grafts were superior to venous grafts. Considering the poor correlation between thrombomodulin expression and the presence of an endothelium in the implanted graft within the first two weeks, grafts in this period would not be thromboresistant.

Application for Identification of Food Raw Materials by PCR using Universal Primer (일반 프라이머를 이용한 PCR의 식품원료 진위 판별에 적용)

  • Park, Yong-Chjun;Jin, Sang-Ook;Lim, Ji-Young;Kim, Kyu-Heon;Lee, Jae-Hwang;Cho, Tae-Yong;Lee, Hwa-Jung;Han, Sang-Bae;Lee, Sang-Jae;Lee, Kwang-Ho;Yoon, Hae-Seong
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.317-324
    • /
    • 2012
  • In order to determine an authenticity of food ingredient, we used DNA barcode method by universal primers. For identification of animal food ingredients, LCO1490/HCO2198 and VF2/FISH R2 designed for amplifying cytochrome c oxidase subunit1 (CO1) region and L14724/H15915 for cytochrome b (cyt b) region on mitochondrial DNA were used. Livestock (cow, pig, goat, sheep, a horse and deer) was amplified by LCO1490/HCO 2198, VF2/FISH R2 and L14724/H15915 primers. Poultry (chicken, duck, turkey and ostrich) was amplified by LCO1490/HCO 2198 and VF2/FISH R2 primers. But, Fishes (walleye pollack, herring, codfish, blue codfish, trout, tuna and rockfish) were only amplified by VF2/FISH R2 primers. For plant food ingredients, 3 types of primers (trnH/psbA, rpoB 1F/4R and rbcL 1F/724R) have been used an intergenic spacer, a RNA polymerase beta subunit and a ribulose bisphosphate carboxylase region on plastid, respectively. Garlic, onion, radish, green tea and spinach were amplified by trnH/psbA, rpoB 1F/4R and rbcL 1F/724R. The PCR product sizes were same by rpoB 1F/4R and rbcL 1F/724R but, the PCR product size using trnH/psbA primer was different with others for plants each. We established PCR condition and universal primer selection for 17 item's raw materials for foods and determine base sequences aim to PCR products in this study. This study can apply to determine an authenticity of foods through making an comparison between databases and base sequences in gene bank. Therefore, DNA barcode method using universal primers can be a useful for species identification techniques not only raw materials but also processed foods that are difficult to analyze by chemical analysis.