Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method

Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰

  • Lee, Juyoung (Graduate School of Public Health, Yonsei University) ;
  • Nam-Kung, Sik (Department of Nuclear Medicine, Konkuk University Medical Center) ;
  • Kim, Ji-Hyeon (Department of Nuclear Medicine, Seoul Medical Center) ;
  • Park, Hoon-Hee (Department of Radiological Technology, Shingu College)
  • Received : 2014.03.28
  • Accepted : 2014.04.21
  • Published : 2014.05.23

Abstract

Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

PET 영상의 질 향상과 더불어 많은 연구를 통해 다양한 프로그램의 개발이 이루어지고 있다. 그 중 Philips 사의 Astonish TF 재구성 기법은 기존보다 빠른 재구성 속도와 함께 2 mm의 영상 재구성이 가능하여 병변의 향상된 대조도를 확인할 수 있다. 본 연구에서는 전신 $^{18}F-FDG$ PET 영상에서 기존의 4 mm와 2 mm 재구성 기법에 따른 표준섭취계수(SUV)를 비교 평가하였다. GEMINI TF 64 PET/CT (Philips, Cleveland, USA)를 사용하여 팬텀실험은 NEMA IEC Body Phantom (sphere: 10, 13, 17, 22, 28, 37 mm)으로 영상을 획득하였고, 임상영상은 유방암 진단을 받은 여자 30명(연령: $55.1{\pm}11.3$세, BMI: $24.1{\pm}2.9$)을 대상으로 $^{18}F-FDG$ PET/CT 검사를 시행한 후, 각각 4 mm와 2 mm로 영상을 재구성하였다. 획득된 영상은 EBW (Extended Brilliance Workstation) NM ver.1.0을 통해 팬텀과 임상영상에 관심영역을 설정하고, 표준섭취계수를 측정하였으며, SPSS ver.17.로 통계 분석하였다. 팬텀실험에서 90 sec로 획득한 영상의 4 mm와 2 mm 재구성 영상의 $SUV_{Max}$를 비교한 결과, 열소의 크기가 작을수록 $SUV_{Max}$의 편차가 크게 나타났고, 150 sec로 획득한 영상의 4 mm와 2 mm 재구성 영상의 $SUV_{Max}$를 비교한 결과에서도 같은 성향을 나타냈다. 90 sec와 150 sec로 획득한 영상의 $SUV_{Max}$의 편차 정도는 90 sec로 영상을 획득하였을 경우 보다 150 sec로 획득한 영상에서 열소의 크기가 작을수록 큰 차이를 나타냈고, 열소의 크기가 클수록 작은 차이를 나타냈다. 임상영상에서는 4 mm와 2 mm 재구성 기법을 분석한 결과, 표준섭취계수는 4 mm보다 2 mm 재구성 기법에서 높게 나타났고, 또한 체적이 작을수록 변화율이 증가하였다. Astonish TF 재구성 기법을 적용한 팬텀실험과 임상영상의 분석 결과, 체적의 크기가 작을수록 표준섭취계수의 변화율이 증가하였다. 그러므로 임상에서 대조도 및 병변 감별력이 우수한 2 mm 재구성 기법의 정확하고 적극적인 활용을 위하여 표준섭취계수 보정에 대한 추가적인 연구가 필요할 것으로 사료된다.

Keywords